For parts or assistance, call Flotec Customer Service at 

1-800-365-6832

READ AND FOLLOW 

SAFETY INSTRUCTIONS!

This is the safety alert symbol. When you see this sym-

bol on your pump or in this manual, look for one of the fol-

lowing signal words and be alert to the potential for personal
injury!

warns about hazards that will cause serious per-

sonal injury, death or major property damage if ignored.

warns about hazards that can cause serious

personal injury, death or major property damage if ignored.

warns about hazards that will or can cause

minor personal injury or property damage if ignored.
The label NOTICE indicates special instructions which are impor-
tant but not related to hazards.
Make sure installation complies with all electrical / plumbing
codes.

Hazardous Voltage. Can cause serious or

fatal electrical shock. Disconnect power to pump before ser-
vicing.

If floor is wet, disconnect power at main electrical service

before  walking on it. Do not stand in water or touch metal

surfaces when switching circuit breaker or removing/installing
fuses.

Pump is equipped with a three-prong, grounding cord and

plug. Plug into a properly grounded, grounding type recep-

tacle only. Do not modify cord or plug. Plug into a 115V, 15 amp
circuit only.

Do not use in explosive environments. Pump

water only with this pump. Inspect sump, pump and system
components monthly. Keep free of debris and foreign objects.
Perform routine maintenance as required.

Risk of flooding. If a flexible discharge hose

is used, pump may move around in sump when motor
starts. 
If it moves far enough so that switch hits side of sump,
switch may stick and prevent pump from starting. Make sure
pump is secured so it cannot move around in sump.
Electrically powered sump pumps normally give many years of
trouble-free service when correctly installed, maintained, and
used. However, unusual circumstances (interruption of power to
the pump, dirt/debris in the sump, flooding that exceeds the
pump’s capacity, electrical or mechanical failure in the pump,
etc.) may prevent your pump from functioning normally. To pre-
vent possible water damage due to flooding, consult your dealer
about installing a secondary sump pump, a DC backup sump
pump, and/or a high water alarm. See the “Troubleshooting
Chart” in this manual for information about common sump pump
problems and remedies. For more information, see your dealer
or call customer service at 1-800-323-0620.

SPECIFICATIONS

Power Supply Required. ............................................115V, 60HZ.
Motor Duty....................................................................Continuous
Liquid Temperature Range ....................................77°F Maximum
Circuit Requirement (minimum) ....................................15.0 Amps
Motor Full Load (maximum) ............................................7.5 Amps
Discharge (Insert for 1-1/4” also included).......1-1/2" Slip Adapter

PERFORMANCE

OPERATION

Pump is equipped with an automatic float switch which starts
pump when water level reaches 10"-12". Pump automatically
turns off when level drops to 4" - 6". 

GENERAL GUIDELINES 

Sump should be at least 18" deep. Inside diameter of sump
should be at least 14".
Check Valve is built-in. If necessary to allow flowback from dis-
charge pipe to sump:
• Drill 1/8" diameter hole in discharge line above pump.
• Cut 1/2" V notch in check valve lip. If required by local code, a 

separate in-line check valve can be installed without harming
pump.

Discharge Pipe: Pump is supplied with flexible connector that fits
1-1/2” PVC or ABS pipe. Adapter insert allows use of 1-1/4” PVC
or ABS pipe. PVC or ABS adapters may be purchased to fit other
discharge pipe sizes.

ELECTRICAL

Hazardous voltage. Can cause severe or fatal

electrical shock. Pump is supplied with a grounding conductor
and grounding-type attachment plug. To reduce risk of electric
shock, be certain that it is connected only to a properly ground-
ed, grounding type receptacle.
A ground fault circuit is recommended for use with any electrical
appliance submerged in water. For installation of such a circuit,
consult a licensed electrician.

ELECTRICAL SERVICE

AC power outlets should be on a separate 15 amp circuit; 115V,
AC, 60 cycles, and located within 8 ft. of sump. Ground terminal
on pump cord plug is provided for your protection. DO NOT
REMOVE!

PUMP INSTALLATION

1. Remove debris and foreign material etc., from sump to pre-

vent clogging.

2. Place pump on smooth, level surface. Use building blocks or

bricks to elevate pump screen a minimum of  2" above mud,
sand or loose stones.

3. Locate pump in center of pit so pump housing and float con-

trol will not come in contact with side of pit and create opera-
tional problems.

4. Slip connector hose over pump discharge. Install and tighten

first clamp.

5. Place second clamp loosely over connector hose.
6. Slip connector hose over discharge pipe. Clamp hose tightly

with second clamp. Run discharge piping to nearest outlet,
depending on local plumbing codes. Discharge piping should
be as short as possible to reduce pipe friction losses.
Discharge pipe diameter should be equal to or larger than dis-
charge size of pump. Smaller pipe diameters will restrict
capacity of pump and reduce performance.

7. Securely anchor flexible discharge line if used. If line is not

secure, pump may tip during operation.

Total Lift in Feet

5'

10'

15'

20'

25'

Capacity in GPM

100

84

64

39

0

Содержание FLOODMATE 6000

Страница 1: ...i ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Fran ais Pages 4 5 Instalaci n Operaci n Piezas Para mayor informaci n sobre el func...

Страница 2: ...5V 60HZ Motor Duty Continuous Liquid Temperature Range 77 F Maximum Circuit Requirement minimum 15 0 Amps Motor Full Load maximum 7 5 Amps Discharge Insert for 1 1 4 also included 1 1 2 Slip Adapter P...

Страница 3: ...SHOOTING CHART Hazardous Voltage Can cause serious or fatal electrical shock Disconnect power to pump before servicing SYMPTOM PROBABLE CAUSE S CORRECTIVE ACTION Motor does not run Blown fuse Replace...

Страница 4: ...amp res Charge totale sur le moteur maximum 7 5 amp res Refoulement garniture pour 1 1 4 pouce aussi incluse adaptateur coulissant de 1 1 2 pouce RENDEMENT FONCTIONNEMENT La pompe est quip e d un int...

Страница 5: ...nne pas v rifier le service lectrique LISTE DES PI CES DE RECHANGE TABLEAU DE RECHERCHE DES PANNES Tension dangereuse Risque de blessures ou de secousses lectriques mortelles D brancher le courant ava...

Страница 6: ...el l quido 77 grados F m ximo Requisitos del circuito m nimo 15 0 amperios Carga total del motor m ximo 7 5 amperios Descarga tambi n incluye inserci n para 1 1 4 Adaptador de deslizamiento de 1 1 2 R...

Страница 7: ...TA DE LOCALIZACI N DE FALLAS Tensi n peligrosa Puede ocasionar choques el ctricos graves o fatales Desconecte la corriente el ctrica hacia la bomba antes de realizar trabajos de reparaci n o mantenimi...

Страница 8: ...rouille ou autre corps tranger dans le syst me ou des produits ayant fonctionn des pressions d passant la limi te maximale recommand e Les demandes de service en vertu de la pr sente garantie seront f...

Отзывы: