CP-6408-21-I QIG Rev 110
June 2020
This document does not contain any export-controlled information.
2. Prepare to Install the Camera
2.1 Install FLIR Discovery Network Assistant
Download the FLIR Discovery Network Assistant (DNA) tool to a computer on the
same VLAN to which you will connect the camera, and then unzip the file. The DNA
tool does not require a license to use and is a free download from
Products > Security > Visible Security Cameras > Quasar 4K IR PTZ Camera
2.2 Perform a Bench Test (Optional)
You can test the camera or configure it for networking before mounting it. Follow
the instructions in
, and
then continue with
2.3 Select a Location
Select a suitable location to mount the camera.
For advice on positioning and orienting the camera, see the camera's installation
and user guide.
Verify that the operating temperature range is between -40°C ~ 50°C (-40° ~ 122°
F), 10-90% relative humidity (non-condensing).
For the list of mounting accessories available for the camera, see the
FLIR
Security Cameras - Accessory Guide
.
3. Install the Camera
3.1 Fit Mounting Hardware
If required, install the mounting hardware for the camera according to the
instructions in the camera's installation and user guide.
3.2 Route Network and Power
Properly install the power and network cabling in the mounting hardware so that it is
accessible when the camera is mounted.
Power:
Universal Power over Ethernet (PoE) 60W 4 pair forced mode, 12 VDC,
or 24 VAC.
Ethernet:
Cat5e or Cat6 cable. Ethernet is required for streaming video and
configuring the camera.
3.3 Mount the Camera
Mount the camera according to the instructions in the camera's installation and user
guide.