background image

STEP 1

Remove shipping plugs from Quad pump ports. Some
water from factory testing may spill out.

STEP 2

Install inlet A and discharge B port connectors. Slide
clips toward rear, install ports and firmly push slide clips
C forward to lock port connectors in place.

STEP 3

Slide rubber mounts fully into 4 mounting tracks.

STEP 4 

Mount pump vertically, with pump head down or
horizontally in an accessible location (pump is not
submersible). If mounting vertically, motor up, attach
motor mounts first, then pump head mounts, while

supporting weight of pump.

STEP 5

Use 3/4”’ I.D. flexible hose (preferably braided or
reinforced). Use hose clamps on the slip-on barb hose
connections. Use of reinforced vinyl hose is recom-
mended.

STEP 6 

Install a Flojet #01610-000 strainer in an accessible
location (for inspection and cleaning) between the bilge
pick up and pump inlet. This strainer or equivalent is

required

for pump warranty to be valid.

STEP 7

Installation of a screen on the bilge pick up will require
less strainer cleaning.

INSTALLATION

STEP I

Use 14 gauge stranded wire to 20’, 12 gauge to 50’,
from power source.

STEP 2

Use a 15 amp rated on-off switch on the (+) positive (red)
motor lead.

STEP 3

Install 15 amp fuse protection on the switched (+)
positive lead for 12 volt -114 model; use 10 amp fuse on
24 volt -314 model; and 5 amp fuse on 32 volt -414
model.

WIRING

Fuse

(+)

Switch

Battery

(–)

Black (–)

Flojet

Bilge Pump

Flojet Inlet

Strainer

B

A

C

Содержание quad II diaphragm 4125 series

Страница 1: ... suction lift vertical distance from bilge pick up to pump inlet The maximum recommended discharge head distance outlet is above pump is 15 feet It is recommended you utilize an automatic on off switch so that the pump is turned off when not in use The Quad II is able to run dry no liquid for extended periods however this could cause needless battery drain OPERATION Pump Series Dimensions Inches m...

Страница 2: ...inforced Use hose clamps on the slip on barb hose connections Use of reinforced vinyl hose is recom mended STEP 6 Install a Flojet 01610 000 strainer in an accessible location for inspection and cleaning between the bilge pick up and pump inlet This strainer or equivalent is required for pump warranty to be valid STEP 7 Installation of a screen on the bilge pick up will require less strainer clean...

Страница 3: ...Set screw head must be positioned facing motor covering seam indentation Positioning of this screw is critical to avoid misalignment and subsequent diaphragm damage Upper Housing Check Valve 6 Reassemble upper housing 1 7 Properly seat O Ring in check valve assembly 2 and check if ferrules and screen are in place on upper housing 1 8 Install check valve 2 into upper housing 1 and push in 9 Assembl...

Страница 4: ...repair or replace this product if found defective with a new or reconditioned product but not to include costs of removal or installation No product will be accepted for return without a return material authorization num ber All return goods must be shipped with transportation charges prepaid This is only a summary of our Limited Warranty For a copy of our complete warranty please request Form No ...

Отзывы: