4.3 Battery replacement
EXPLOSION HAZARD:
The unit must be
powered OFF during the battery installation & must
be in a General Purpose Classified Area to prevent
the possible ignition of a hazardous atmosphere.
WARNING STATIC HAZARD:
Wipe only with
a damp cloth due to electrostatic discharge hazard.
The substitution of components may
impair intrinsic safety.
Power is provided by a lithium battery pack (S1-
1061), located in the inner portion of the transmitter
housing. Battery life is dependent upon data
transmittal intervals. Battery voltage should
normally be between 2.8 and 3.6 VDC. If it is lower
than this, the battery will need to be replaced. The
battery voltage can be read at the receiver or
through the PSP software when connected directly
to the SELD-102 Node unit (refer to PSP software
user instructions for details on how to do this).
The battery pack is
NOT
re-chargeable and
shall only be replaced by contacting your local
sales representative (Battery pack part number S1-
xxxx).
Perform the following steps to replace the battery:
1. Take the unit to a general purpose area.
2. Power down unit by unplugging the battery.
Figure 3: SELD-102 Node unit battery (with unit
external housing removed)
Figure 4: SELD-102 Node unit battery nuts
holding battery in place
6.
Install new battery pack (part number
S1-1061). Reinstall battery mounting nuts,
reconnect battery pack connector.
7. Install tube back onto unit and tighten tube
8. Reinstall SELD-102 Node unit in the field.
9. Dispose of old battery pack in accordance with
instructions in section 2.5 Disposal
instructions.
5 CUSTOM CONFIGURATION
PROGRAMMING
This section is optional. As long as your
specific application was communicated to the
factory prior to shipment, the SELD-102 Node unit
is pre-configured for your specific use.
Errors in programming
configuration can render the SELD-103 unit
inoperable, proceed with caution. Flowserve is
not liable for any damage caused by user
configuration errors.
For instructions on how to change software
configuration options on the SELD-102 Node unit,
refer to the separate PSP software user
instructions. The list below provides an overview of
the functions that can be performed using this
software utility:
-
Read & save SELD-102 Node
configuration
-
View & modify SELD-102 Node
transmission intervals
-
Setting alarm threshold values
-
Calibration of individual sensors on SELD-
102 Node unit
-
Read live data from sensors on the SELD-
102 Node unit
-
Turn specific SELD-102 Node sensor
channels on or off
Battery
wires
Nuts holding
battery
Содержание IPS Wireless SELD-102
Страница 18: ...IPS WIRELESS SELD 102 Node ENGLISH 702 3001 07 17 Page 18 of 22 flowserve com ...
Страница 19: ...IPS WIRELESS SELD 102 Node ENGLISH 702 3001 07 17 Page 19 of 22 flowserve com ...
Страница 20: ...IPS WIRELESS SELD 102 Node ENGLISH 702 3001 07 17 Page 20 of 22 flowserve com ...
Страница 21: ...IPS WIRELESS SELD 102 Node ENGLISH 702 3001 07 17 Page 21 of 22 flowserve com ...