Flomec TM Series Скачать руководство пользователя страница 10

OPERA

TION

 /

CALIBRA

TION

ASSEMBL

Y /

 

INST

ALLA

TION

SAFETY

 / 

SPECIFICA

TIONS

GETTING

 ST

ARTED

10

PARTS & SERVICE

For warranty consideration, parts, or other service information, please 

contact your local distributor. If you need further assistance, contact  

the GPI Product Support Department in Wichita, Kansas, during  

normal business hours.
A toll free number is provided for your convenience.

1-888-996-3837

To obtain prompt, efficient service, always be prepared with the following 

information:
• 

The model number of your meter.

• 

The serial number or manufacturing date code of your meter.

• 

Part descriptions and numbers.

For warranty work, always be prepared with your original sales slip or other 

evidence of purchase date.

PARTS / ACCESSORIES LIST FOR TM SERIES METERS

 

Part Number

 

Description

116000-1

Calibration container, Large (5 gallon)

901002-52

Seal

113435-10

Conditioned Signal Module (GEN 2)

125060-10

Pulse Access/External Power/Scaled Module (GEN 2)

125100-10

4-20mA Module

IMPORTANT:

 Please contact GPI before returning any parts. It may be 

possible to diagnose the trouble and identify needed parts in a telephone 
call.

This product is in compliance with the RoHS 
Directive of the European Parliament and of the 
Council on the Restriction of the Use of Certain 
Hazardous Substances in Electrical and Electronic 
Equipment. 

Environmental Rating: IP65

MAINTENANCE

 / 

REP

AIR

Do not return this product without prior approval from the GPI Product 

Support Department. Due to strict government regulations, GPI cannot 

accept parts unless they have been drained and cleaned.

WEEE DIRECTIVE

ROHS COMPLIANT (2011/65/EU)

Содержание TM Series

Страница 1: ...TM Series Electronic Water Flowmeters Product Owner s Manual EN 920786 02 Rev D 07 16 2020 1 2 INCH 2 INCH METER SIZES TM05XXXXXX TM20XXXXXX MODELS ...

Страница 2: ...r to back cover for information regarding this product s warranty and other important information SAVE FOR YOUR RECORDS Model ____________________ Serial ____________________ Purch Date ________________ DO NOT RETURN THIS PRODUCT TO THE STORE Please contact Great Plains Industries Inc before returning any product If you are missing parts or experience problems with your installation contact our Cu...

Страница 3: ... filed with carrier See General Safety Instructions and all Cautions Warnings and Dangers as shown tools eps box eps magnify_2 eps warning symbol eps measure eps plug eps oil eps megaphone eps biohaz eps Battery_Caution1 eps Caution eps Crush_Caution1 eps Heavy_Hazard eps Hot_surface eps Recycle eps Resp_protection1 eps Resp_protection2 eps Temp_Caution1 eps body_protection eps chemical_Caution ep...

Страница 4: ...ations for temperature or pressure See specifications for your model Make sure flow and pressure have been eliminated from process pipe prior to installing or removing product Always use appropriate thread sealant or flange gaskets when connecting product to process piping To protect against leakage seal all pipe threads with an appropriate sealing compound Make sure the sealing compound does not ...

Страница 5: ...eze inside meter Storage Temperature 40 F to 140 F 40 C to 60 C Field Calibration Yes Wetted Components Housing PVC Journal bearings Ceramic Shaft Tungsten carbide Rotor and supports PVDF Retaining washer Stainless steel Inlet Outlet Connections TM05 TM07 TM10 TM15 TM20 S SPIGOT 1 2inchSchd 80 3 4inchSchd 80 1inchSchd 80 1 1 2inch Schd 80 2inchSchd 80 N NPT 1 2 inch NPT 3 4 inch NPT 1 inch NPT 1 1...

Страница 6: ...2 1 in 53 mm TM10N NPT 6 5 in 165 mm 3 1 in 79 mm 2 1 in 53 mm TM10B BSP 6 7 in 170 mm 3 1 in 79 mm 2 1 in 53 mm TM15S Spigot 5 4 in 137 mm 3 6 in 91 mm 2 1 in 53 mm TM15N NPT 7 6 in 193 mm 3 8 in 96 mm 2 3 in 58 mm TM15B BSP 7 6 in 193 mm 3 7 in 94 mm 2 2 in 56 mm TM20S Spigot 5 5 in 140 mm 4 1 in 104 mm 2 4 in 61 mm TM20N NPT 7 9 in 200 mm 4 4 in 112 mm 3 5 in 89 mm TM20B BSP 7 8 in 198 mm 4 2 i...

Страница 7: ...on to metal connections is not recommended Install as follows 1 Plan to install turbine with a minimum straight pipe length as follows see Figure 2 Upstream from the turbine allow a minimum straight pipe length of 10 times the internal diameter of the turbine Downstream from the turbine allow a minimum straight pipe length of 5 times the internal diameter of the turbine 2 For Spigot Pipe End use o...

Страница 8: ...ous full stream 3 Check the volume against the display or recording equipment If the amount metered is accurate further calibration is not necessary If not refer to the Q9 Owner s Manual Non Agency Field Calibration Section for further instructions see below NOTE Make sure you meet the meter s minimum flowrate requirements You can download the Q9 Owner s Manual Non Agency here or visit FLOMECmeter...

Страница 9: ...oves freely Keep the meter clean and free of contaminants If the rotor does not turn freely apply a penetrating lubricant on the rotor shaft and bearings Remove any debris or deposits from the rotor using a soft brush or small probe Be careful not to damage the turbine rotor or supports Blowing compressed air through the turbine assembly could damage the rotor Do not allow liquids to dry inside th...

Страница 10: ...ase date PARTS ACCESSORIES LIST FOR TM SERIES METERS Part Number Description 116000 1 Calibration container Large 5 gallon 901002 52 Seal 113435 10 Conditioned Signal Module GEN 2 125060 10 Pulse Access External Power Scaled Module GEN 2 125100 10 4 20mA Module IMPORTANT Please contact GPI before returning any parts It may be possible to diagnose the trouble and identify needed parts in a telephon...

Страница 11: ...11 GETTING STARTED SAFETY SPECIFICATIONS ASSEMBLY INSTALLATION OPERATION CALIBRATION MAINTENANCE REPAIR NOTES ...

Страница 12: ...eceipt This warranty shall not apply if A the product has been altered or modified outside the warrantor s duly appointed representative B the product has been subjected to neglect misuse abuse or damage or has been installed or operated other than in accordance with the manufacturer s operating instructions To make a claim against this warranty contact the GPI Customer Service Department at 316 6...

Отзывы: