Figure 7.8
Isotherm Alarm examples.
7.6
Measurements Menu
Figure 7.9
Accessing the Measurements mode menu.
Navigate to the Measurement icon and press Menu. Select from the
available options, detailed below, and then press Menu to confirm.
• Centre Spot
. Position the camera to target a surface spot with the
cross-hairs to measure its temperature. The temperature measurement is
shown in the upper left corner of the display (digitally).
• Hot Spot
. Position the camera so that the rectangle display target is cov-
ering an area of interest. The cross-hairs will move to the hottest (MAX)
spot automatically (inside the rectangle target). The MAX temperature is
shown, digitally, in the upper left corner.
• Cold Spot
. Position the camera so that the rectangle display target is
covering an area of interest. The cross-hairs will move to the coldest (MIN)
spot automatically (inside the rectangle target). The MIN temperature is
shown, digitally, in the upper left corner.
• No Measurements.
#NAS100060; r. AA/71942/71942; en-US
17