13
IE
GB
NI
Trouble Shooting
Problem
Possible cause
Fault correction
Device does not start
Mains voltage not on
Check plug socket, cable, line and
plug, where appropriate, have re-
paired through electrical specialist
On/Off switch (
6) or
deadman switch (
4)
defective
Repair by Service Centre
Worn carbon brushes
Defective motor
Device runs with inter-
ruptions
Power cable is damaged
Check the cable and have it
changed by the Service Centre if
necessary
Internal loose electrical
connection
Repair by Service Centre
On/Off switch (
6) or
deadman switch (
4)
defective
Blades become hot
Blades (
2) are blunt
Have the blades sharpened or
replaced (Service Centre)
Blades (
2) are notched Have the blades checked or re-
placed (Service Centre)
Too much friction due to
lack of lubrication
Oil the blades (
2)