6

Technical Data

FP  7K

VIP 130/6

Mains  voltage  /  frequency

230 V ~ 50 Hz

230 V ~ 50 Hz

Absorbed power

250 Watt

320 Watt

Type of protection / Insulation class

IP X8

IP X8

Suction  fitting

41,90 mm (1"1/4M)

41,90 mm (1"1/4M)

Maximum flow rate

7.800 l/h

7.800 l/h

Maximum head

6 m

6 m

Maximum depth of immersion

7 m

7 m

Power cable

10  m  H05  RNF

10 m H05 RNF

Weight

3,8 Kg

3,9 Kg

Maximum dimension of pumped solid particles

6 mm

6 mm

Maximum temperature of the pumped fluid

35° C

35° C

Maximum number of starts per hour, uniformly distributed

30

30

Minimum priming level (A)*

100 mm

100 mm

Minimum suction level (B)*

  20 mm

  20 mm

Connection level (C)*

330 mm

330 mm

Stop level (D)*

150 mm

150 mm

GB

Ch. 3 Installation (see Fig. 1)

When installing, please ensure electropump is disconnected from
electrical supply. Pumps in this series are not suitable for use in a
swimming pool and the relevant cleaning and servicing operations.

Electric shock
risk

DANGER

To prevent possible injuries to people, avoid inserting hands into the mouth of the
pump if this is connected to the mains.

DANGER

Use the handle provided to transport or lift the pump. To use the pump in permanent installations with rigid pipes, to
install a check valve to avoid the fluid being re-circulated once the pump is stopped. The installation of a quick closing
fitting in a convenient position facilitates cleaning and maintenance operations.

GB

2

Technical Data

VIP 180/7

Mains  voltage  /  frequency

230 V ~ 50 Hz

Absorbed power

370 Watt

Type of protection / Insulation class

IP X8

Suction  fitting

41,90 mm (1"1/4M)

Maximum flow rate

10.800 l/h

Maximum head

7  m

Maximum depth of immersion

7 m

Power cable

10 m H05 RNF

Weight

4,2 Kg

Maximum dimension of pumped solid particles

6 mm

Maximum temperature of the pumped fluid

35° C

Maximum number of starts per hour, uniformly distributed

30

Minimum priming level (A)*

100 mm

Minimum suction level (B)*

  20 mm

Connection level (C)*

330 mm

Stop level (D)*

150 mm

Sound pressure level (Lpa) equal to or less than 70 dB(A)
Sound emission values obtained in conformity with the EN 12639 standard
(*) These data refer to Fig. 1. Measurements are expressed in millimetres.
The minimum priming level corresponds to a condition in which the delivery mouth is completely submersed.
(See Fig. 1 - Reference A)
The pumps of this series are not suitable for table fountains or aquariums. If these pumps are used in continuous mode for
ponds with fish, it is necessary to check them at regular intervals of 6 months (if the water contains aggressive substances).
It is also advisable to check the maximum dimension of particles recommended for the pump and take the necessary
measures to prevent the fish from being sucked into the pump.

DANGER

This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.

Отзывы: