background image

 

 FLORIDA-PNEUMATIC.COM 

 

Please contact 1-800-356-3392 for further assistance.

Operation

Operating the angle die grinder

 

This Angle Die Grinder is designed to operate on 90 PSIG. 
Lower pressure (below 90 PSIG) will reduce performance 
of the tool. Higher air pressure (over 90 PSIG) raises the 
performance of the tool beyond its rated capacity and 
could cause serious damage to the tool and the user. 
 
  
 
 
 

Installing the grinding stone 

 

WARNING:

 Disconnect the tool from the air supply before 

servicing or changing accessories.

WARNING:

  Always use ANSI approved grinding stones 

with the rated tool RPM.

Removing the grinding stone 

 

 

WARNING:

 Disconnect the tool from the air supply before 

servicing or changing accessories.

 

Loosen the collet nut with the 17 MM wrench and the 11 MM 
wrench. 

 

Pull the grinding stone out and tighten the collec nut with the 
17 MM wrench and the 11 MM wrench.

Grinding and deburring 

 

WARNING:

 You must wear the ANSI approved eye 

protection during the operation; failure to follow this this may 
result in serious injury or damage to the operator.

WARNING:

 Hearing protection is strongly recommended. A 

[rotective respirator is recommended.

WARNING:

 Always use the sanding pad with the rated tool 

RPM.

 

 

Loosen the collet nut with the 17 MM wrench and the 11 MM 
wrench.

 

Insert the grinding stone in the collet. If using a 1/8 in. collet 
stone, an adapter (not included) must be inserted before placing 
the stone into the tool.

 

Tighten the collet nut with the 17 MM wrench and the 11 MM 
wrench.

 

Connect the die grinder to the air 
supply.  

 

This tool features the safety lock-
off mechanism.

 

Operate the tool by disengaging 
the lock-off mechanism and 
depressing the throttle lever to run 
the tool for grinding or deburring.

Tighten

Loosen

Содержание Universal Tool RAPTOR UT8727-12

Страница 1: ...eral Safety Information 2 Air Compressor and Air Tool Safety 2 3 Tool Specifications 3 Installation 4 Maintenance Lubrication 4 Operation 5 Troubleshooting 6 Warranty 6 Service Parts 7 UT8727 12 RAPTO...

Страница 2: ...used in a dust filled environment exhaust air can cause a dust hazard Dusts and fumes generated when using power tools can cause ill health for example cancer birth defects asthma and or der matitis r...

Страница 3: ...ks that are specifically designed to filter out microscopic particles Important Warnings Die Grinders Specifications 1 Only use mounted grinding stones or mounted carbide burrs that meet ANSI standard...

Страница 4: ...ained operation Regularly check and fill the in line lubricator with air tool oil Avoid using excessive amounts of oil Adjust the in line lubricator by placing a sheet of paper next to the tool s exha...

Страница 5: ...MM wrench Pull the grinding stone out and tighten the collec nut with the 17 MM wrench and the 11 MM wrench 4 Grinding and deburring WARNING You must wear the ANSI approved eye protection during the...

Страница 6: ...rease There is moisture blowing out of the tool s exhaust There is water in the tank Drain the tank See the air compressor manual for instructions Lubricate the tool and run it until water is not evid...

Страница 7: ...ase contact 1 800 356 3392 for further assistance Service Parts Exploded View Drawing 28 19 22 11 10 9 6 5 1 12 13 14 15 24 42 43 41 40 39 38 37 36 35 34 33 32 31 30 29 8 27 26 25 44 45 37 46 48 49 47...

Страница 8: ...matic Manufacturing Corporation 851 Jupiter Park Lane Jupiter FL 33458 Universal Tool Questions problems missing parts Call Customer Service 8 a m 5 p m EST Monday Friday 1 800 356 3392 FLORIDA PNEUMA...