8. Loosen the coupling that attaches the pneumatic manifold to the vessel, and then
set the manifold aside.
9. Disconnect the cable from the solenoid mounted on the pinch valve.
10. Position wooden blocking between the floor and the abrasive outlet port to
support the vessel during removal.
CAUTION!
The vessel weighs over 90.7 Kg (200 lb) when full.
© 2016–2017 Flow International Corporation
Page 23 of 31
Содержание Paser CF900
Страница 1: ...PASER CF900 ABRASIVE DELIVERY SYSTEM...