Safety 2

For parts or assistance, call Flotec Customer Service at 800-365-6832

Important Safety Instructions

SAVE THESE INSTRUCTIONS - This manual contains 
important instructions that should be followed during 
installation, operation, and maintenance of the product. 

 This is the safety alert symbol. When you see this 

symbol on your pump or in this manual, look for one of 
the following signal words and be alert to the potential 
for personal injury!

 indicates a hazard which, if not avoided, will 

result in death or serious injury.

 indicates a hazard which, if not avoided, 

could result in death or serious injury.

 indicates a hazard which, if not avoided, 

could result in minor or moderate injury.
NOTICE addresses practices not related to 
personal injury.
Carefully read and follow all safety instructions in this 
manual and on pump .
Keep safety labels in good condition. Replace missing or 
damaged safety labels.
California Proposition 65 Warning

 This product and related accessories contain 

chemicals known to the State of California to cause 
cancer, birth defects or other reproductive harm.
1.  Keep safety labels in good condition. Replace 

missing or damaged safety labels.

2.  Consult installer or licensed plumber for correct 

relief valve. Install system according to local codes. 

3.  Always test water from well for purity before using. 

Check local health department for testing procedure.

4.  Before installing or servicing tank, BE SURE pump 

electric power source is disconnected. Release all 
water pressure before working on tank or system. 
Release air pressure before removing cover flange.

5.  Install a relief valve in pump supply line to tank, as 

close to tank as possible.

6.  BE SURE the pump electrical circuit is properly 

grounded.

7.  Remove bleeder orifices, air volume controls or other 

air charging devices in existing system.

8.  DO NOT USE tank as a surge suppressor.

 Risk of hazardous pressure. To prevent 

possible serious or fatal injury and/or damage to 
equipment, system pressure must be less than 100 pounds 
per square inch (PSI) (689kPa) under any circumstances. 
Failure to follow instruction can result in tank blowup. If 
system discharge pressure can exceed 100 PSI (689kPa), 
install a relief valve capable of passing the full pump 
volume at 100 PSI (689kPa).
Do not allow pump, tank, or piping system to freeze . 
Freezing can severely damage equipment and may lead 
to tank explosion and serious injury . Allowing tank to 
freeze voids tank warranty .

Installation

The tank listed below is pre-charged, or filled with 
air at the factory, to 20 pounds per square inch (PSI) 
(138kPa). When installing tank or if drawdown decreases 
significantly, check as follows:
1.  To check air charge in tank, shut off electric power to 

pump, open faucet near tank, and drain completely.

2.  At air valve, unscrew air valve protective cap and 

check tank air pressure with tire gauge. See Chart 1 
for the correct pressure setting. If needed, adjust the 
tank pressure up or down. To do this, bleed air from 
or add air to tank through valve on top of tank.

3.  Use soap or liquid detergent to check for air leaks 

around air valve. Continuous bubbling indicates 
leak. If necessary, release air pressure and install 
new core in air valve (same as used for automobile 
tubeless tires.)

NOTICE Always set or check tank pre-charge with NO 
WATER in tank and no water pressure in system. If you 
have already pumped water before setting or checking 
the pre-charge pressure, turn the pump off. 
NOTICE Replace and tighten air valve protective cap 
after pressure is adjusted correctly. Failure to replace  
cap may allow loss of air pressure and lead to tank 
waterlogging and diaphragm failure.

Chart I

When Pressure Switch  Setting Is

Adjust Tank Precharge (PSI) To

20-40 PSI (138-276kPa)

18 (124kPa)

30-50 PSI (207-345kPa)

28 (193kPa)

40-60 PSI (276-414kPa)

38 (262kPa)

(The first number on the pressure switch is the 
pump “ON” setting; the second number is the pump 
“OFF” setting.)  
This tank is designed to be supported by the system 
piping either directly above the pump or in a convenient 
location in the piping system as close to the pump 
as possible.
NOTICE Tank capacity is different than drawdown. Tank 
capacity is the actual physical volume of the sheet metal 
that makes up the tank. 

Содержание FP7107

Страница 1: ... 800 365 6832 English Pages 2 4 Installation Fonctionnement Pièces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 800 365 6832 Français Pages 5 7 Instalación Operación Piezas Para mayor información sobre el funcionamiento instalación o mantenimiento de la bomba Llame al 800 365 6832 Español Paginas 8 10 2012 FP528 07 24 12 FP7105 08 FP7107 293 Wright...

Страница 2: ...ounds per square inch PSI 689kPa under any circumstances Failure to follow instruction can result in tank blowup If system discharge pressure can exceed 100 PSI 689kPa install a relief valve capable of passing the full pump volume at 100 PSI 689kPa Do not allow pump tank or piping system to freeze Freezing can severely damage equipment and may lead to tank explosion and serious injury Allowing tan...

Страница 3: ...a pre charged tank no bleeder orifices or Air Volume Control AVC are required When sizing a pre charged tank to replace a standard tank the tanks should have equivalent drawdowns Hazardous voltage and hazardous pressure Can shock burn or kill Disconnect all power to pump and bleed all pressure from system before working on pump tank or piping Model Number Maximum Capacity US Gals L Equivalent to S...

Страница 4: ... store Contact FLOTEC Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pump For warranty purposes return the pump s cord tag and original receipt of purchase to the retail store Dispose of the pump according to local disposal ordinances Exceptions to the Twelve 12 Month L...

Страница 5: ...telles possibles et ou l endommagement du matériel il faut maintenir la pression du système à moins de 689 kilopascals kPa 100 PSI en toutes circonstances Le non respect de cet avertissement peut entraîner l explosion du réservoir Si la pression de refoulement du système peut dépasser 689 kPa 100 PSI installer un clapet de surpression capable d assurer le plein débit de la pompe à 689 kPa 100 PSI ...

Страница 6: ...e volume d air n est requis Pour connaître la dimension d un réservoir préchargé pour remplacer un réservoir standard les réservoirs doivent avoir un soutirage équivalent Risque de tension électrique et de pression dangereuses Pouvant causer des brúlures voire la mort Toujours débrancher le courant alimentant la pompe et dissiper toute la pression du système avant d intervenir sur la pompe le rése...

Страница 7: ...LOTEC Les pompes d eaux d égout qui ont été utilisées puis retirées présentent un risque de contamination En cas de défaillance de la pompe d eaux d égout Porter des gants en caoutchouc pour manipuler la pompe À des fins de garantie retourner l étiquette figurant sur le cordon de la pompe et l original du reçu au détaillant Mettre la pompe au rebut conformément à la réglementation locale Exception...

Страница 8: ...equi po la pre sión del sis te ma debe ser in fe rior a 100 lib pulg 2 689 kPa en todo mo men to La omi sión en el res pe to de es tas ins truc cio nes pue de pro du cir el re ven tón del tan que Si la pre sión de des car ga del sis te ma pue de su pe rar las 100 lib pulg 2 689 kPa ins ta le una vál vu la ca paz de ad mi tir el cau dal ple no de la bom ba a 100 lib pulg 2 689 kPa No per mi ta que ...

Страница 9: ... CVA Cuando determine el tamaño del tanque de precarga para reemplazar un tanque estándar los tanques deberán tener aspiraciones adicionales equivalentes Tensión peligrosa y presión peligrosa Puede provocar choque quemadura o muerte Desconecte toda la corriente hacia la bomba y purgue toda la presión del sistema antes de realizar trabajos en la bomba el tanque o la tubería Información sobre el pro...

Страница 10: ...e haya instalado a su tienda minorista Comuníquese con el Departamento de Atención al Cliente de FLOTEC Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminación Si su bomba cloacal ha fallado Use guantes de caucho cuando manipule la bomba Para los fines de la garantía devuelva la etiqueta del cordón de la bomba y el recibo de compra origi...

Страница 11: ...Para refacciones o asistencia llame a Flotec Servicios al Cliente al 1 800 365 6832 11 Pour les services des pièces ou d assistance appeler le service à la clientèle Flotec en composant le 800 365 6832 ...

Страница 12: ......

Отзывы: