background image

 

WARNING

 - Read and follow all instructions in this IOM manual and on the equipment. Failure 

to follow instructions can cause severe injury and/or death.

 

WARNING

 – 

Risk of Electric Shock . 

All electrical wiring MUST be in conformance with 

applicable local codes, regulations, and the National Electric Code (NEC). Hazardous voltage can 
shock, burn, and cause death or serious property damage. To reduce the risk of electric shock, do 
NOT use an extension cord to connect unit to electric supply. Provide a properly located electrical 
receptacle. 

Before working on any electrical equipment, turn off power supply to the equipment .

 

WARNING

 – To reduce the risk of electric shock replace damaged wiring immediately. 

 

WARNING

 – Ground all electrical equipment before connecting to electrical power supply. 

Failure to ground all electrical equipment can cause serious or fatal electrical shock hazard.

 

WARNING

 – Do NOT ground to a gas supply line.

 

WARNING

 – To avoid dangerous or fatal electrical shock, turn OFF power to all electrical 

equipment before working on electrical connections.

 

WARNING

 – Failure to bond all electrical equipment to system structure will increase risk for 

electrocution and could result in injury or death. To reduce the risk of electric shock, see installation 
instructions and consult a professional electrician on how to bond all electrical equipment. Also, 
contact a licensed electrician for information on local electrical codes for bonding requirements.

 

CAUTION

 – Potential pinch point. Equipment connected to or driven by this device may start 

unexpectedly and may cause personal injury or entrapment in linkage systems. 

Basic safety precautions should always be followed, including the following: Failure to follow instructions 
can cause severe injury and/or death.

 This is the safety-alert symbol. When you see this symbol on your equipment or in this manual, look 

for one of the following signal words and be alert to the potential for personal injury.

 

WARNING

 warns about hazards that could cause serious personal injury, death or major property 

damage and if ignored presents a potential hazard.

 

CAUTION

 warns about hazards that will or can cause minor or moderate personal injury and/or 

property damage and if ignored presents a potential hazard. It can also make consumers aware of 
actions that are unpredictable and unsafe.  

 

   A notice indicates special instructions that are important but not related to hazards.

 Notice:

IMPORTANT SAFETY INSTRUCTIONS

USE ONLY FLO-TITE GENUINE REPLACEMENT PARTS

ELo Rev C   ECR 044V

 

Page 

2

 of 28 

Back to TOC

www.flotite.com

Содержание PRO-torQ ELO Series

Страница 1: ...LACEMENT PARTS ELo Rev C ECR 044V Page 1 of 28 TO PREVENT POTENTIAL INJURY OR DAMAGE TO PROPERTY READ THIS MANUAL CAREFULLY AND COMPLETELY INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS ELO Serie...

Страница 2: ...sult in injury or death To reduce the risk of electric shock see installation instructions and consult a professional electrician on how to bond all electrical equipment Also contact a licensed electr...

Страница 3: ...dels with battery backup and local control capabilities The various models might seem to be easily adaptable across any site or design intent but are actually very specific as to how they interface to...

Страница 4: ...l On Off or Proportional Ambient Operating Range 22 F to 158 F 30 C to 70 C Humidity Range 0 95 RH Altitude Limit 9850 ft 3000 m Below are Terms and Definitions used throughout this manual 1 XTS TS pr...

Страница 5: ...or without power Turn the handwheel CW to make the output drive move CW when viewed from above Turning the handwheel CCW makes the output drive turn CCW WARNING To avoid dangerous or fatal electrical...

Страница 6: ...ve a terminal block from the PCB receiver pullstraightOUTinadirection parallel to the PCB Use caution when reinserting block make sure all pins are aligned before seating Torque Switch TS equipped pro...

Страница 7: ...power to the motor when a high torque event occurs Torque Switch Normal Mode 1 In normal operating mode the torque switch and drive cam are in the neutral position shown in the photo 2 Internal gearin...

Страница 8: ...a sharp 2 5mm hex key to free up the cam set screw Take care not to let the hex key slip at this stage it can easily strip out Once it is free adjust it as described below Rotate the hex key to the R...

Страница 9: ...or to your required CCW position Keep all changes within 3 degrees of the factory setting Adjust CCW Cam Second from Bottom 4 Cam 2 is the second cam up from the bottom green and is the end of travel...

Страница 10: ...w rides along the camshaft Now SLOWLY rotate the hex key to the LEFT pushing the cam until you hear the click on the bottom switch Continue to rotate the cam between 3 and 5 degrees to the LEFT to mak...

Страница 11: ...hrough its full travel from full CW to full CCW and back again to check for any possible interference Do NOT utilize any mechanical advantage devices to rotate the handwheel pipes wrenches extension b...

Страница 12: ...MAIN TERMINAL BLOCK B No connections are made to the proportional control board directly 8 Set the jumper headers for correct signal IN and OUT ref next page 9 Rotate the potentiometer pinion gear to...

Страница 13: ...Signal IN Connection to Main Term Block L2 Neu L1 Hot Feedback Select Input Select 2 10vdc TOP 2 4 20mA BOT 2 4 20mA TOP 2 2 10vdc BOT 2 DEFAULT Make all connections to the MAIN terminal block ONLY P...

Страница 14: ...CW before tightening the two M3 setscrews on the sector drive gear 10 Apply correct power according to the actuator model A The blue LED D1 will turn on and grn LED STA will turn on 11 Press the SET...

Страница 15: ...m Fault OUT Dry Contact DIP ON OFF FUNCTION 1 4 20mA 0 2 10V Input 2 0 10V 2 10V 4 20mA 3 4 20mA 0 2 10V Feedback 4 0 10V 2 10V 4 20mA 5 Mod On Off Control DIP FUNCTION 4 Off Factory Function 4 On Fac...

Страница 16: ...T shaft rotates in a CCW direction as viewed from above and stops at the full CCW Open position 6 Measure terminals 5 and 6 to read 20mA 10vdc 7 Read continuity between terminals C D to show the CCW A...

Страница 17: ...ST be secure and set according to the procedures in the Adjusting CW CCW End of Travel section Motor is extremely hot to the touch Control noise or excessive duty cycle Check for stray voltage uctuati...

Страница 18: ...that of the actuator Increase actuator size With the actuator removed from the mechanical equipment manually rotate the valve or damper through its intended range of travel to check for mechanical pro...

Страница 19: ...123 3 11 79 8 50 216 4 73 120 9 45 240 0 669 17 1 38 35 4 M8 1 25 X 20mm Deep F07 2 756 70 4 7 120 12 5 turns 90 24 5 11 Elo NB9 10 45 265 6 150 4 85 123 3 11 79 8 50 216 4 73 120 9 45 240 0 669 17 1...

Страница 20: ...ng System Manual Override Handwheel Inside the actuator Easily accessible switch cam stacks Modular Control Cards including internal heater 2 position 3 position proportional control custom interfaces...

Страница 21: ...e sizing data is provided in the table below to assist in the selection of the proper wire size for HRSN3 Series actuators using various wire sizes over distance Be sure to reference the correct volta...

Страница 22: ...switches bypassed in the diagrams On Off Control Torque Switches Battery Backup LCS Elo NA8C Elo NB9 12vdc On Off Elo NA8B Elo NB9 12vac On Off 12VAC VDC On Off Control WIRING DIAGRAMS USE ONLY FLO TI...

Страница 23: ...ssed in the diagrams Proportional Control Torque Switches Battery Backup LCS Elo NA8C8 Elo NB0 12vdc Proportional Elo NA8B8 Elo NB9 12vac Proportional WIRING DIAGRAMS 12VAC VDC Proportional Control US...

Страница 24: ...switches bypassed in the diagrams On Off Control Torque Switches Battery Backup LCS Elo NA8D Elo NB5 24vdc On Off Elo NA8E Elo NB9 24vac On Off 24VAC VDC On Off Control WIRING DIAGRAMS USE ONLY FLO TI...

Страница 25: ...ssed in the diagrams Proportional Control Torque Switches Battery Backup LCS Elo NA8F8 Elo NB9 24vdc Proportional EloNA8E8 Elo NB9 24vac Proportional 24VAC VDC Proportional Control WIRING DIAGRAMS USE...

Страница 26: ...tches bypassed in the diagrams On Off Control Torque Switches Battery Backup LCS Elo NA8K0 Elo NB9 120vac On Off Elo NA8L0 Elo NB9 230vac On Off 120 230VAC On Off Control WIRING DIAGRAMS USE ONLY FLO...

Страница 27: ...passed in the diagrams Proportional Control Torque Switches Battery Backup LCS Elo NA8K8 120vac Proportional Elo NA8L8 Elo NB9 230vac Proportional 120 230VAC Proportional Control WIRING DIAGRAMS USE O...

Страница 28: ...This page intentionally left blank www flotite com...

Отзывы: