background image

8

Flow Control

Kämmer Control Valves

®

regional Headquarters

Flowserve eMa 

Flowserve america 

Flowserve asia

Burrell Road, Hayward Heath 

350 N. Mt. Springs Prkwy. 

2 Tuas Avenue 20

West Sussex, RH6 TL 

Springville, UT 84663 

638824 

England 

USA 

Republic of Singapore 

Telephone: +44 (0) 444 34400 

Telephone: + 80 489 86 

Telephone: +65 862 3332

Facsimile: +44 (0) 44 34440 

Facsimile: + 80 489 379 

Facsimile: +65 862 4940

Main sales Offices eMa (europe, Middle east, africa)

Flowserve France 

Flowserve switzerland 

Flowserve germany 

Flowserve eastern europe

7 Avenue de la Libération 

Allee du Quartz  

Manderscheidtstr. 9 

2, av. du Québec

63300 Thiers Cedex 

CH-2300 La-Chaux-de Fonds 

454 Essen 

9965, Courtaboeuf Cedex

France 

Switzerland 

Germany 

France

Telephone: +33 (0) 4 73 80 42 66 

Telephone: +4 (0) 32 925 9700 

Telephone: +49 (0) 20 899 5 

Telephone: +33 (0)  60 923 25

Facsimile: +33 (0) 4 73 80 4 24 

Facsimile: +4 (0) 32 926 5422 

Facsimile: +49 (0) 20 899 662 

Facsimile: +33 (0)  60 923 299

Flowserve south africa 

Flowserve Middle-east 

Flowserve austria 

Flowserve benelux

Unit  

C/O Saleh & Abdulaziz Abahsain 

Kasernengasse 6 

Van Leeuwenhoekweg 6 

 

2 Director Road 

P.O. Box 209 

 

Spartan Ext 2, Kempton park 

 

 

Gauteng 

Al Khobar 3952 

9500 Villach 

3225 LX Hellevoetsluis

South Africa 

Saudi Arabia 

Austria 

The Netherlands

Telephone: +27  923 7300 

Telephone: 9663 857 3442 

Telephone: +43 (0) 42424 8-0 

Telephone: +3 (0) 8 330044 

Facsimile: +27  974 6420  

Facsimile: 9663 859 5284 

Facsimile: +43 (0) 42424 8 50/5  Facsimile: +3 (0) 8 330040

Flowserve Italy 

Flowserve spain 

Flowserve Portugal 

Flowserve scandinavia

Via Prealpi, 30 

Luis Cabrera, 86-88 

Av. Dr. Antunes Guimaraes, 59 

Gelbgjutaregatan

Cormano (Milano) 

E-28002 Madrid 

Porto 400-082 

58933 Linköping, Östergötland

Italy 

Spain 

Portugal 

Sweden

Telephone: +39 (0) 266325 

Telephone: +34 9 5 52 032 

Telephone: +35 22 69 8770 

Telephone: +46 3 3600

Facsimile: +39 (0) 265863 

Facsimile: +34 9 4 36 747 

Facsimile: +35 22 69 7575 

Facsimile: +46 3 36054

 trouble-shooting chart

 Fault   

 Possible cause 

remedy

Stem motion  

. Packing excessively tightened  

. Tighten gland nut slightly more than „finger-tight“

impeded 

2. Operating temperature too 

2. Note operating data and contact dealer 

  

     high for selected trim

  

3. Supply pressure inadiquate  

3. Check system for leaks in the supply pressure or signal lines. Re- 

 

 

  

 

tighten the connections, if necessary replace leaky lines

  

4. Positioner defective 

4. See operating instructions for positioner

Excessive 

. Bonnet loose 

. See step 7.2.6 for correct tightening of bonnet.

leakage 

2. Worn or damaged  

2. Re-machine or replace seat ring/plug.

  

    seat ring/plug

  

3. Gaskets damaged 

3. Replace gaskets

  

4. Inadiquate actuator thrust 

4. Check air feed. If air feed is OK, contact dealer.

  

5. Plug incorrectly adjusted 

5. Correctly adjust plug according to step 6.2.4

  

6. Incorrect direction of flow 

6. Check specification. Contact dealer

  

7. Handwheel incorrectly 

7. Adjust handwheel

  

adjusted (acts like end stop)

Inadiquate flow 

. Plug incorrectly adjusted 

. Correctly adjust plug according to step 6.2.4

  

    (short stroke)  

 

  

2. Positioner defective 

2. See operating instructions for positioner

  

3. Operating requirements  

3. Check operating data. Contact dealer

  

    too high

Plug slams 

. Plug adjustment incorrect 

. Correctly adjust plug according to step 6.2.4

  

2. Inadiquate supply pressure 

2. Check supply pressure, seal leaks, remove blockage

  

3. Trim too large for 

3. Replace trim 

 

  

    flow rate

All data subject to change without notice

©09.2003 Flowserve Corporation. Flowserve and Kämmer are trademarks of Flowserve Corporation 

Содержание 035 000 Series

Страница 1: ...ith regard to transport assembly operation and maintenance and with regard to technical documentation e g in the operating instruction product documentation or on the product itself is essential in or...

Страница 2: ...Fire protection for K mmer products must be provided by the end user 1 7 Service repair To avoid possible injury to personnel or damage to products safety terms must be strictly adhered to Modifying t...

Страница 3: ...or corrosive vapours 5 4 Clean valves and repaint as necessary Warning To prevent a buildup of electrostatic charge clean the actuator valve with a damp cloth only 5 5 Check gland nut for correct tor...

Страница 4: ...upling Coupling screws Coupling insert Locknut Yoke plate Yoke nuts Actuator series 2 Fig 1a Zero adjustment locknut Actuator stem Travel indicator Yoke plate Yoke nuts Cap Locknuts Gland nut Clamping...

Страница 5: ...using and the actuator is aligned forward If the actuator is fitted with a coupling refer to the procedure described in the maintenance instructions for the I P actuator NOTE Ensure that the plug asse...

Страница 6: ...ves Packing kit see spare parts list Trim see spare parts list Locknut Gland nut Packing follower Clamping nut Nut Bonnet Bolt stud depends on design Gasket Body Bore for adjustable face pin tool Fig...

Страница 7: ...sembled lapping is not required NOTE When re machining the plug protect plug stem from damage The seat surface must be concentric to the plug stem When re finishing the seat the seat surface must be c...

Страница 8: ...rmano Milano E 28002 Madrid Porto 4100 082 58933 Link ping sterg tland Italy Spain Portugal Sweden Telephone 39 0 2663251 Telephone 34 9 15 152 032 Telephone 351 22 619 8770 Telephone 46 13 316100 Fac...

Отзывы: