SAFETY

 

PRECAUTIONS

 

Step

 

Three

 

 

About

 

This

 

Manual:

  

PLEASE

 

READ

 

THE

 

ENTIRE

 

MANUAL

 

PRIOR

 

TO

 

INSTALLING

 

OR

 

USING

 

THIS

 

PRODUCT.

 

This

 

manual

 

includes

 

information

 

on

 

three

 

different

 

models

 

of

 

Remote

 

Relay

 

Flow

 

Controllers

 

from

 

FLOWLINE:

 

LC80

 

and

 

LC82

 

series.

   

Many

 

aspects

 

of

 

installation

 

and

 

use

 

are

 

similar

 

between

 

the

 

three

 

models.

  

Where

 

they

 

differ,

 

the

 

manual

 

will

 

note

 

it.

  

Please

 

refer

 

to

 

the

 

part

 

number

 

on

 

the

 

controller

 

you

 

have

 

purchased

 

as

 

you

 

read.

 

 

User’s

 

Responsibility

 

for

 

Safety:

   

FLOWLINE

 

manufactures

 

several

 

models

 

of

 

controller,

 

with

 

different

 

mounting

 

and

 

switching

 

configurations.

  

It

 

is

 

the

 

user’s

 

responsibility

 

to

 

select

 

a

 

controller

 

model

 

that

 

is

 

appropriate

 

for

 

the

 

application,

 

install

 

it

 

properly,

 

perform

 

tests

 

of

 

the

 

installed

 

system,

 

and

 

maintain

 

all

 

components.

 

 

Electrical

 

Shock

 

Hazard:

   

It

 

is

 

possible

 

to

 

contact

 

components

 

on

 

the

 

controller

 

that

 

carry

 

high

 

voltage,

 

causing

 

serious

 

injury

 

or

 

death.

  

All

 

power

 

to

 

the

 

controller

 

and

 

the

 

relay

 

circuit(s)

 

it

 

controls

 

should

 

be

 

turned

 

OFF

 

prior

 

to

 

working

 

on

 

the

 

controller.

   

If

 

it

 

is

 

necessary

 

to

 

make

 

adjustments

 

during

 

powered

 

operation,

 

use

 

extreme

 

caution

 

and

 

use

 

only

 

insulated

 

tools.

  

Making

 

adjustments

 

to

 

powered

 

controllers

 

is

 

not

 

recommended.

  

Wiring

 

should

 

be

 

performed

 

by

 

qualified

 

personnel

 

in

 

accordance

 

with

 

all

 

applicable

 

national,

 

state

 

and

 

local

 

electrical

 

codes.

 

 

Flammable

 

or

 

Explosive

 

Applications

:

 

 

The

 

entire

 

LC80

 

series

 

remote

 

mount

 

controllers

 

should

 

not

 

be

 

used

 

with

 

explosive

 

or

 

flammable

 

liquids,

 

which

 

require

 

an

 

intrinsically

 

safe

 

or

 

explosion

 

proof.

  

If

 

you

 

are

 

unsure

 

of

 

the

 

suitability

 

of

 

a

 

controller

 

for

 

your

 

installation,

 

consult

 

your

 

Flowline

 

representative

 

for

 

further

 

information.

  

 

Install

 

In

 

a

 

Dry

 

Location:

  

The

 

controller

 

housing

 

is

 

not

 

designed

 

to

 

be

 

immersed.

  

When

 

installed

 

properly,

 

it

 

should

 

be

 

mounted

 

in

 

such

 

a

 

way

 

that

 

it

 

does

 

not

 

normally

 

come

 

into

 

contact

 

with

 

liquid.

  

Refer

 

to

 

an

 

industry

 

reference

 

to

 

ensure

 

that

 

compounds

 

that

 

may

 

splash

 

onto

 

the

 

controller

 

housing

 

will

 

not

 

damage

 

it.

  

Such

 

damage

 

is

 

not

 

covered

 

by

 

the

 

warranty.

 

 

Relay

 

Contact

 

Rating:

  

The

 

relay

 

is

 

rated

 

for

 

a

 

10

 

amp

 

resistive

 

load.

  

Many

 

loads

 

(such

 

as

 

a

 

motor

 

during

 

start

up

 

or

 

incandescent

 

lights)

 

are

 

reactive

 

and

 

may

 

have

 

an

 

inrush

 

current

 

characteristic

 

that

 

may

 

be

 

10

 

to

 

20

 

times

 

their

 

steady

state

 

load

 

rating.

   

The

 

use

 

of

 

a

 

contact

 

protection

 

circuit

 

may

 

be

 

necessary

 

for

 

your

 

installation

 

if

 

the

 

10

 

amp

 

rating

 

does

 

not

 

provide

 

an

 

ample

 

margin

 

for

 

such

 

inrush

 

currents.

 

Components:

  

Part

 

Number

 

VAC

 

Configuration

 

CSA

 

Approval

 

Inputs

 

Output

 

LC80

1001

 

120

 

Yes

 

Single

 

Single

 

Relay

 

LC80

1001

E

 

240

 

LC82

1001

 

120

 

Dual

 

Dual

 

Relay

 

LC82

1001

E

 

240

 

 

Owner’s

 

Manual

 

 

 

Содержание Thermo-Flo LC80 Series

Страница 1: ...Rev B MN301530 1 of 14 Thermo Flo Remote Flow Controller LC80 LC82 Series Manual Flowline Inc 10500 Humbolt Street Los Alamitos CA 90720 Tel 562 598 3015 Fax 562 431 8507 www flowline com...

Страница 2: ...to 60 second delay Easy setup with LED indicators for sensor s power and relay status 35mm DIN rail mount polypropylene enclosure with removable terminal strips Invert switch changes relay state from...

Страница 3: ...tact delay 0 to 60 seconds Electronics temp F 40 to 158 C 40 to 70 Enclosure rating 35mm DIN EN 50 022 Enclosure material PP U L 94 VO Fail safety Power fail safe Classification General purpose Approv...

Страница 4: ...mmended Wiring should be performed by qualified personnel in accordance with all applicable national state and local electrical codes Flammable or Explosive Applications The entire LC80 series remote...

Страница 5: ...nt sensor technologies where possible While this manual offers some examples and suggestions to help explain the operation of FLOWLINE products such examples are for information only and are not inten...

Страница 6: ...oad of not more than 10 amps for reactive loads the current must be derated or protection circuits used When the red LED is ON and the relay is in the energized state the NO terminal will be closed an...

Страница 7: ...C will be used in different applications Remember that the normal state is when the relay coil is de energized and the Red relay LED is Off de energized Both terminals share the Common C terminal When...

Страница 8: ...hite can also be wired to the flow controller See the illustration below to indicate wiring for your switch and the polarity of the switch output Note the Shield wire will be used only for long cable...

Страница 9: ...whether the switch is in a Flow or No Flow state With the flow switch wired NC the Amber LED indicates No Flow and no LED indicates flow Wiring the switch NO reversing the Red and Black wires the Ambe...

Страница 10: ...and the relay LED will be ON So for this wiring configuration Invert should be set to the ON position If the switch is wired NO the input LED and the relay LED will be ON simultaneously So for this w...

Страница 11: ...le through the potentiometer If the LED is on slowly adjust the potentiometer counterclockwise with a small flat head screwdriver until the LED turns off The adjustment is a single turn 270 potentiome...

Страница 12: ...hat relay click on and off as well as the relay LED The Flow or No Flow is not switching at the correct flow rate The flow switch may need to be adjusted Review the Flow Switch Calibration section on...

Страница 13: ...r auto empty applications The only change is that the relay will energize when the top is wet bottom is also wet and de energize when the bottom is dry top is also dry In both scenarios when the level...

Страница 14: ...ocedures outlined above 2 have been subjected to electrical mechanical or chemical damage due to improper accidental or negligent use 3 have been modified or altered 4 anyone other than service person...

Отзывы: