7
5.
Operating
When operating the floor grinding machine, the following safety measures have to
be followed.
Only use earthed electrical cables with a diameter of at least 2,5mm2.
Ensure, when operating the machine, no unnecessary things are placed on the
machine. NEVER stop the sawing-blade by placing pressure on the side of the
blade.
Only use original sawing-blades of Flooriq.
Removing the sawing-blade
ALWAYS remove the plug from the socked before changing the sawing-blade. Also,
wear a dust mask of class P3. Furthermore, make sure the sawing-blade is
completely out of the floor.
1
Remove the plastic nut of the dust hood and remove the hood.
2
Remove the plastic nut from the electronic depth shaft
(warning: prevent the engine from moving) and carefully tilt
the engine forward.
3
Turn the 6-sided nut from the shaft with the appropriate wrench.
4
Remove the sawing-blade.
Mounting the sawing-blade
Mounting the sawing-blade happens in reversed order.
1
Place the new sawing-blade over the shaft.
2
Turn the 6-sided nut tightly around the shaft with the
appropriate wrench.
3
Carefully tilt the engine forward and place the plastic nut onto
the electronic depth shaft.
4
Place the dust hood pack onto the machine and secure it with
the plastic nut.
Adjust the sawing depth
1
Turn the switch to “in” to lower the sawing-blade into the floor
and release the switch when reaching the preferred depth.
2
Turn the switch to “out” to remove the sawing-blade from the
floor.
Warning: Always turn on the vacuum before lowering the sawing-blade into the
floor.