FLIR TA72 Скачать руководство пользователя страница 9

FLIR

 

TA72_TA74

 

USER

 

MANUAL

                                                                             

Document

 

Identifier:

 

TA72_TA74

 

en

US_AC

 

9

5.

 

Operation

 

Note:

 

Before

 

operating

 

the

 

device,

 

please

 

read

 

and

 

understand

 

all

 

Warning

 

and

 

Caution

 

statements

 

and

 

follow

 

all

 

instructions

 

and

 

notes.

 

Note

:

 

Models

 

TA72

 

and

 

TA74

 

are

 

not

 

designed

 

for

 

use

 

with

 

VFD

 

(Variable

 

Frequency

 

Drive)

 

equipment,

 

as

 

erroneous

 

readings

 

may

 

result.

 

Using

 

with

 

VFD

 

equipment

 

does

 

not

 

pose

 

a

 

safety

 

hazard

 

to

 

personnel

 

and

 

will

 

not

 

damage

 

equipment.

 

Please

 

contact

 

FLIR

 

for

 

additional

 

information.

 

 

5.1

 

Powering

 

the

 

Meter

 

The

 

meter

 

is

 

powered

 

by

 

two

 

(2)

 

AAA

 

1.5V

 

batteries

 

(located

 

in

 

the

 

compartment

 

on

 

the

 

back

 

of

 

the

 

meter).

 

Press

 

and

 

hold

 

the

 

Power

 

button

 

 

for

 

>

 

2

 

seconds

 

to

 

switch

 

the

 

device

 

ON

 

or

 

OFF.

 

The

 

meter

 

will

 

beep

 

as

 

it

 

switches

 

ON

 

and

 

one

 

of

 

the

 

Range

 

indicator

 

lamps

 

will

 

be

 

lit.

 

Use

 

the

 

Range

 

button

 

to

 

select

 

a

 

range

 

manually.

 

If

 

the

 

meter

 

does

 

not

 

switch

 

ON

 

please

 

check

 

the

 

batteries

 

located

 

in

 

the

 

rear

 

battery

 

compartment.

 

Refer

 

to

 

the

 

battery

 

replacement

 

section

 

of

 

this

 

User

 

Guide.

 

5.1.1

 

Auto

 

Power

 

OFF

 

(APO)

 

The

 

meter

 

switches

 

OFF

 

automatically

 

after

 

an

 

approximately

 

10

minute

 

period

 

of

 

inactivity.

 

Several

 

seconds

 

before

 

the

 

meter

 

automatically

 

switches

 

OFF

 

the

 

meter

 

beeps

 

several

 

times

 

to

 

alert

 

the

 

user.

 

To

 

disable

 

the

 

APO

 

feature,

 

press

 

both

 

the

 

RANGE

 

and

 

POWER

 

buttons

 

simultaneously

 

(with

 

the

 

meter

 

OFF).

 

The

 

three

 

range

 

indicator

 

LEDs

 

will

 

flash

 

three

 

times.

 

To

 

re

enable

 

APO,

 

turn

 

the

 

meter

 

OFF

 

then

 

ON.

 

The

 

meter

 

re

enables

 

APO

 

each

 

time

 

the

 

meter

 

is

 

powered

 

OFF.

 

5.2

 

Work

 

Lights

 

With

 

the

 

unit

 

powered

 

up,

 

press

 

the

 

Work

 

Light

 

button

to

 

switch

 

the

 

high

 

power

 

Work

 

Lights

 

ON

 

or

 

OFF.

 

Note

 

that

 

excessive

 

use

 

of

 

the

 

Work

 

Lights

 

will

 

shorten

 

battery

 

life.

 

 

Содержание TA72

Страница 1: ...USER MANUAL FLIR MODEL TA72 and TA74 UNIVERSAL FLEX CURRENT PROBE ACCESSORIES...

Страница 2: ...4 3 INTRODUCTION 6 3 1 Key Features 6 4 DESCRIPTIONS 7 4 1 Meter Description 7 4 2 Control buttons and Indicators 8 5 OPERATION 9 5 1 Powering the Meter 9 5 2 Work Lights 9 5 3 AC Current Measurements...

Страница 3: ...identification only and are the property of their respective owners 1 2 Quality Assurance The Quality Management System under which these products are developed and manufactured has been certified in...

Страница 4: ...y the manufacturer the protection provided by the equipment may be impaired Always use proper terminals switch position and range for measurements To reduce the risk of fire or electric shock do not e...

Страница 5: ...CATEGORY OVERVOLTAGE CATEGORY I Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which measures are taken to limit the transient over voltages to an appropriate low level...

Страница 6: ...erwise both meters are the same These devices are professional CAT IV 600V CAT III 1000V instruments with high power Work Lights This meter is shipped fully tested and calibrated and with proper use w...

Страница 7: ...1 Meter Description 1 Flexible Current Clamp Coil 2 Work Lights 3 Coil tip inserts into lock mechanism 4 Clamp lock mechanism 5 Range indicators 6 RANGE select button 7 Power and Work Lights button 8...

Страница 8: ...d Indicators Momentary presses step through the ranges manually When powered press to activate deactivate work lights Press and hold to switch power ON OFF Illuminates when the 30A ranges is selected...

Страница 9: ...and one of the Range indicator lamps will be lit Use the Range button to select a range manually If the meter does not switch ON please check the batteries located in the rear battery compartment Ref...

Страница 10: ...as erroneous readings may result Using with VFD equipment does not pose a safety hazard to personnel and will not damage equipment Please contact FLIR for additional information 1 Switch OFF the Clamp...

Страница 11: ...hands and fingers away from the clamp coil while testing 9 Read the current value in the DMM display Refer to Sections 5 3 1 to 5 3 3 for tips on determining the magnitude of current measured by the T...

Страница 12: ...ading with DMM in ACV mode 5 3 3 Measurement Examples Example 1 30A Current Measurement With the DMM set to the AC voltage mode Clamp set to the 30A range the clamp output will be 3000mV 3 0 VAC DMM w...

Страница 13: ...er OFF before opening the battery compartment 1 Remove the battery compartment Phillips head screw from the back of the meter 2 Remove the battery compartment cover 3 Replace the 2 AAA 1 5V batteries...

Страница 14: ...F 45 C Storage Temperature 4 140 F 20 60 C without batteries Storage Humidity 80 RH maximum Temperature Coefficient 0 2 x specified accuracy C 64 5 F 18 C 82 4 F 28 C Altitude Maximum operating altit...

Страница 15: ...80 Accuracy is specified for a period of one year after calibration Max Output Voltage 4 5V peak Output Noise 5mV for each range Position Error of Clamp Accuracy and position error assumes centralize...

Страница 16: ...ts that qualify for coverage under FLIR s Limited Lifetime Warranty are CM7x CM8x DMxx MR7x TA7x VP5x not including accessories which may have their own warranty 3 WARRANTY PERIODS For purposes of the...

Страница 17: ...packaging the Product for shipment to FLIR and for all packaging and shipping costs FLIR will pay for returning to Purchaser any Product that FLIR repairs or replaces under warranty FLIR reserves the...

Страница 18: ...Customer Support Technical Support Website http support flir com Technical Support Email TMSupport flir com Service and Repair Email Repair flir com Customer Support Telephone 1 855 499 3662 option 3...

Отзывы: