Programmable Function Keys User Menu (
USER
)
The
User
menu allows the user to assign the front panel function keys F1, F2, and F3, and the digital in-
put (a digital input located on the signal input connector) to access some of the menus or to activate cer-
tain functions immediately (e.g. reset max & min, hold relay states, etc.). This allows the meter to be
greatly customized for use in specialized applications.
Function Keys & Digital Input Available Settings
Refer to the following table for descriptions of each available function key or digital input setting.
Display
Description
DISP FN
Set the function key or digital input to
display a value
DISPLAY
Cycle max, min, and PV(s)
DISP PV
Display the PV
PCT PV
Display the PV’s percentage of max (20
mA)
D UNITS
Display the PV’s units
D TAG
Display the PV’s tag
DISPMIN
Display the PV’s minimum
DISPMAX
Display the PV’s maximum
MIN MAX
Display the PV’s minimum and maxi-
mum value
D mA IN
Display the mA input value
D mAOUT
Display the mA output value
MENU FN
Set the function key or digital input to
access a menu
RLYINFO
Go to relay information menu (
INFO
)
MANCTRL
Go to output control menu (
CONTROL
)
TIMR OC1
Open collector 1 timer
TIMR OC2
Open collector 2 timer
TIMER R1
Relay 1 timer
TIMER R2
Relay 2 timer
TIMER.FN
Set the function key or digital input to
start or stop a timer
STRT.ALL
Start all timers
STOP.ALL
Stop all timers
S.STP.ALL
Start or stop all timers
OC1
Start/stop open collector 1 timer
OC2
Start/stop open collector 2 timer
RLY1
Start/stop relay 1 timer
RLY2
Start/stop relay 2 timer
START
Start the selected timer output
STOP
Stop the selected timer output
Display
Description
STR‐STP
Start or stop the selected timer output
ALARM.FN
Set the function key or digital input to
acknowledge an alarm
ACK
Acknowledge all active alarms
SETPOINT
View all output set points
SETPT.OC1
View open collector 1 set points
SETPT.OC2
View open collector 2 set points
SETPT.R1
View relay 1 set points
SETPT.R2
View relay 2 set points
SWATCH.FN
Set the function key or digital input to
activate stopwatch
START
Start the stopwatch
STOP
Pause/Stop the stopwatch
STR‐STP
Start or stop the stopwatch
TARE.FN
Set the function key or digital input to
tare the display value
TARE
Tare the display value
RST TARE
Reset the display value
HOLD FN
Set the function key or digital input to
hold an output
HOLD.OUT
Hold all outputs
HLD.UNHLD
Hold or un-hold all outputs
OC1+2
Hold/un-hold open collector outputs
RLY1+2
Hold/un-hold relay outputs
mAOUT
Hold/un-hold 4-20 mA output
HOLD
Hold selected output
HLD.UNHLD
Hold or un-hold selected output
DISABLE
Disable the function key or digital input
RST FN
Set the function key or digital input to
reset a value
RESET
Reset min, max, or max/min PV value
R MIN.MAX
Reset max and min PV value
USER
USER
F1
USER
F2
USER
F3
USER
DI
USER
HINT
F1
DISP FN
F1
MENU FN
F1
TIMER.FN
F1
ALARM.FN
F1
HOLD FN
F1
RST FN
F1
DISABLE
HINT
OFF
HINT
ON
F1
TARE.FN