TTCF-9A 

Variable High Flow Heated 

Hydraulic Component Flusher

 

40201409 

QUICK START 

INSTRUCTIONS 

 

Flo-Dynamics, Inc.  •  3300 Reedy Drive  •  Elkhart, IN 46514  •  800-303-5874

 

 

 

 

          

       

Page 

3

 of 

5

 

Press START/PAUSE and check the following: 

o

 

Secure fill cap 

o

 

Secure filter screen 

o

 

Check fluid level 

o

 

Check all connections 

o

 

Set flow rate 

o

 

Set flow direction 

Press the START/PAUSE button to start the flush cycle. 
At the end of a flush cycle, the flusher will stop and signal 

with an audible sound. The display will show “FLUSH 

COMPLETE” with before and after flush cycle results.  
Press the manual air purge button to clean out the lines. 
Remove the top half of the filter housing, note debris on 

filter screen, clean the screen, and reassemble the filter 

housing. 
Note: Always use the manual air purge button prior to 

removing the top portion of the screen filter housing to 

clean out the cooler system and service hoses. 
Note: A flush cycle time can be changed anytime by 

pressing the RUN TIME button to select a different flush 

cycle time. 
Repeat until desired system cleanliness is achieved. 

 

 

 

 

Use the manual air purge button to clean out the cooling 

system and service lines with the Reverser Valve in either 

flow direction, then place in bypass (middle) position. 
Remove the service hoses from the system being cleaned, 

and use the “U” adapter to connect the hoses together.  
Clean the filter screen and reassemble for the next 

cleaning. 
Move the Flow Control Valve to a minimal flow position. 
Unplug the flusher and disconnect shop air. 
 

 

 

 

 

 

 

 

 

 

 

 

Содержание TTCF-9A

Страница 1: ...follow instructions to prevent potential injury FLUSH PROCEDURE Fill the tank with 9 gallons of hydraulic fluid Check the level with the dipstick without threading in to ensure the fluid level is between the high and low level marks WARNING DO NOT OVERFILL or run with fluid level above the high level mark Plug the machine into a 20A grounded circuit without anything else plugged in or being used o...

Страница 2: ...em Use the MODE button to select START FLUSH Use the RUN TIME button to select the flush cycle time It is suggested that the initial flush runs for 15 minutes to capture initial contaminants within the cooler system Press START PAUSE and check the following o Secure fill cap o Secure filter screen o Check fluid level o Check all connections o Set flow rate o Set flow direction Press the START PAUS...

Страница 3: ...ousing note debris on filter screen clean the screen and reassemble the filter housing Note Always use the manual air purge button prior to removing the top portion of the screen filter housing to clean out the cooler system and service hoses Note A flush cycle time can be changed anytime by pressing the RUN TIME button to select a different flush cycle time Repeat until desired system cleanliness...

Страница 4: ...ns only drain tank when fluid is below 100 degrees Connect the drain hose adapter to the red service hose Move the Reverser Valve toward the red service hose Place the drain hose adapter into a suitable waste container Move the Flow Control Valve to position 3 CAUTION Make sure the flow rate is set to a low level to prevent a high fluid flow into the waste container Use the MODE button to select S...

Страница 5: ...ve Elkhart IN 46514 800 303 5874 Page 5 of 5 COMPLETELY DRAIN THE TANK FOR FLUID TYPE CHANGE Perform the Drain Tank Using Override Level Sensor Mode procedure above Place a suitable waste container below the inlet T Remove the pipe plug on the inlet T and use the handle to tilt the unit to drain the remaining fluid in the tank ...

Отзывы: