FlowLine EchoPod DL10 Series Скачать руководство пользователя страница 2

|

   2

 

QS204210 Rev C

 

MN300610 Rev B_9 

2 of 12

 

WELCOME TO THE ECHOPOD

®

 DL10, DL14, DL24, DS14 & DX10 SERIES QUICK START 

The EchoPod

®

 Quick Start provides basic setup and mounting instructions for getting EchoPod

®

 up and 

running quickly. If you have a non-standard installation or setup requirement that is not addressed here, 
please refer to the EchoPod

®

 Manual or support documentation at flowline.com. 

WE DO YOUR LEVEL BEST™ 

Thank you for purchasing EchoPod

®

. Depending upon the series, the general purpose ultrasonic level sensor 

provides non-contact level measurement, switching and/or control. This Quick Start includes everything you’ll 
need to get the sensor up and running.   

COMPONENTS 

EchoPod

®

 comes with a Viton

®

 gasket for installation and the Quick Start.  Some models have the USB

®

 Fob 

(LI99-1001) included with EchoPod

®

 and other’s do not. Fob’s can be purchased separately.  A Fob is 

required to interface to the WebCal

®

 configuration software.  

 

 

  

 
Viton

®

 gasket (1”) 

P/N: 200128 or  
 

 

 
Viton

®

 gasket (1”) 

P/N: 204038 
 

 

 
USB

®

 Key Fob 

P/N: LI99-1001 

 
EchoPod

®

 

DL24 Series 

 

 

 

 

 

EchoPod

®

 

DL10 Series 

EchoPod

®

 

DS14 Series 

EchoPod

®

 

DS14 Series 

EchoPod

®

 

DX10 Series 

 

Содержание EchoPod DL10 Series

Страница 1: ...Alamitos CA 90720 p 562 598 3015 f 562 431 8507 w flowline com QS204210 Rev C DL14 00 Shown 2016 Flowline Inc All Rights Reserved Made in USA DL10 DL14 DL24 DS14 DX10 Series Quick Start EchoPod Ultrasonic Level Switch Controller Transmitter ...

Страница 2: ...series the general purpose ultrasonic level sensor provides non contact level measurement switching and or control This Quick Start includes everything you ll need to get the sensor up and running COMPONENTS EchoPod comes with a Viton gasket for installation and the Quick Start Some models have the USB Fob LI99 1001 included with EchoPod and other s do not Fob s can be purchased separately A Fob i...

Страница 3: ...t all external power is disconnected from EchoPod The maximum distance between the computer and EchoPod is 15 1 Connect the Red Green white and Black wires from the EchoPod to the corresponding colored terminals on the Fob 2 Tighten the terminal screws with a slotted screwdriver 3 Plug the Fob into your PC s USB port Note Wiring is identical for all EchoPod series Only use the Red Black Green and ...

Страница 4: ...e tank 3 Tank Level Configuration a Defines the relay activation and output operational set points 4 Write to Unit a Uploads the configuration into the sensor b Prints a custom PDF wiring schematic c Saves the configuration file for future use Output Configuration Configures the relays in terms of pump valve operations and level alarms as well as the setting fail safe for relays and signal output ...

Страница 5: ...his section is only used when changing the sensor configuration units from the factory default of distance liquid height in inch cm feet or meter to volume liquid in gallons or liters If you wish to configure in distance skip this section If you wish to configure in volume click the Volumetric Mode button select the tank shape units and input the required dimensional information ...

Страница 6: ...v C M Tank Level Configuration Enter the settings for the relay activation points and operational range Complete the Configuration Use the buttons on the right side of the WebCal screen to complete the configuration ...

Страница 7: ... file to assist you in making adjustments or if you are unclear about a specific issue please contact a Flowline applications engineer at 562 598 3015 Increase Output Filtering Placing a check mark in the box will add more output filtering to the 4 20 mA output Decrease Output Filtering Placing a check mark in the box will remove all output filtering from the 4 20 mA output Stabilize Output in Dea...

Страница 8: ...ed Installation in Plastic Tanks Use the LM52 1890 1 bulkhead fitting or a larger bulkhead fitting such as the LM52 2890 with a reducer bushing such as the LM52 1400 or weld a plastic 1 half coupling to the tank top Installation in Metal Tanks Use the LM52 1890 bulkhead fitting or a flange with a 1 riser such as the LM52 1850 where the threads are above the plane of the flange or a larger flange a...

Страница 9: ...n heavy vapor When mounting the sensor in a stand pipe the minimum diameter of the pipe is 2 Larger diameter pipes can be used The pipe should be attached with a coupling and reducer bushing The pipe length should run the measurement span and the bottom of the pipe should remain submerged at all times to prevent foam from entering the pipe Cut the bottom end of the pipe at 45 and drill a 1 4 press...

Страница 10: ... not be connected during usage in the application These wires should not be connected to WebCal while power is supplied from any source other than the USB Fob The maximum cable distance between the computer and EchoPod is 15 Note Never allow the White or Green wires to touch any power supply Blue Orange Yellow Purple Brown DL14 DL24 DS14 Series only Blue Rly1 Orange Rly2 Yellow Rly3 Purple Rly wir...

Страница 11: ...VAC for DS14 series only power on the sensor relays Always use stepper relays between the sensor and external loads For DC circuits use a catch diode such as 1N4148 shown above Protect the sensor from electrical spikes by isolating the power The sensor must be chemically compatible with the application Design a fail safe system for possible sensor and or power failure Never use the sensor in envir...

Страница 12: ...utlined above 2 have been subjected to electrical mechanical or chemical damage due to improper accidental or negligent use 3 have been modified or altered 4 anyone other than service personnel authorized by Flowline have attempted to repair 5 have been involved in accidents or natural disasters or 6 are damaged during return shipment to Flowline Flowline reserves the right to unilaterally waive t...

Отзывы: