background image

 

 FLORIDA-PNEUMATIC.COM 

 

Please contact 1-800-356-3392 for further assistance.

Operation

Operating the angle die grinder

 

This Angle Die Grinder is designed to operate on 90 PSIG. 
Lower pressure (below 90 PSIG) will reduce performance 
of the tool. Higher air pressure (over 90 PSIG) raises the 
performance of the tool beyond its rated capacity and 
could cause serious damage to the tool and the user. 
 

Installing the grinding stone 

 

WARNING:

 Disconnect the tool from the air supply before 

servicing or changing accessories.

WARNING:

  Always use ANSI approved grinding stones 

with the rated tool RPM.

Removing the grinding stone 

 

 

WARNING:

 Disconnect the tool from the air supply before 

servicing or changing accessories.

 

Loosen the collet nut with the spanner wrenches. 

 

Pull the grinding stone out and tighten the collet nut with the 
spanner wrenches.

Grinding and deburring 

 

WARNING:

 You must wear the ANSI approved eye 

protection during the operation; failure to follow this this may 
result in serious injury or damage to the operator.

WARNING:

 Hearing protection is strongly recommended. A 

protective respirator is recommended.

 

Connect the die grinder to the air supply.  

 

This tool features the safety lock-off mechanism.

 

Operate the tool by disengaging the lock-off mechanism 
and depressing the throttle lever to run the tool for 
grinding or deburring. 

 

Loosen the collet nut with the spanner wrenches.

 

Insert the grinding stone in the collet. If using a 1/8 in. collet 
stone, an adapter (not included) must be inserted before 
placing the stone into the tool.

 

Tighten the collet nut with the spanner wrenches.

Содержание UT8749ADG-1

Страница 1: ...eneral Safety Information 2 Air Compressor and Air Tool Safety 2 3 Tool Specifications 3 Installation 4 Maintenance Lubrication 4 Operation 5 Troubleshooting 6 Warranty 6 Service Parts 7 UT8749ADG 1 A...

Страница 2: ...used in a dust filled environment exhaust air can cause a dust hazard Dusts and fumes generated when using power tools can cause ill health for example cancer birth defects asthma and or der matitis r...

Страница 3: ...t are specifically designed to filter out microscopic particles Important Warnings Die Grinders Specifications 1 Only use mounted grinding stones or mounted carbide burrs that meet ANSI standards ISO...

Страница 4: ...arly check and fill the in line lubricator with air tool oil Avoid using excessive amounts of oil Adjust the in line lubricator by placing a sheet of paper next to the tool s exhaust ports and holding...

Страница 5: ...ing accessories Loosen the collet nut with the spanner wrenches Pull the grinding stone out and tighten the collet nut with the spanner wrenches 4 Grinding and deburring WARNING You must wear the ANSI...

Страница 6: ...rease There is moisture blowing out of the tool s exhaust There is water in the tank Drain the tank See the air compressor manual for instructions Lubricate the tool and run it until water is not evid...

Страница 7: ...FLORIDA PNEUMATIC COM Please contact 1 800 356 3392 for further assistance Service Parts Exploded View Drawing...

Страница 8: ...matic Manufacturing Corporation 851 Jupiter Park Lane Jupiter FL 33458 Universal Tool Questions problems missing parts Call Customer Service 8 a m 5 p m EST Monday Friday 1 800 356 3392 FLORIDA PNEUMA...

Отзывы: