background image

5

4  

Operational Recommendations for Single Cartridge Seal 

4.1    Do not start up the equipment dry. Vent air from the casing of the pump and the seal chamber 

before startup. Check the seal assembly drawing for the recommended piping plan and follow 
any special instructions. Plan 11 is a good default flush plan if none are specified for horizontal 
pumps.

4.2    If the seal runs hot, check for proper seal setting, seal housing dimensions, and check the 

bypass or flush line for obstructions. Do not allow the equipment to run for any extended time 
if the seal gets hot or squeals.

5  

Operational Recommendations for Dual Cartridge Seal

5.1    A dual seal must be supplied a clean buffer/barrier fluid compatible with the product. 
5.2 

Dual pressurized seals must at all times maintain barrier fluid pressure at least 1.7 bar  
(25 psig) above the maximum product pressure in the seal chamber. 

5.2    The recommended piping for a dual pressurized seal with the use of a Supply Tank is shown  

in Figure 8, Plan 53A. Circulation from an external source is shown in Figure 9, Plan 54.  
Other mechanical seal support systems are also available from Flowserve. 

5.3 

Turn on any cooling water to the supply tank or other support system.

5.4 

Start-up the seal barrier fluid system before starting pump.  

5.5   Do not start up the equipment dry. Vent air from the casing of the pump before startup.
5.6   If the seal runs hot, check for proper seal setting, seal housing  

 

dimensions, and check the barrier fluid system. Do not allow the equipment to run for  
any extended time if the seal gets hot or squeals.

For special problems encountered during installation, contact your nearest Flowserve Sales and 
Service Representative or Flowserve Authorized Distributor.

outlet

inlet

pressure source,

normally open

pressure 

transmitter

level 

transmitter

cooling coils

cooling in

drain, 

normally 

closed

cooling out

reservoir

liquid fill, 

normally closed

level indicator

seal 

end view

orifice

outlet

inlet

from / to external

pressurized barrier  

circulating system

seal 

end view

Plan 53A - Dual pressurized seal with  
circulation through a supply tank

         

Figure 8

Plan 54 - Dual seal circulation  

 

from an external source

                   

Figure 9

Содержание HSH Series

Страница 1: ...ting sealing arrangement mechanical seal or otherwise Clean seal chamber and shaft thoroughly 1 4 Inspect surfaces under gaskets to ensure they are free from pits or scratches Break all sharp corners...

Страница 2: ...h If equipment is found outside the general range contact the equipment manufacturer and your Flowserve representative to verify the equipment s suitability for the seal Seal chamber squareness to the...

Страница 3: ...tion pumps Adjust the bearings coupling and impeller so that the shaft is in its operating axial position 2 9 Tighten the set screws on the seal cartridge drive collar See Section 3 if your seal is eq...

Страница 4: ...Flowserve supplied or approved grease CAUTION Do not use grease or oil on the sleeve or shaft to aid in installation 3 5 2 The seal sleeve should install easily over the equipment shaft if resistance...

Страница 5: ...8 Plan 53A Circulation from an external source is shown in Figure 9 Plan 54 Other mechanical seal support systems are also available from Flowserve 5 3 Turn on any cooling water to the supply tank or...

Страница 6: ...must be de pressurized and drained Operator must persuade himself before starting disassembling of mechanical seal that the external of the equipment is cool enough to be handled without risk Barrier...

Страница 7: ...ion sealing device The design and dimensional tolerances are critical to seal performance Only parts supplied by Flowserve should be used to repair this seal These are available from the numerous Flow...

Страница 8: ...information and specifications contained in this literature are believed to be accurate they are supplied for informative purposes only and should not be considered certified or as a guarantee of sat...