00     No switches 
 

  (empty housing) 

 

F1     

IFM 

IN5129 

10-36VDC (J=14only)

F3      

IFM 

IF5250  

10-36VDC NC PNP, 150mA, 3-wire NC

F5     

IFM 

IF6001  

18-32VDC, NO PNP, 150mA@50°C

F6     

IFM 

IF6034  

10-36VDC, NO PNP, 150mA, Stainless Steel

F7     

IFM 

IN0074 

20-250 AC/DC NO, 350mA/100mA

F8     

IFM 

IN0081 

20-250 AC/DC NO, 350mA/100mA w/LED (J=14)

F9     

IFM 

IN0097 

20-250 AC/DC NO   

 

FB 

 

  IFM 

IF5249 

10-36VDC NO PNP, 150mA, 3-wire NO

FC     

IFM 

IF5718  

10-36VDC NO PNP/NPN, 150mA, plastic

FE      

IFM 

NS5003 

IS-2002-N

FG    

IFM 

IS5070 

FB3004-APKG

FH    

IFM 

IS5001 

IS-3002-BPOG

FJ     

IFM 

IN5263 

IN-2002-FRKG/PH RT

FK    

IFM 

NS5002 

IS-2002-N

FZ    AS-i Bus Card 

 

 

31VDC 28 mA

M1     SPDT  

Honeywell 

V7-1C13D8-201 

15.1A (1/2 HP) at 125/250 VAC; 1/4A at 125 VDC; 

 

  Mechanical 

MicroSwitch 

 

1/4A at 250 VDC; 5A at 120 VAC (resistive load)

MG    SPDT  

Honeywell 

V7-1D19D8-201 

1A at 125 VAC / 50 mA at 24 VDC

 

  Gold Mechanical 

MicroSwitch 

 

(resistive load)

N1      

Fuchs

 NJ4-12GM40-E

N2      

Fuchs

 NJ2-12GK-N

N3      

Fuchs

 SJ3,5-S1N

N4    

Fuchs

 NJ2-12GK-SN

N5     

Fuchs

 NJ4-12GK40-E

N6    

Fuchs

 NJ4-12GK40-E1

N7      

Fuchs

 NBB2-V3-E0

N8     Solid State Proximity  Fuchs 

NJ2-V3-N 

NAMUR Sensor Output / 5-25 VDC Supply

N9     Solid State Proximity  Fuchs 

NBB3-V3-Z4 

NPN Sourcing/ 100 mA max. Current /   5-60 VDC

NA     

Fuchs

 NBN4-12GM40-E2

NB     

Fuchs

 NJ2-12GM-N

NC     

Fuchs

 NJ4-12GM-N

ND     

Fuchs

 NCB2-12GM40-Z1

NE    

Fuchs

 NCB2-12GM35-N0

NF      

Fuchs

 NCN4-12GM35-N0

NG    

Fuchs

 NJ5-11-N-G

NH    

Fuchs

 NCB4-12GM40-N0

NK      

Fuchs

 NCN4-12GM40-Z0

NL      

Fuchs

 NCB2-V3-N0

NM      

Fuchs

 NJ2-11-SN-G

NN      

Fuchs

 NBB2-V3-E2

NP     Solid State Proximity  Fuchs 

SJ3.5-N

NQ      Solid State Proximity  Fuchs 

NJ4-12GK-N 

NR      Solid State Proximity  Fuchs 

NJ4-12GM40-E1 

PNP Sinking / 200 mA max. Current / 10-60 VDC 

7.5 Switch option specifications (all)

Code       Switch Option           Manufacturer       Part Number             Load Capacity

FCD ACENIM0135-02 - 09/16

Содержание Accord WS/WM Ultraswitch

Страница 1: ...USER INSTRUCTIONS Installation Operation Maintenance FCD ACENIM0135 02 09 16 Accord WS WM Ultraswitch Switchbox...

Страница 2: ...enclature 5 5 5 WS WM UltraSwitch switch options 6 6 INSTALLATION 8 6 1 Wiring instructions 9 6 2 Cover and housing options 10 7 SWITCHES Certified 11 7 1 Installation in hazardous locations 11 7 2 Ad...

Страница 3: ...2 locations Inspect periodically for degradation Replace parts if degradation is found Cleaning this housing by rubbing should be done in a non hazardous area Potential electrostatic charging hazard c...

Страница 4: ...berglass filled or Transparent Polycarbonate Shaft Stainless Steel SS EN 2346 AISI 303 Cams Splines Nylon Terminal Block Nylon Internal Brackets Nylon Aluminum or Stainless Steel All Internal Fastener...

Страница 5: ...Conduit entries D Number of conduit entries 2 2 conduit entries 4 4 conduit entries 2 according to C entries opposite side with different type of th reading E Body material A Aluminum R Engineered res...

Страница 6: ...VAC 0 25A 200VDC 50 W Max P5 A B C SPDT Proximity Hamlin 0 25A 120 VAC 0 25A 28 VDC 3 W Max PE A B C SPDT Sabre Proximity Flowserve 1A 120 VAC 1A 24 VDC PP C SPDT Phazer Proximity Flowserve 3A 120 VAC...

Страница 7: ...S WM Nomenclature on page 5 2 Some models have more than two open terminal locations open as standard Consult factory for details Code Certificate A ATEX II 1GD Ex ia IIC T4 T5 T6 ATEX II 1GD Ex ia II...

Страница 8: ...direct coupling to actuators without couplings reducing dead band Bolt bracket to actuator and WS WM Ultraswitch to bracket leaving bolts finger tight For NAMUR applications the WS WM Ultraswitch swi...

Страница 9: ...clockwise position the bottom switch should only be used to indicate the counter clockwise position Any deviation from these settings may result in erratic indication Solenoids may also be wired thro...

Страница 10: ...minum housing Resin housing Aluminum or Resin cover Arrow Indicator Polycarbonate transparent cover Arrow Indicator Polycarbonate transparent cover Dome Indicator Aluminum or Resin cover flat 6 2 Cove...

Страница 11: ...ust cam s as sociated with CW as follows 1 Push or pull cam against spring to disengage it from splines 2 Rotate cam CW breaking contact with switch or moving magnet away from switch 3 Continue rotati...

Страница 12: ...erl Fuchs NJ4 12GM40 E N2 Pepperl Fuchs NJ2 12GK N N3 Pepperl Fuchs SJ3 5 S1N N4 Pepperl Fuchs NJ2 12GK SN N5 Pepperl Fuchs NJ4 12GK40 E N6 Pepperl Fuchs NJ4 12GK40 E1 N7 Pepperl Fuchs NBB2 V3 E0 N8 S...

Страница 13: ...2 V3 E3 NY Solid State Proximity Pepperl Fuchs NJ4 12GK SN NAMUR Sensor Output 5 25 VDC Supply P4 SPST Proximity Aleph PS 6132 0 35A at 140 VAC 25A at 200VDC 50 W Max P5 SPDT Proximity Hamlin 59135 03...

Страница 14: ...14 8 Dimensions WS body enclosure WM body enclosure FCD ACENIM0135 02 09 16...

Страница 15: ...67 Gasket for cover all cover types 1 2 3 4 5 The Rotary Limit Switch Box is marked with the following warning marking WARNING POTENTIAL ELECTROSTATIC CHARGING HAZARD SEE INSTRUCTIONS Enclosure materi...

Страница 16: ...t Locator System found at www flowserve com Flowserve Corporation has established industry leadership in the design and manufacture of its products When properly selected this Flowserve product is des...

Отзывы: