INSTALLATION

Before  installing  your  meter,  review 

the  safety  instructions  given  above

 

Examine  your  meter  to  make  sure 

there are no visible signs of shipment 

damage

  Plan  your  meter  installation 

by reviewing the following procedures

 

Your  system  must  be  mounted  on  a 

vented  tank

  If  the  tank  is  unvented, 

your  local  dealer  or  distributor  can 

supply a pressure cap

If the meter is located in a rigid piping 

system  where  the  fluid  is  trapped 

(for  example,  by  gravity,  valves  or 

nozzles) thermal expansion of the 

fluid 

can  create  pressure  spikes  that  can 

damage a meter

 Install a thermal relief 

valve  or  otherwise  allow  for  thermal 

expansion of the fluid�

The 

flowmeter 

MUST be mounted so 

that the rotor shafts are in a horizontal 

plane

  Mounting  the  meter  with  the 

mechanical display facing horizontally 

will  orient  the  rotor  shafts  correctly

  

The mechanical display should never 

face  upwards  or  toward  the  ground

 

The  weight  of  the  rotors  must  be 

supported by the horizontal rotor shafts

 

If  installed  incorrectly,  performance, 

life  or  accuracy  could  be  affected

  

(

see Figure 1

)

Liquid can 

flow 

in a horizontal direction, 

or a vertical direction, but in each case 

the rotor shafts must be in a horizontal 

plane

It is preferred to install the 

flow-meter 

upstream of a 

flow 

control or shut-off 

valve, as the back pressure provided 

by the valve will be 

beneficial 

to system 

accuracy

    The  flow  meter  should 

remain full of liquid at all times when 

connected

Do not operate the flow-meter dir

ectly 

discharging to the atmosphere

Prior to installation, determine whether 

horizontal or vertical flow is r

equired

For vertical 

flow 

installations the liquid 

should travel from bottom to top, i

e

 

it  should  rise  vertically  through  the 

fl

ow-meter

  This  will  ensure  that  the 

flow-meter 

remains  full  of  liquid,  and 

will prevent air entrapment in the meter

The  back  of  the  meter  housing  is 

embossed with “INLET” and “OUTLET” 

adjacent to its respective port to assist 

in correct piping connections

figure 1

Correct

Horizontal Flow

Vertical Flow

InCorrect

Correct

Содержание GPRO QM Series

Страница 1: ...s 7 Informative Table Diesel 8 Informative Table Unleaded 9 Illustrated Parts List 10 Parts and Service 15 TABLE OF CONTENTS SAVE THESE INSTRUCTIONS QM Series Positive Displacement Fuel Meter Owner s Manual Great Plains Industries Inc is a member of the Petroleum Equipment Institute Victor Lukic President Great Plains Industries Inc ...

Страница 2: ...ly with thin viscosity petroleum fuels such as gasoline gasoline ethanol blends E15 maximum diesel and kerosene b The non UL Approved version of this meter is for use only with diesel fuel and kerosene 2 DANGER Observe precau tions against fire or explosion when dispensing fuel Do not operate the meter in the presence of any source of ignition including running or hot engines lighted cigarettes or...

Страница 3: ...eight of the rotors must be supported by the horizontal rotor shafts If installed incorrectly performance life or accuracy could be affected see Figure 1 Liquid can flow in a horizontal direction or a vertical direction but in each case the rotor shafts must be in a horizontal plane It is preferred to install the flow meter upstream of a flow control or shut off valve as the back pressure provided...

Страница 4: ...e installed when operating the meter otherwise particles may enter the meter chamber and disrupt the smooth operation of the oval gears 2 Wrap threaded male connections with thread tape or use a pipe sealant compound compatible with petroleum fuels 3 Install the meter on the pump us 4 Install hose nozzle or filter onto the system and tighten OPERATION ALWAYS FOLLOW SAFETY PRECAUTIONS WHEN OPERATIN...

Страница 5: ...utlet modular filter adapter o rings bolts filter The QM40 includes adapter plates o rings and bolts for use with threaded pipe Without the inlet adapter plate the QM40 can be bolted directly to the outlet of a GPI or GPro pump featuring a modular outlet Bolt modular accessories to the outlet of the QM40 or use the outlet adapter plate for threaded pipe Use a GPI modular filter adapter to include ...

Страница 6: ...e been adjusted at the factory The gasoline setting is approximately fully closed turn clockwise Do not overtighten the screw against the seat figure 5a 5 Reinstall the plate 4 screws and the O ring seal if removed Tighten 4 screws to 42 46 lb in 4 7 5 2 N m torque MAINTENANCE The meter s strainer should be cleaned at regular intervals especially if reduced flow is encountered Clean or Replace Str...

Страница 7: ... strainer Jammed rotors from foreign material in rotor assembly Remove and clean rotor assembly Other system components malfunctioning Check all system components tank to nozzle for clogs and or malfunctions Repair as necessary C Fuel leakage Leakage between coverplate and housing Remove coverplate and inspect for damaged missing or incorrectly seated seal Replace as required Leakage at fittings R...

Страница 8: ...ror Display 0 01 Dispensed Amount 100 0 1 Dispensed Amount 100 Operating Temperature 20 F to 125 F 29 C to 52 C Maximum Work ing Pressure 50 PSIG 3 4 Bar Wetted Materials Housing Cover Fittings Aluminum Rotors PPS Polyphenylene Sulfide Shafts Strainer Stainless Steel Seals NBR Nitrile Butadiene Rubber Mag Drive Acetal Stainless Steel and Neodymium Nickel Plated Inlet Outlet Ports 1 NPT female 1 NP...

Страница 9: ... 5 10 15 20 25 30 35 40 PRESSURE DROP PSI ERROR FLOWRATE GPM QM240 QM40 ACCURACY PRESSURE DROP vs FLOWRATE DIESEL FACTORY SETTING NOMINAL UPPER RANGE FACTORY SETTING NOMINAL LOWER RANGE CALIBRATION SCREW IN CALIBRATION SCREW OUT 2 TURNS PRESSURE DROP ...

Страница 10: ...will adjust entire flow curve up 1 5 0 0 5 1 1 5 2 2 5 3 3 5 4 4 5 5 1 5 1 0 0 5 0 0 0 5 1 0 1 5 2 0 0 5 10 15 20 25 30 35 40 PRESSURE DROP PSI ERROR FLOWRATE GPM QM240 QM40 ACCURACY PRESSURE DROP vs FLOWRATE UNLEADED SCREW IN ORIGINAL EQUIPMENT SCREW IN WITH GEAR KIT SCREW OUT 2 TURNS WITH GEAR KIT PRESSURE DROP ...

Страница 11: ...11 NOTES ...

Страница 12: ...12 K L A B C B C F G H I J N ILLUSTRATED PARTS LIST K For QM40 ...

Страница 13: ...1 rotor set G 139500 07 KIT COVERPLATE ASSEMBLY GAL Includes 1 assembled coverplate gears mag drives housing seal at taching hardware H 139500 08 KIT COVERPLATE ASSEMBLY LITRE Includes 1 assembled coverplate gears mag drives housing seal at taching hardware ITEM PART NO DESCRIPTION I 139500 09 KIT CALIBRATION SCREW Includes 1 calibration screw 1 O ring J 139500 10 KIT BACK PLATE Includes 1 back pl...

Страница 14: ...14 D E K L M C H ILLUSTRATED PARTS LIST ...

Страница 15: ... Includes 1 counter assembly attach ing hardware K 139500 11 KIT TOP COVER GALLON Includes 1 top cover w gallon decal attaching hardware L 139500 12 KIT TOP COVER LITRE Includes 1 top cover w litre decal attaching hardware M 139500 13 KIT MIDDLE COVER Includes 1 middle cover attaching hardware 139500 15 KIT UNLEADED FUEL QM240 Not shown ...

Страница 16: ...anty work always be prepared with proof of purchase date Please contact GPI before returning any parts It may be possible to diagnose the trouble and identify needed parts without returning parts GPI can also inform you of any special handling requirements you will need to follow covering the transportation and han dling of fuel transfer equipment Before packing for shipment make sure the meter is...

Страница 17: ...l not apply if A the product has been altered or modified outside the warrantor s duly appointed representative B the product has been subjected to neglect misuse abuse or damage or has been installed or operated other than in accordance with the manufacturer s operating instructions To make a claim against this warranty contact the GPI Customer Service Department at 316 686 7361 or 800 835 0113 O...

Отзывы: