FLIR SR-100A Скачать руководство пользователя страница 2

427-0042-00-10 Revision 130                       Copyright © 2011 FLIR Systems, Inc.  

FLIR Systems Inc. 

70 Castilian Dr. 

Goleta, CA 93117-3027 

888.747.FLIR (888.747.3547) 

Intl.: +1.805.964.9797  

FAX 805 685-2711 

www.flir.com 

 

 

Document Number: 

427-0042-00-10 

 

Revision Date 

Notes 

100 03/27/2010 

Initial 

release 

110 

04/22/2010 

Minor modifications to cover and headers 

120 

07/30/2010 

Added other camera models (SR-1XX and SR-3XX) 

130 

04/06/2011 

Added FCC Regulatory Information, added SR-6xx cameras 

 

 

 

 

EXPORT RESTRICTIONS 

This document is controlled to FLIR Technology Level 1. The information contained in this document pertains to a 
dual use product controlled for export by the Export Administration Regulations (EAR). FLIR trade secrets contained 
herein are subject to disclosure restrictions as a matter of law. Diversion contrary to US law is prohibited. US 
Department of Commerce authorization is not required prior to export or transfer to foreign persons or parties unless 
otherwise prohibited. 

 

PROPRIETARY 

The data in this publication shall not be disclosed without permission and shall not be duplicated, used, or disclosed 
in whole or in part except to the extent provided in any contract of which this document is made a part. This restriction 
does not limit the customer’s right to use information contained in this document if it is obtainable from another source 
without restriction. The data subject to this restriction are contained in all sheets of this document and related 
drawings and document specifications herein. FLIR reserves the right to make changes to its products or 
specifications at any time, without notice, in order to improve design or performance and to supply the best possible 
product. 

 

COPYRIGHT 

Copyright © FLIR Systems, Inc. All rights reserved. This publication, or any parts thereof, may not be reproduced in 
any form without the express written permission of FLIR Systems, Inc. 
 

FEDERAL COMMUNICATIONS COMMISSION REGULATORY INFORMATION 

Modification of this device without the express authorization of FLIR Commercial Systems, Inc., may void the user’s 
authority under the FCC Rules to operate this device. 
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to 
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference 
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate 
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful 
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful 
interference in which case the user will be required to correct the interference at his own expense. 
Shielded cables must be used to connect this device to other devices.   

 
Pelco is a registered trademark of Pelco.  Windows is a registered trademark of Microsoft Corporation.

Содержание SR-100A

Страница 1: ...a an nd d O Op pe er ra at ti io on n M Ma an nu ua al l FLIR Systems Inc 70 Castilian Drive Goleta CA 93117 Phone 888 747 FLIR 888 747 3547 International 1 805 964 9797 http www flir com Camera Model...

Страница 2: ...a subject to this restriction are contained in all sheets of this document and related drawings and document specifications herein FLIR reserves the right to make changes to its products or specificat...

Страница 3: ...ations 11 3 5 Sealed Cable Glands 12 3 6 Analog Video Output 13 3 7 Camera Mounting 13 4 INSTALLATION 14 4 1 Open Camera Enclosure 14 4 2 DIP Switch Settings 15 4 3 Camera Installation 16 5 OPERATING...

Страница 4: ...ure 8 Figure 3 1 Rear view of SR Series camera 9 Figure 3 2 Earth Ground Connection 10 Figure 3 3 Serial Communications Options 11 Figure 4 1 Front view of SR Series camera 14 Figure 4 2 Serial Commun...

Страница 5: ...aws that vary from country to country Check the laws in your local region before using this product for surveillance purposes Support If you have questions that are not covered in this manual or need...

Страница 6: ...g the thermal image on the right provides clear details The SR Series camera is designed for simple intuitive installation and operation Each model is based on the widely deployed uncooled microbolome...

Страница 7: ...he FLIR web site http www flir com cvs cores resources Figure 2 2 White Hot palette on left Black Hot palette on right 2 2 SR Series Camera Models The cameras are available with a choice of lenses for...

Страница 8: ...a lens heater to provide sharp imagery in all temperature and weather conditions ensuring a clear lens and high quality infrared video even in extremely cold environments Figure 2 3 SR 309 Camera wit...

Страница 9: ...Series camera It is necessary to remove the rear of the enclosure in order to access the electrical connections The SR Series provides electrical contacts in the form of screw terminal jacks allowing...

Страница 10: ...inals for receiving tinned leads for input power The power cable should be twisted pair or triple with an overall shield or conduit connected to the enclosure rear panel ground lug as described in the...

Страница 11: ...a is configured for RS 232 protocol then it may be directly attached to a PC or laptop running the FLIR Camera Controller graphical user interface GUI software which is included with the camera or dow...

Страница 12: ...ble should be inserted through the cable gland on the right Leave the glands loosened until the cable installation has been completed Inspect and install gland fittings with suitable leak sealant and...

Страница 13: ...systems camera signals must travel from the camera to the monitor Proper termination of cables is essential to a system s reliable performance The end point of any video cable run must be terminated i...

Страница 14: ...ies cameras come pre configured for RS 232 communication from the factory and the installer may change the option via a DIP switch The switch would only need to be accessed if changing from the defaul...

Страница 15: ...0 ohm termination resistor set to On for RS 422 Removes termination resistor set to Off for RS 232 communications 2 Enables RS 232 communication Enables RS 422 communication Note Daisy chaining of cam...

Страница 16: ...ads attach to the detachable connector according to Table 1 Power and Serial Pin Designations Note the pin numbers are not designated on the connector Connector Pin Used for Power or Serial Communicat...

Страница 17: ...ferred RS 232 or RS 422 configuration 3 Make sure that the O rings supplied on the front and rear covers of the camera enclosure are free of dirt and debris before reassembly The O rings are lubricate...

Страница 18: ...Earth Ground Lug on the inside of the rear of the enclosure refer to Figure 3 2 Earth Ground Connection 6 Insert the enclosure sled and rear plate into the enclosure body Press the two components tog...

Страница 19: ...setting sun in the backlit image on the left makes it difficult to discern any objects of interest the thermal image on the right is not affected by the bright sun and therefore provides detail and c...

Страница 20: ...with familiar objects will be easy to interpret with some experience The camera automatically optimizes the image to provide you with the best contrast in most conditions FLIR Systems Inc offers a co...

Страница 21: ...rface 6 1 Temperature The SR Series camera has an operating temperature range of 40 to 55 C Choose an installation location so that the camera is not subject to temperature extremes that exceed this r...

Страница 22: ...on among others and must be carefully matched to the specific application Moreover the transmission characteristics of the cable will be influenced by the physical environment through which the cable...

Страница 23: ...scene during this time will be quite noticeable and cause the AGC to produce a high contrast image Eastern or Western Exposure Some users will choose to mount the camera pointing directly east or west...

Страница 24: ...pitch SR 1xx SR3xx 25 m SR 6xx 17 m Input power range 14V to 32VDC Voltages as measured at the input to the 18V to 27VAC electrical interface board Fuse 4 Amp fast blow mini blade fuse Ex Bussman BK...

Страница 25: ...24 VAC SR 618 313 at 24 VAC SR 309 612 at 24 VAC SR 606 304 at 24 VAC DC Input Voltage 14 to 32 VDC Voltage as measured at the input to the electrical interface board Nominal Peak Current TRMS 100 410...

Страница 26: ...1 Camera Side View Figure 8 2 Camera Rear View Dimension All cameras except SR 304 SR 606 SR 304 SR 606 Length 10 5 26 7 15 38 14 Width 5 0 12 7 5 0 12 7 Height 5 7 14 4 5 68 14 4 Weight 4 6 lb 2 1 k...

Страница 27: ...Enclosure Product Specification NTSC EIA 170 PAL CCIR 624 MIL STD 810E Environmental Testing MIL STD 188 124B Grounding Bonding and Shielding IEC 60529 Degrees of protection provided by enclosures IP...

Страница 28: ...ems Inc 28 Support If you have questions that are not covered in this manual or need more information contact your local FLIR service representative or 1 877 773 3547 inside the US In the US you can r...

Отзывы: