![Flott TBSM 100 Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/flott/tbsm-100/tbsm-100_operating-instructions-manual_2307725034.webp)
ELECTRICAL CONNECTION/DISCONNECTION & OPERATION
-
FOR SINGLE PHASE.
6.
The connection, disconnection, and grounding is carried out t
hrough the plug,
equipped on the sander.
For the safety reason
D
o not change this plug into any the other type in any situation.
2. For the protection of control device, we recommend the Operator to supply
a fuse with 10A current rating
of fuse,
and the total length between fuse and connection terminal shall not exceed 1.5 m.
3. The
exact power source voltage, frequency, and number of phase
shall be checked according to the
installation diagram and circuit diagram.
Ensure that the power switch is in OFF position before electrical connection and disconnection.
OPERATION.
1. "
START
": Push the button marked with "I".
2. "
STOP
": Push the button marked with "O".
MAINTENANCE:
1. Be sure to disconnect the sander from power source.
2. If the motor is overload, the overload relay will be active. If you want to reset sander, open control enclosure
and then push the reset button of overload relay.