SAFETY
PRECAUTIONS
Step
Three
About
This
Manual:
PLEASE
READ
THE
ENTIRE
MANUAL
PRIOR
TO
INSTALLING
OR
USING
THIS
PRODUCT.
This
manual
includes
information
on
three
different
models
of
Remote
Relay
Flow
Controllers
from
FLOWLINE:
LC80
and
LC82
series.
Many
aspects
of
installation
and
use
are
similar
between
the
three
models.
Where
they
differ,
the
manual
will
note
it.
Please
refer
to
the
part
number
on
the
controller
you
have
purchased
as
you
read.
User’s
Responsibility
for
Safety:
FLOWLINE
manufactures
several
models
of
controller,
with
different
mounting
and
switching
configurations.
It
is
the
user’s
responsibility
to
select
a
controller
model
that
is
appropriate
for
the
application,
install
it
properly,
perform
tests
of
the
installed
system,
and
maintain
all
components.
Electrical
Shock
Hazard:
It
is
possible
to
contact
components
on
the
controller
that
carry
high
voltage,
causing
serious
injury
or
death.
All
power
to
the
controller
and
the
relay
circuit(s)
it
controls
should
be
turned
OFF
prior
to
working
on
the
controller.
If
it
is
necessary
to
make
adjustments
during
powered
operation,
use
extreme
caution
and
use
only
insulated
tools.
Making
adjustments
to
powered
controllers
is
not
recommended.
Wiring
should
be
performed
by
qualified
personnel
in
accordance
with
all
applicable
national,
state
and
local
electrical
codes.
Flammable
or
Explosive
Applications
:
The
entire
LC80
series
remote
mount
controllers
should
not
be
used
with
explosive
or
flammable
liquids,
which
require
an
intrinsically
safe
or
explosion
proof.
If
you
are
unsure
of
the
suitability
of
a
controller
for
your
installation,
consult
your
Flowline
representative
for
further
information.
Install
In
a
Dry
Location:
The
controller
housing
is
not
designed
to
be
immersed.
When
installed
properly,
it
should
be
mounted
in
such
a
way
that
it
does
not
normally
come
into
contact
with
liquid.
Refer
to
an
industry
reference
to
ensure
that
compounds
that
may
splash
onto
the
controller
housing
will
not
damage
it.
Such
damage
is
not
covered
by
the
warranty.
Relay
Contact
Rating:
The
relay
is
rated
for
a
10
amp
resistive
load.
Many
loads
(such
as
a
motor
during
start
‐
up
or
incandescent
lights)
are
reactive
and
may
have
an
inrush
current
characteristic
that
may
be
10
to
20
times
their
steady
‐
state
load
rating.
The
use
of
a
contact
protection
circuit
may
be
necessary
for
your
installation
if
the
10
amp
rating
does
not
provide
an
ample
margin
for
such
inrush
currents.
Components:
Part
Number
VAC
Configuration
CSA
Approval
Inputs
Output
LC80
‐
1001
120
Yes
Single
Single
Relay
LC80
‐
1001
‐
E
240
LC82
‐
1001
120
Dual
Dual
Relay
LC82
‐
1001
‐
E
240
Owner’s
Manual