background image

 

 

Safety & Installation Guide  

 

 

Version: 01.12 

 

Valid from 22.10.2018 

 

FG2P1-4S1P00/1 

 

10 

This manual 

applies only on Flisom’s eFlex Series modules 

 

 

 

 

 

 

 

 

 

2.  Remove 15cm of the white protective foil on the short side with the junction box 

 

 

 

 

 

 

 

 

 

 

 

3.  Put the module on the marked position and press it on the roof with a rubber roller. 

 

 

 

 

 

 

 

 

 

 

Содержание eFlex 2x1

Страница 1: ...Safety Installation Guide Version 01 12 Valid from 22 10 2018 FG2P1 4S1P00 1 1 This manual applies only on Flisom s eFlex Series modules Flisom eFlex Series Safety Installation Guideline for eFlex...

Страница 2: ...4 Technical Information 13 5 Operation 14 6 Inspection and Maintenance 14 7 Disposal 14 8 Disclaimer 14 9 Information 14 9 1 Third Party Supplier Information 15 Warning Flisom eFlex PV Modules are ele...

Страница 3: ...electrical fire and other codes and regulations in addition to the specific recommendations stated in this manual The Flisom eFlex Series modules are not intended for self installation by end users T...

Страница 4: ...rubbing materials for cleaning the modules Do not use sharps objects Do not walk on the panels if there is any risk that sharp stones under the soles or sharp shoe elements would damage the panel The...

Страница 5: ...nds to use personal protective equipment such as safety gloves safety googles and safety boots etc Respect general safety rules 3 1 Environment Ambient temperature to install Flisom eFlex Series modul...

Страница 6: ...Flex Series modules receive the same amount of direct sunlight within the same string taking in account their orientation and shadowing If direct shadow on active surface could not be avoided Orientat...

Страница 7: ...necessary GAF TPO ask supplier if primer is necessary Stevens TPO ask supplier if primer is necessary Johns Manville TPO ask supplier if primer is necessary Rubber membrane Carlisle EPDM ask supplier...

Страница 8: ...instructions If a roof is damaged it has to be replaced before installation of the modules To clean a TPO EPDM or metal roof use IPA 2 propanol isopropyl alcohol and lint free wipes The cleaning shou...

Страница 9: ...ex modules Leave enough space between module strings for the cable duct Check that the cable duct is not shading the modules Cover the Junction box with the cable duct system for additional UV protect...

Страница 10: ...10 2018 FG2P1 4S1P00 1 10 This manual applies only on Flisom s eFlex Series modules 2 Remove 15cm of the white protective foil on the short side with the junction box 3 Put the module on the marked p...

Страница 11: ...the area around the junction box and the junction box on the roof 5 Remove slowly the rest of the white protection foil and press the module simultaneously with a rubber roller on the roof Always rol...

Страница 12: ...ompatible connector types which are authorised from both producers Use solar cables for outside use 2 5 to 4mm and min 90 C Check that no cable is under tensile stress or bended over a sharp edge Secu...

Страница 13: ...6m eFlex 2 3m eFlex 3 1m Nominal power PMPP W 30 55 85 110 Tolerance of nom power P W 0 5 0 5 0 5 0 5 Voltage at nom power VMPP V 34 35 37 36 Current at nom power IMPP A 0 88 1 54 2 29 3 06 Open circ...

Страница 14: ...odules must be disposed of in a responsible manner Please contact your local supplier or disposal company for further information For health and safety reasons Flisom eFlex Series modules should not b...

Страница 15: ...Safety Installation Guide Version 01 12 Valid from 22 10 2018 FG2P1 4S1P00 1 15 This manual applies only on Flisom s eFlex Series modules 9 1 Third Party Supplier Information...

Страница 16: ...Safety Installation Guide Version 01 12 Valid from 22 10 2018 FG2P1 4S1P00 1 16 This manual applies only on Flisom s eFlex Series modules...

Отзывы: