background image

Maintenance

9

9.1

Cleaning

Wipe the housing with a damp cloth as needed. Do not use abrasives or sol-
vents. Clean the lenses with a high-quality lens cleaner.

9.2

Battery Considerations and Service

The rechargeable lithium battery is not user-serviceable. Please contact FLIR
support for service instructions: https://support.flir.com.

For best results, charge the battery immediately after seeing a low battery in-
dication using the supplied USB-C cable (with an AC wall charger, not sup-
plied). If the battery is allowed to fully drain, allow 2~3 hours before the
charging display appears after connecting to an AC charger. a full charge
(100%) requires 6 hours, a charge to 90% power requires 4 hours. Charging
through a PC USB port is not recommended.

If the camera is not going to be used for an extended period (> 3 months), it
should be charged to 70% then stored at room temperature and recharged
every 6 months. Failure to do so may result in a battery that cannot be re-
charged and that therefore will require service.

9.3

Reset the Camera

If the camera display freezes or if the camera in any way stops operating nor-
mally, press and hold the up and down buttons for at least 10 seconds. Re-
lease the buttons when the camera switches OFF. After the device switches
OFF, switch it back ON again to resume use. No data will be lost by resetting
the camera. If problems persist, contact FLIR for support.

#NAS100014; r. AA/59807/59807; en-US

23

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание TG267

Страница 1: ...USER MANUAL Automotive Diagnostic Thermal Camera Models TG267 and TG297 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...USER MANUAL Automotive Diagnostic Thermal Camera NAS100014 r AA 59807 59807 en US iii www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 3: ...isible Spectrum Camera 10 5 6 Capturing and Working with Images 10 6 Programming Menu System 12 6 1 Menu System Basics 12 6 2 Main Menu 12 6 3 Settings Sub Menu 14 7 Bluetooth Communication and FLIR T...

Страница 4: ...ions 27 10 12 Data Communication and Interface Specifications 27 10 13 Rechargeable Battery Specifications 27 10 14 Environmental Specifications 27 10 15 Physical Specifications 29 10 16 Included Equi...

Страница 5: ...2 Quality Assurance The Quality Management System under which these products are developed and manufactured has been certified in accordance with the ISO 9001 standard FLIR Systems is committed to a...

Страница 6: ...le spectrum camera to the IR image to help you diagnose problems 3 presets and 1 custom emissivity setting LED Work light Laser pointer and cross hair display for easy targeting of measurement spot Ty...

Страница 7: ...Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure CAUTION Use extreme caution when the Laser pointer is on CAUTIO...

Страница 8: ...press 5 Lanyard post 6 Accessory mount 7 High temperature lever switch TG297 8 160 x 120 pixel Lepton IR camera 9 Laser pointer with circular target spot assist 10 USB C and Thermocouple jack compartm...

Страница 9: ...enus Press to activate the Laser pointer TRIGGER Pull trigger to capture camera image Pull trigger to exit the menu system 4 3 Display Description Figure 4 2 Display Description 1 Menu area 2 Date and...

Страница 10: ...enter spot cross hairs 9 Laser Pointer active 10 Center spot temperature measurement 11 Thermocouple measurement TG267 NAS100014 r AA 59807 59807 en US 6 www GlobalTestSupply com Find Quality Products...

Страница 11: ...APO time Use the menu system under Device Settings To set the APO timer See Sec tion 6 Programming Menu System for more information 5 2 IR Camera and Thermometer Figure 5 1 Combined Thermal and Visibl...

Страница 12: ...system under Image Adjustments Colors Figure 5 2 Laser pointer with temperature measurement spot 5 3 High Temperature Switch TG297 1 To access the high temperature mode of the TG297 slide the lever t...

Страница 13: ...mperature readout 33 7 in this example 1 If necessary enable the thermocouple mode in the menu system under Measurement The thermocouple is enabled when the TC label is shown on the display 2 Connect...

Страница 14: ...he power button to switch the camera ON 2 Select the Visible Image mode in the menu system under Image Adjust ments Image Mode 3 Point the camera toward the test area and scan as desired 4 View the im...

Страница 15: ...the selected image or all of the stored images Press CAN CEL to return to the previous screen 5 You can send images to a mobile device using Bluetooth see Section 7 Bluetooth or you can transfer image...

Страница 16: ...GALLERY Press MENU to access the stored images Use the arrow but tons to scroll through the stored images and use the MENU button to open an image Press MENU at an opened image to see the SEND CANCEL...

Страница 17: ...adjust the MSX alignment so that the thermal image and the visible image are aligned accurately While viewing the THERMAL PLUS VISIBLE IMAGE screen in the menu press MENU to access the MSX adjustment...

Страница 18: ...or palette Iron Rainbow White hot Black hot Arctic or Lava Press MENU to confirm selection SETTINGS Press MENU to access the Settings sub menu see below 6 3 Settings Sub Menu MEASUREMENT NAS100014 r A...

Страница 19: ...80 and 0 60 and use the MENU button to select a preset Choose the Custom Value utility last se lection on the list to select a specific emissivity value At the Custom Val ue setting press MENU and th...

Страница 20: ...details 2 Laser Press MENU to enable disable the Laser pointer When enabled you can use the Laser pointer button to switch ON the Laser pointer 3 Screen brightness Use the arrows to select the desired...

Страница 21: ...Never to disable APO GENERAL SETTINGS 1 Temperature Unit Use the arrows and the MENU button to select C or F 2 Time Date Use the arrows to scroll and the MENU button to set the Time Date Time Format a...

Страница 22: ...Number Software Level Revision Battery status and remaining Internal Storage Capacity GENERAL SYSTEM INFO Press MENU to view compliance information FACTORY RESET Follow the prompts to reset the User...

Страница 23: ...Programming Menu System 6 NAS100014 r AA 59807 59807 en US 19 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 24: ...his equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against h...

Страница 25: ...or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NAS100014 r AA 59807 59807 en US 21 www GlobalTestSupply com Fi...

Страница 26: ...amera to be updated The update file Refer to the steps in the next section 8 1 System Firmware Update 1 Visit https support flir com to obtain a firmware update file 2 Select the Downloads tab and the...

Страница 27: ...charge to 90 power requires 4 hours Charging through a PC USB port is not recommended If the camera is not going to be used for an extended period 3 months it should be charged to 70 then stored at r...

Страница 28: ...ocus Fixed Image frequency 8 7 Hz 10 2 Detector Specifications Focal plane array Spectral response range Uncooled microbolometer 7 5 14 m Detector pitch 12 m 10 3 Image Presentation Specifications Dis...

Страница 29: ...1 of reading or 2 1 whichever is greater Response time 150 ms IR thermometer measurement Continuous scanning Minimum measurement distance 0 85 ft 0 26 m 10 5 Measurement Analysis Specifications Spot...

Страница 30: ...ets plus a custom adjustment utility 0 1 0 99 Languages Czech Danish Dutch English Finnish French German Greek Hungarian Italian Japanese Korean Norwegian Polish Por tuguese Russian simplified Chinese...

Страница 31: ...2 0 High Speed Bluetooth BLE Bluetooth Low Energy 10 13 Rechargeable Battery Specifications Battery type Rechargeable Lithium ion Battery voltage 3 7 V Battery operating time 5 hours scanning medium...

Страница 32: ...e 2 EN 301 489 1 2011 EN 301 489 17 2009 Encapsulation IP 54 IEC 60529 Shock 25 g IEC 60068 2 27 Vibration 2 g IEC 60068 2 6 Drop Designed for 6 56 ft 2 m Safety CE CB EN61010 UL Environmental safety...

Страница 33: ...3 x 2 5 x 3 2 in 210 x 64 x 81 mm Accessory mount UNC 20 10 16 Included Equipment Standard equipment Camera USB C cable printed Quick Start Guide Lanyard Carry Pouch NAS100014 r AA 59807 59807 en US...

Страница 34: ...s are represented as a gray scale value be tween white and black It may take some time to get used to the thermal im agery Having a basic understanding of the differences between thermal and daylight...

Страница 35: ...netic spectrum Even objects that are very cold such as an ice cube emit infrared When an object is not quite hot enough to radiate visible light it will emit most of its energy in the infrared For exa...