Safety Precautions

 

Step Three 

  

 

 

About Manual: 

PLEASE READ THE ENTIRE MANUAL PRIOR TO INSTALLING OR USING THIS 

PRODUCT. This manual includes information on the mini-float level switch, model LV10-_2_1 and LH25-
_201. Please refer to the part number located on the sensor label to verify the exact model which you have 
purchased.  

 

User’s Responsibility for Safety: 

Flowline manufactures a wide range of liquid level switches and 

technologies.  While each of the these switches are designed to operate in a wide variety of applications, it 
is the user’s responsibility to select a switch model that is appropriate for the application, install it properly, 
perform tests of the installed system, and maintain all components. The failure to do so could result in 
property damage or serious injury.

 

 

Proper Installation and Handling: 

Because this is an electrically operated device, only properly trained 

staff should install and/or repair this product. Use a proper sealant with all installations. Never over tighten 
the sensor within the fitting, beyond a maximum of 80 inch-pounds torque. Always check for leaks prior to 
system start-up. 

 

Material Compatibility: 

The LV20 and LH25 series mini-float level switches are available in two wetted 

material versions.  The LV20-12_1 mini-float vertical switch is made of Polypropylene (PP) with a 
Polyvinylchloride (PVC) cable and the LH25-1201 mini-float horizontal switch is made of Polypropylene 
(PP) with a Polymeric cable.  The LV20-52_1 mini-float vertical switch and the LH25-5201 mini-float 
horizontal switch are made of Polyvinylidene Fluoride (PVDF) with a Tetrafluoroethylene (TFE) cable.  
Make sure that the switch application is compatible with the liquids.  To determine the chemical 
compatibility between the sensor and its application liquids, refer to the Compass Corrosion Guide, 
available from Compass Publications. 

 

Temperature and Pressure:

 The LV20 series switch is designed for use in application temperatures up to 

80˚C, and for use at pressures up to 10 psi (0.7bar).  The LH25 series switch is designed for use in 
application temperatures up to 105˚C, and for use at pressures up to 100 psi (6.9bar). 

 

Wiring and Electrical: 

 The supply voltage used for the LV20 switch should never exceed 240 volts AC @ 

50 VA for the LV20-_2_1.  For the LH25 series, the supply voltage should never exceed 240 Volts AC @ 
30VA. Electrical wiring of the switch should be performed in accordance with all applicable national, state, 
and local electrical codes. 

 

Flammable, Explosive and Hazardous Applications: 

The LV20 and LH25 series mini-float level 

switches should not be used within flammable or explosive applications unless properly connected to an 
approved control device. In hazardous applications, use redundant measurement and control points, each 
having a different sensing technology. Refer to the National Electrical Code (NEC) for all applicable 
installation requirements in hazardous locations. 

Warning

 

Avoid installing the mini-float level switches in magnetized metal tanks.  Doing so will activate the internal reed 
switch. 

 

 

 
 

 

Содержание Switch-Tek LH-25 Series

Страница 1: ...0500 Hu Swit Mini Float Li LV20 LH umbolt Street Los tch T quid Level Sw 25 Series LV Alamitos CA 9072 Tek witch Manual V20 1201 20 p 562 598 3015 5 f 562 431 8507 w flowline com LH25 120 LV20 5201 01...

Страница 2: ...e probe becomes immersed in liquid the float becomes buoyant and the magnet elevates causing the reed switch to change state TABLE OF CONTENTS Specifications 3 Dimensions 4 Safety Precautions 5 Instal...

Страница 3: ...NEMA 6 IP68 Sensor Material LV20 12_1 PP LV20 52_1 PVDF LH25 1201 PP LH25 5201 PVDF Wire Jacket Mat l LV20 12_1 PVC LV20 52_1 TFE LH25 1201 Polymeric LH25 5201 TFE Wire Type 2 conductor 22 gauge Wire...

Страница 4: ...4 MN301310 Rev A Specifications Dimensions Step Two DIMENSIONS LV20 1201 LV20 1251 LV20 5201 LV20 5251 LH25 1201 LH25 5201...

Страница 5: ...lypropylene PP with a Polymeric cable The LV20 52_1 mini float vertical switch and the LH25 5201 mini float horizontal switch are made of Polyvinylidene Fluoride PVDF with a Tetrafluoroethylene TFE ca...

Страница 6: ...or closed for horizontal switches can be changed from normally open when dry to normally closed when dry or vice versa by rotating the float 180 across its axis see Step five Top Wall Installation LV...

Страница 7: ...eries For proper orientation make sure the LV20 series is not off axis more than 20 For the LH25 series make sure the body of the float is horizontal and not off axis by more than 20 In addition make...

Страница 8: ...the factory in the Normally Open NO configuration The normal state is when the float is resting on the bottom of the stem An orientation mark will appear on the top of the float when it is in the NO c...

Страница 9: ...he switch becomes wet the float becomes buoyant and circuit closes As the switch becomes wet the float becomes buoyant and circuit opens CONTACT PROTECTION REED SWITCH When current is interrupted the...

Страница 10: ...Controller LC42 1001 Shown LC10 LC11 Series Controller LC11 1001 Shown NOTE When using a latching relay the polarity of both switches must be equivalent i e both switches are wither wired Normally Ope...

Страница 11: ...ncompatible solvents that may damage the sensor s PP or PVDF plastic body Take particular care to remove any scaling from the float body and make sure that it moves freely 4 Sensor installation Follow...

Страница 12: ...edures outlined above 2 have been subjected to electrical mechanical or chemical damage due to improper accidental or negligent use 3 have been modified or altered 4 anyone other than service personne...

Отзывы: