FLOTEC warrants to the original consumer purchaser (“Purchaser”) of its prod-
ucts that they are free from defects in material or workmanship.
If within twelve (12) months from the date of the original consumer purchase
any such product shall prove to be defective, it shall be repaired or replaced
at FLOTEC’s option, subject to the terms and conditions set forth below. Your
original receipt of purchase is required to determine warranty eligibility.
Exceptions to the Twelve (12) Month Warranty
Ninety (90) Day Warranty:
If within ninety (90) days from original consumer purchase any Drill Pump,
Pitcher Pump, or In-Line Water Filter Cartridge shall prove to be defective, it
shall be replaced, subject to the terms set forth below.
Two (2) Year Warranty:
If within two (2) years from original consumer purchase any 1/3 HP
Submersible Sump Pump or Model FP2800DCC shall prove to be defective, it
shall be repaired or replaced at FLOTEC’s option, subject to the terms and con-
ditions set forth below.
Three (3) Year Warranty:
If within three (3) years from original consumer purchase any 4” Submersible
Well Pump, or 1/2 HP Submersible Sump Pump, shall prove to be defective, it
shall be repaired or replaced at FLOTEC’s option, subject to the terms and con-
ditions set forth below.
Four (4) Year Warranty:
If within four (4) years from original consumer purchase any FLOODMATE

TM

7000 or IRONMATE

TM

Submersible Sump Pump shall prove to be defective, it

shall be repaired or replaced at FLOTEC’s option, subject to the terms and
conditions set forth below.
Five (5) Year Warranty:
If within five (5) years from original consumer purchase any Pre-Charge water
system tank shall prove to be defective, it shall be repaired or replaced at
FLOTEC’s option, subject to the terms and conditions set forth below.

General Terms and Conditions
Purchaser must pay all labor and shipping charges necessary to replace prod-
uct covered by this warranty. This warranty shall not apply to acts of God, nor
shall it apply to products which, in the sole judgement of FLOTEC, have been
subject to negligence, abuse, accident, misapplication, tampering, alteration;
nor due to improper installation, operation, maintenance or storage; nor to
other than normal application, use or service, including but not limited to,
operational failures caused by corrosion, rust or other foreign materials in the
system, or operation at pressures in excess of recommended maximums.
Requests for service under this warranty shall be made by returning the defec-
tive product to the Retail outlet or to FLOTEC as soon as possible after the dis-
covery of any alleged defect. FLOTEC will subsequently take corrective action
as promptly as reasonably possible. No requests for service under this warran-
ty will be accepted if received more than 30 days after the term of the war-
ranty.
This warranty sets forth FLOTEC’s sole obligation and purchaser’s exclusive
remedy for defective products.
FLOTEC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL,
OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL
OTHER EXPRESS WARRANTIES. IMPLIED WARRANTIES, INCLUDING BUT
NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE
DURATION OF THE APPLICABLE EXPRESS WARRANTIES PROVIDED HERE-
IN.
Some states do not allow the exclusion or limitation of incidental or conse-
quential damages or limitations on how long an implied warranty lasts, so the
above limitations or exclusions may not apply to you. This warranty gives you
specific legal rights and you may also have other rights which vary from state
to state.

Flotec Limited Warranty

FLOTEC • P.O. Box 342 • Delavan, WI U.S.A. 53115

Phone: 1-262-728-5551 • Fax: 1-262-728-4461

E-Mail: [email protected] • Web Site: http://www.flotecwater.com

Safety

2

READ AND FOLLOW 

SAFETY INSTRUCTIONS!

This is the safety alert symbol. When you see this

symbol on your pump or in this manual, look for

one of the following signal words and be alert to the
potential for personal injury:

warns about hazards that will cause serious

personal injury, death or major property damage if
ignored.

warns about hazards that can cause serious

personal injury, death or major property damage if
ignored.

warns about hazards that will or can cause

minor personal injury or property damage if ignored.

The label NOTICE indicates special instructions which
are important but not related to hazards.

Carefully read and follow all safety instructions in this
manual and on pump.

Keep safety labels in good condition. 
Replace missing or damaged safety labels.

1. Read this manual carefully. Failure to follow these

Instructions could cause serious bodily injury and/or
property damage.

2. Check your local codes before installing. You must

comply with their rules. 

3. Vent sewage or septic tank according to local codes.

4. Do not install pump in any location classified as 

hazardous by National Electrical Code, ANSI/NFPA
70-1990.

Hazardous voltage, Can shock, burn or

cause death. During operation, the pump is in water. To
avoid fatal shocks, proceed as follows if pump needs ser-
vicing:

Risk of electrical shock. Can burn or kill.

Do not lift pump by power cord. See “Cord Lift
Warning” on Page 6.

5A. Disconnect power to outlet box before unplugging

pump.

5B. Take extreme care when changing fuses. Do not

stand in water or put your finger in fuse socket.

5C. Do not modify cord and plug. When using cord and

plug, plug into a grounded outlet only. When wiring
to a system control, connect pump ground lead to
system ground.

6. Do not run pump dry. Dry running can overheat

pump, (causing burns to anyone handling it) and will
void warranty. 

7. Pump normally runs hot. To avoid burns when ser-

vicing pump, allow it to cool for 20 minutes after
shut-down before handling it.

8. In normal service, motor should not need oiling.

Motor has been filled at the factory with a special
oil.

ATTACH ORIGINAL RECEIPT HERE FOR WARRANTY CONSIDERATION.

Содержание 4202A Series

Страница 1: ... Installation Fonctionnement Pièces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 262 728 5551 Français Pages 8 13 Instalación Operación Piezas Para mayor información sobre el funcionamiento instalación o mantenimiento de la bomba Llame al 1 262 728 5551 Español Paginas 14 19 P O Box 342 Delavan WI 53115 Phone 1 800 365 6832 Fax 1 800 526 3757 E M...

Страница 2: ... s exclusive remedy for defective products FLOTEC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL INCIDENTAL OR CONTINGENT DAMAGES WHATSOEVER THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL NOT EXTEND BEYOND THE DURATION OF THE APPLICABLE...

Страница 3: ...fety instructions listed below Step 1 DO NOT splice the electrical power cord Step 2 DO NOT allow electrical cord plug to be submerged Step 3 DO NOT use extension cords They are a fire hazard and can reduce voltage sufficiently to prevent pumping and or damage motor Step 4 DO NOT handle or service pump while it is connected to power supply Connect or wire pump to its own circuit with no other outl...

Страница 4: ...ump and control switch After removing basin cover and necessary discharge piping lift pump out of basin Risk of electrical shock Can burn or kill Do not lift pump by power cord See Cord Lift Warning Place pump in an area where it can be cleaned thoroughly Remove all scale and deposits on pump Submerge pump in disinfectant chlorox or chlorine for at least one hour before dis assembling pump The pum...

Страница 5: ...ide edge of seal body with spring Key No 9A Step 1 Press new seal body and spring Key No 9A into cavity in seal plate NOTICE Coat rubber bellows with soap or oil to aid in installing seal on shaft Step 2 Reverse steps 7 through 9 to reassemble motor and shaft NOTICE Do not overtighten through bolts Step 3 Slide new rotating ceramic member of seal Key No 9B onto shaft Step 4 Reassemble impeller was...

Страница 6: ...or 30 minutes to allow motor to cool then reconnect to power source Check for cause of overheating overloading 1 Be sure all valves in discharge valve are fully open 2 Clean out discharge pipe and check valve 3 Check for blockage in pump inlet or impeller 4 Pump not sized properly A higher capacity pump may be required 1 Check switch or controller automatic floats for proper operation and location...

Страница 7: ... 1 PW18 54C 6 1 4 20x1 1 2 Hex Hd Screw 4 U30 883SS 7 Seal Plate 1 PW18 53A 8 Volute 1 PW1 3AW 9 Shaft Seal Incl 9A and 9B 1 U109 321SS 9A Stationary Seal Half w Spring 1 U9 379A 9B Rotating Seal Half 1 U9 321A 10 Impeller 1 PW5 3 11 Hex Jam Nut 7 16 20 1 U36 33SS 12 Spring Washer 1 U43 112SS 13 O Ring 1 U9 365 14 1 4 20x1 Soc Hd Screw 4 U30 475SS 15 Power Cord 1 PW17 240 Cord Clamp 1 CC0030 13 Cl...