MOUNTING

The FLOJET G70C self-priming pump should be mounted in a
dry and adequately ventilated area. This pump can be mounted
several feet from the tank, above or below the fluid level. For
most applications, no more than 4 feet above the fluid level is
recommended.  Note: 

This is not a submersible pump.

Secure Pump to desired fixture by inserting screws through the
rubber grommets in the baseplate of the pump. 

Ports must be

facing down.

The pump must be protected by a housing able

to withstand the impact of a steel half ball of 25mm with a mass
of 1Kg and an energy of 7J. Refer to EN 13463-1 Par 13  for
further details.  

HOSE CONNECTIONS

Liquid  In  -  Use  3/8”,  1/2”,  or  3/4”  I.D.  reinforced  hose  or
equivalent.  Avoid  sharp  bends  that  could  restrict  flow  or
cause hose to collapse under vacuum.

Liquid  Out  -  Use  3/8”,  1/2”,  or  3/4”  I.D.  reinforced  hose  for
discharge  tube.  3/4”  I.D.  hose  must  use  90°  elbows  when
using large muffler.

Air In - Make sure air regulator is set at zero. Use reinforced
1/4”  I.D.  hose.  Connect  “Air  In”  to  air  supply  fitting  on
regulator.  If  pumps  are  installed  in  an  enclosed  area,  it  is
recommended  to  connect  a  hose  to  the  air  discharge  port
(exhaust)  and  vent  air  to  atmosphere  (Requires  small
exhaust port PN# 20756103B not included).

PLUMBING

Use  a  flexible  hose  to  avoid
excess stress on pump ports.
DO  NOT  crimp  or  kink  hose.
All  hose  should  be  the  same
size as the pump port fittings.
All  fittings  and  hose  must  be
compatible  with  fluid  being
pumped. It is recommended to use plastic fittings only.

The  use  of  check  valves  in  the  plumbing  system  could
interfere with the priming ability of the pump. If unavoidable,
check  valves  in  the  pumping  system  must  have  a  cracking
pressure of 2 PSI or less.

Use a minimum 40 mesh strainer or filter in the tank or pump
inlet  line  to  keep  large  foreign  particles  out  of  the  system.
Liquid  inlet  port  must  be  equal  to  or  larger  than  the  liquid
outlet port.

OPERATION

At  start-up,  regulate  air  pressure  to  desired  setting.  For
most  installations  20  PSI  (1.4  bar)  inlet  will  be  adequate,
although  DO  NOT  go  below  20  PSI.  Pump  will  operate
according to air supply. Flow and pressure can be adjusted
by  increasing  or  decreasing  air  pressure  to  accommodate
varying  product  viscosities,  length  of  lines  or  other
installation conditions. Review flow curves located on page
1  for  further  assistance.  High  viscosi ty  fluids  and  hose
length will limit priming distance.

Compressors must have dryers and/or a water separator in
the air distribution system. Pumps that fail due to water in
the  air  chamber  will  not  be  covered  under  the  limited
warranty.

Plastic  air  inlet  ports  do  not  have  a  check  valve.  Prior    to
cleaning or servicing, purge the pump by carefully tilting the
pump so ports are facing up and remove suction line from 

source. Turn air off and disconnect air inlet line. (Standard
brass air inlet ports have a check valve).

DISASSEMBLY PROCEDURE

First,  remove  inlet  air  line,  muffler  and  suction/discharge
line  from  the  pump.  This  is  accomplished  by  using  a  flat-
bladed screwdriver to slide the retaining clips away from the
air  inlet,  muffler  and  suction/discharge  fittings  and  pulling
the fittings away from the pump body. Now remove the muf-
fler by sliding the retaining clip away from the muffler base
and pulling the muffler out of the pump body.

Using a Phillips screw driver remove the seven (7) screws
from the front end cap followed by the (7) screws from the
rear end cap. With the front end cap facing up and the rear
end cap facing down on the workbench, position a flat blad-
ed screw driver into the slot located above the muffler port
and just below the pad marked Air/C02 and lift off the front

end cap. The rear end cap can be removed by placing the
flat bladed screwdriver under the fully opened port retaining
clip and lifting off.

Note the position of the suction and discharge valves before
removing them from the pump body. The first diaphragm is
removed  from  the  pump  shaft  by  unscrewing  in  a  counter
clockwise direction. The second diaphragm is removed by
placing the flat tip of a screwdriver into the exposed slot at
the  end  of  the  pump  shaft  and  unscrewing  the  diaphragm
from the shaft. To remove the flange housing, place the tip
of the flat bladed screw driver into the air bleed hole on the
lower  side  of  the  flange  housing  and  lift  up  the  lower  end
separating the flange housing from the pump body.

The slide valve assembly and pump shaft can be removed
by simply pulling them from the pump body. The pump shaft
then can be removed from the slide valve yoke assembly.

REASSEMBLE PROCEDURE

Assemble  the  slide  valve  and  pump  shaft  with  the  yoke
placed between the (2) bumpers on the pump shaft. Install
the  slide  valve/pump  shaft  assembly  into  the  pump  body
making sure the O-rings in the slide valve are in place. To
install  the  flange  housing,  prelube  the  o-ring  with  Parker
Super  “O”  Lube  and  install  on  flange  housing  and  place
housing  over  the  pump  body  aligning  the  flange  housing
with the pump body ribs pressing it into place.

Install the first diaphragm and O-ring on to the pump shaft
by  threading  on  to  shaft  using  a  flat  blade  screwdriver  to
hold the pump shaft until the diaphragm is tight. Install the
second diaphragm and O-ring on to the pump shaft turning
clockwise until tight.

Install the suction valves with springs facing into the pump
body and the discharge valves with the springs facing out.
See  arrows  on  pump  rear  end  cap  below  suction  and
discharge ports.

Install the port retainer clips (large) into the pump end cap
(mounting  base)  and  install  the  seven  (7)  Phillips  screws
into pump body and cross tighten until snug and then cross
torque  to  22-24  inch  pounds.  Install  port  retaining  clips
(small) into the pump body with tabs facing out. Position the
front end cap and install the seven (7) Phillips screws into
pump  body  and  cross  tighten  until  snug  and  then  cross
torque to 22-24 inch pounds.

Install  the  muffler  in  the  center  port  by  pushing  it  in  and
sliding  the  retainer  clip  into  place.  Install  the  suction  and
discharge  ports  and  the  air  inlet  port  fitting  and  slide  the
retainer clips in place. Check for leaks.

FLEXIBLE

HOSE

RIGID

PIPE

Содержание G70C Series

Страница 1: ...t Allowed fluids for Kalrez parts Kalrez parts Lubricating Oils Halogenated Solvents Hydraulic Oils Vegetable Oils Alcohols Keytones Aromatic Hydrocarbons Aliphatic Hydrocarbons Diluted Acids Alkalis Soaps with solvents Automotive brake fluid Acetones Ethanol inks MARKS AND GENERAL INFORMATION In complicance with the 94 9 CEE standards the pumps carry the following identification marks II 2G c IIB...

Страница 2: ...is is accomplished by using a flat bladed screwdriver to slide the retaining clips away from the air inlet muffler and suction discharge fittings and pulling the fittings away from the pump body Now remove the muf fler by sliding the retaining clip away from the muffler base and pulling the muffler out of the pump body Using a Phillips screw driver remove the seven 7 screws from the front end cap ...

Страница 3: ...ODED VIEW MODEL NUMBERING MATRIX Part No Description Qty 20381100 1 2 HB 90 Elbow 2 20381101 3 4 HB 90 Elbow 2 21000663 1 2 OD John Guest 2 21000664 3 8 OD John Guest 2 01510000 1 4 HB Straight Brass Air In Buna O Ring 2 20325033 1 4 HB Straight Plastic Air In Buna O Ring 2 20756103B Air Exhaust Port x 1 4 HB O ring 12 Polypropylene Viton G70C PORT FITTINGS All liquid fittings include Viton Extrem...

Страница 4: ...eak or break in the product inlet line 1 Replace product line 2 A leak or break in the product discharge line 2 Replace product line Pump leaks through exhaust port 1 Leak at upper exhaust port o ring 13 1 Replace exhaust port 13 2 Shaft seal o rings damaged or worn 2 Replace shaft seal o rings 3 Inadequate slide lubrication 3 Replace with shuttle valve kit Flow rate is low 1 Tubing or hose is dam...