© Flow International Corporation
M-416 | 35
CHAPTER 3
Maintenance & Troubleshooting
My pump does not
produce the pressure
requested from
FlowMaster
(continued).
Insufficient water pressure or volume from
operator supply.
•
Check water source (flow rate and pres-
sure; filtration system)
•
Check hoses and fittings for leaks/kinks
Failed inlet check valve (damaged surfaces,
erosion, debris, etc.).
•
Rebuild per service procedure
•
Replace check valve assembly
Failed outlet check valve (damaged surfaces,
erosion, debris, etc.).
•
Rebuild per service procedure
•
Replace check valve assembly
Failed check valve body (damaged seating
surface, cracked indentations from debris).
Replace check valve body.
Failed UHP seal.
May be an indication of a failed plunger, im-
proper tie rod loading, elevated inlet water
temperature, or lack of cooling water (clogged
cooling ports).
•
Inspect seal carrier and plungers (replace as
necessary)
•
Replace dynamic seal and rod seal
Leaking UHP cylinder.
•
Inspect for cracks
•
Inspect seal carrier and check valve body
contact surfaces for spalling, erosion, or
damage. Replace as necessary.
•
Replace the cylinder
Failed UHP tubing and connections.
•
Check gland for proper torque
•
Check collar position
•
Check tubing or fitting for cracks. Replace
as necessary.
•
Check for deformed cone on tubing (may
indicate over-torque). Replace tubing as
necessary.
Failed on/off valve.
•
Install on/off valve service kit
•
Replace on/off valve body
Clogged inlet water filters.
Replace filters (see section
Changing the filter
elements
).
Mis-installed subplate adapter rod seal.
Re-install rod seal properly.
Loose wiring connection to the air propor-
tional control valve.
Check and tighten connections.
Failed or loose connection on the UHP trans-
mitter.
Failed or improperly calibrated UHP pressure
gauge.
Replace gauge or transmitter (the gauge trans-
mitter cannot be re-calibrated).
Excessive length of tubing between pump and
pressure gauge.
Call Flow Technical Service.
Failed air proportional control valve.
Replace air proportional control valve.
Содержание HYPLEX
Страница 1: ...HYPLEX PRIME PUMP M 416 REV C MAY 2012 ...
Страница 7: ... Flow International Corporation M 416 7 CHAPTER 1 Equipment Description ...
Страница 8: ...8 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Страница 9: ... Flow International Corporation M 416 9 CHAPTER 1 Equipment Description ...
Страница 18: ...Notes 18 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Страница 33: ... Flow International Corporation M 416 33 CHAPTER 3 Maintenance Troubleshooting ...
Страница 40: ...Notes 40 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Страница 42: ...High pressure components 42 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Страница 66: ...Notes 66 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Страница 78: ...Notes 78 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Страница 82: ...Notes 82 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Страница 94: ...Notes 94 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...
Страница 100: ...Notes 100 M 416 Flow International Corporation HYPLEX PRIME PUMP Maintenance Service Manual ...