![FLIR PTZ-35 MS Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/flir/ptz-35-ms/ptz-35-ms_installation-and-operation-manual_2305796021.webp)
427-0016-00-10 Revision 120
Copyright © 2008 FLIR Systems, Inc. 21
Integrated Interface Cable Connector
The PTZ-35 MS / PTZ-50 MS uses an electrical-
mechanical engagement system that requires only one integrated cable to interface with the sensor.
The interface cable is 12.5 meters (± 0.5) long and is terminated with a MIL-C-26482 Series 1
Connector (Male). The table below describes the specifications:
MIL-C-26482 Series 1
Shell Size
18
Insert Arrangement
32
Finish Olive
drab
chromate over
cadmium
Contacts Pines
Shell Style
Cable plug
Insert Position
Keyring
Figure 16: PTZ-35 MS / PTZ-50 MS Interface Cable Connector
Function Pin
Signal Name Function Pin
Signal Name
Power
j
VDC1
Comms
N
Tx RS-232 (COM1)
b
VDC1 RTN
M
Rx RS-232 (COM1)
f
VDC2
c
GND RS-232 (COM1)
h
VDC2 RTN
A
Tx (-)RS-422 (COM3)
g
VDC3
T
Rx (-)RS-422 (COM3)
Z
VDC3 RTN
U
Tx (+)RS-422 (COM3)
S
Rx
(+)RS-422
(COM3)
Video
K
Video
1
L
Video 1 Shield
H
Video
2
J
Video 2 Shield
Chassis connector front view (Female
)
Interface cable connector front view (Male)