FLOJET 2100-12 Скачать руководство пользователя страница 2

STEP 1 

Remove shipping plugs from pump ports. Some water
from factory testing may spill out.

STEP 2

Install inlet A and discharge B port connectors.

STEP 3 

Insert rubber mounting grommets onto base plate.

STEP 4 

Mount pump vertically, with pump head down or
horizontally in an accessible location. Do not compress
grommets.

STEP 5

Use 1/2” or 3/8” I.D. flexible hose (preferably braided or
reinforced). Use hose clamps on the slip-on barb hose
connectors.

STEP 6

Install no less than 3/8” I.D. hose for feed lines to
fixtures. Use high pressure hose on all city water lines.

STEP 7

Install a Flojet strainer in an accessible location (for
inspection and cleaning) between the tank and pump
inlet. This strainer or equivalent is required for pump
warranty to be valid.

INSTALLATION

In an easily accessible location, install a switch to
control electricity to the pump. Turn the pump off when
not in use for extended periods, or when tank is out of
water.

A 7 amp. fuse should be installed in the positive line with
the pump being its only load. (24V model, use 5A fuse).

Wire size based on total wire length.

0 - 20 ft.

#16 AWG

20 - 50 ft. 

#14 AWG

50 - 80 ft.

#12 AWG

WIRING

(+)

Red (+)

Fuse

Switch

Battery

(–)

Black (–)

Pumpgard

Wat

er

Tan

k

Jabs

co

City

Wat

er

Entr

y

Wat

er

Hea

ter

Che

ck

Valv

e

TM

B

A

Flojet Shower

Drain Pump

Install Strainer

Inlet Side Only

AUTOMATIC WATER SYSTEM INSTALLATION

SHOWER DRAIN INSTALLATION

Model 2100-694