DESCRIPTION

This Submersible Sump Pump is designed for home sumps. Unit is equipped
with a 3-prong grounding-type power cord. Ball bearings on motor shaft never
need lubrication. Automatic reset thermal protection.

SPECIFICATIONS

Power supply required ....................................................................115V, 60 HZ.
Motor duty .........................................................................................continuous*
Liquid Temp. Range .........................................................32°F to 77°F(0°-25°C)
Individual Branch Circuit Required (minimum) ......................................10 Amps
Discharge Adapter: ..........................................................................1-1/4" FNPT

*NOTICE: 

For continuous operation, water depth must be at least 5" (13 cm),

to prevent motor overheating.

NOTICE: 

This unit is not designed for applications involving salt water or brine!

Use with salt water or brine will void warranty.

PERFORMANCE

ELECTRICAL & SWITCH SPECIFICATIONS

GENERAL SAFETY INFORMATION

Electrically powered sump pumps normally give many years of trouble-free
service when correctly installed, maintained, and used. However, unusual cir-
cumstances (interruption of power to the pump, dirt/debris in the sump, flood-
ing that exceeds the pump’s capacity, electrical or mechanical failure in the
pump, etc.) may prevent your pump from functioning normally. To prevent pos-
sible water damage due to flooding, consult your retailer about a secondary AC
sump pump, a DC backup sump pump, and/or a high water alarm. See the
“Troubleshooting Chart” in this manual for information about common sump
pump problems and remedies. For more information, see your retailer or call
Flotec customer service at 1-800-365-6832.
1. Know the pump application, limitations, and potential hazards.
2. Disconnect power before servicing.
3. Release all pressure within system before servicing any component.
4. Drain all water from system before servicing.
5. Secure discharge line before starting pump. An unsecured discharge line

will whip, possibly causing personal injury and/or property damage.

6. Check hoses for weak or worn condition before each use, making certain

that all connections are secure.

7. Periodically inspect sump, pump and system components. Keep free of

debris and foreign objects. Perform routine maintenance as required. 

8. Provide means of pressure relief for pumps whose discharge line can be

shut-off or obstructed.

9. Personal Safety:

a. Wear safety glasses at all times when working with pumps.
b. Keep work area clean, uncluttered and properly lighted – replace

all unused tools and equipment.

c. Keep visitors at a safe distance from work area.
d. Make workshop child-proof – with padlocks, master switches, and

by removing starter keys.

10. When wiring an electrically driven pump, follow all electrical and safety

codes that apply.

11.

This equipment is only for use on 115 volt (single phase) and is
equipped with an approved 3-conductor cord and 3-prong, ground-
ing-type plug.

To reduce risk of electric shock, pull plug before ser-

vicing. This pump has not been investigated

for use in swimming pool areas. Pump is supplied with a ground-
ing conductor and grounding-type attachment plug. Be sure it is 
connected only to a properly grounded grounding-type receptacle.

Where a 2-prong wall receptacle is encountered, it must be replaced
with properly grounded 3-prong receptacle installed in accordance
with codes and ordinances that apply.

12. All wiring should be performed by a qualified electrician.
13. Make certain power source conforms to requirements of your equipment.
14. Protect electrical cord from sharp objects, hot surfaces, oil, and chemicals.

Avoid kinking cord. Replace or repair damaged or worn cords immediately.

15. Do not touch an operating motor. Modern motors are designed to operate

at high temperatures.

16. Do not handle pump or pump motor with wet hands or when standing on

wet or damp surface, or in water.

17. Do not use this pump in a fish pond.

If your basement has water or moisture on
floor, do not walk on wet area until all power
has been turned off. If shut-off box is in
basement, call electric company or hydro
authority to shut-off service to house, or call
your local fire department for instructions.
Remove pump and repair or replace. Failure
to follow this warning can result in fatal
electrical shock. Oil on the pump or in the
sump may indicate motor leakage and elec-
trical shock hazard. Turn off power and
check pump for oil leakage from impeller
area. Replace pump if it leaks.

INSTALLATION

1. Install pump in sump pit with minimum diameter of 14" (356mm). Sump

depth should be 18" (457mm). Construct sump pit of tile, concrete, steel or
plastic. Check local codes for approved materials.

2. Install pump in pit so that switch operating mechanism has maximum pos-

sible clearance.

3. Pump should not be installed on clay, earth or sand surfaces. Clean sump

pit of small stones and gravel which could clog pump. Keep pump inlet
screen clear.

NOTICE: 

Do not use ordinary pipe joint compound on plastic pipe. Pipe

joint compound can attack plastics.

4. Install discharge plumbing. Use rigid plastic pipe and wrap threads with

Teflon tape. Screw pipe into pump hand tight +1 – 1-1/2 turns.

Risk of flooding. If a flexible discharge hose is
used, make sure pump is secured in sump to

prevent movement. Failure to secure pump may allow pump
movement, switch interference and prevent pump from starting 
or stopping.

5. To reduce motor noise and vibrations, a short length of rubber hose (1-7/8"

(47.6mm) I.D., e.g. radiator hose) can be connected into discharge line
near pump using suitable clamps.

6. Install an in-line check valve (Flotec No. FP0026-6D) to prevent flow back-

wards through pump when pump shuts off.

NOTICE: 

Flotec check valves are equipped with air bleed hole to prevent

airlocking pump. If using check valve that is not a Flotec valve, drill 1/8"
(3.2 mm) hole in discharge pipe just above pump body but below check
valve to prevent air locks. 

7. Power Supply: Pump is designed for 115 V., 60 Hz., operation and

requires a minimum 10 amp individual branch circuit. Both pump and
switch are supplied with 3-wire cord sets with grounding-type plugs. Switch
plug is inserted directly into outlet and pump plug inserts into opposite end
of switch plug.

Pump should always be electrically grounded to a
suitable electrical ground such as a grounded

water pipe or a properly grounded metallic raceway, or ground 
wire system. Do not cut off round ground pin.

8. If pump discharge line is exposed to outside sub-freezing atmosphere, por-

tion of line exposed must be installed so any water remaining in pipe will
drain to the outfall by gravity. Failure to do this can cause water trapped in
discharge to freeze which could result in damage to pump.

9. After piping and check valve have been installed, unit is ready for operation.
10. Check operation by filling sump with water and observing pump operation

through one complete cycle.

Failure to make this operational check may lead to
improper operation, premature failure, and 

flooding.

Submersible

Sump Pumps

OPERATION & INSTALLATION INSTRUCTIONS

GPH (LPH) AT TOTAL FEET (M)

Motor

5

10

15

Series

HP

(1.5m)

(3m)

(4.5m)

CAPACITY GALLONS(L)/HOUR

FP0S1700A

3/10

1700

1200

550

17 Ft.

(6 435)

(4 542)

(2 082)

(5.2M)

FP0S2100A

4/10

2100

1700

925

18 Ft.

(7 949)

(6 435)

(3 501)

(5.5M)

For further operating, installation, or maintenance assistance: 

Call 1-800-365-6832

FP470 (Rev. 3/25/03)

No flow 

at height

shown

below

Motor

Individual

*Switch Setting

Motor

Full Load

Branch Circuit

in inches (mm)

Series

HP

Amps

Req. (Amps)

On

Off

FP0S1700A

3/10

2.6

10

11"(279)

5"(127)

FP0S2100A

4/10

3.0

10

11"(279)

5"(127)

®

P.O. Box 342, Delavan, WI 53115

Phone:

1-800-365-6832 • 

Fax:

1-800-526-3757

E-Mail:

[email protected] • 

Web Site:

http://www.flotecpump.com

Risk of electrical shock.

Can burn or kill.

Содержание FP0S1700A Series

Страница 1: ...pump in a fish pond If your basement has water or moisture on floor do not walk on wet area until all power has been turned off If shut off box is in basement call electric company or hydro authority...

Страница 2: ...ABLE EXPRESS WARRANTIES PROVIDED HEREIN Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts so the above li...

Страница 3: ...utiles c Les visiteurs doivent se tenir une distance s curitaire de la zone de travail d Poser des cadenas pour s assurer que les enfants ne pour ront pas p n trer dans l atelier de travail Poser auss...

Страница 4: ...u d eau mis la terre une canalisation m tallique ad quatement mise la terre ou un circuit lectrique ad quatement mis la terre par exemple Ne jamais couper la broche ronde de mise la terre de la fiche...

Страница 5: ...dessous Garantie de quatre 4 ans Si dans les quatre 4 ans compter de la date d achat par le consommateur d origine une pompe d ass chement submersible FLOODMATEMD 7000 ou IRONMATEMD s av rait tre d fe...

Страница 6: ...se use c Mantenga a los visitantes a una distancia segura del lugar de trabajo d Aseg rese de que su taller sea a prueba de ni os con candados interruptores maestros y sacando las llaves del arrancado...

Страница 7: ...st puesta a tierra o un conducto met lico debidamente puesto a tierra o un sistema de alambre de puesta a tierra No corte la clavija redonda de puesta a tierra 8 Si la tuber a de descarga de la bomba...

Страница 8: ...osible Ning n pedido de servicio bajo esta garant a ser aceptado si se recibe m s de 30 d as despu s del t rmino de la garant a Esta garant a establece la obligaci n nica de FLOTEC y el remedio exclus...

Отзывы: