Copyright 2017, FLIR Commercial Systems, Inc.
Chapter 3: Quick Start
11
3. Connect the AC plug on the power supply into a power strip with a switch, and then connect the DC
connector to either the breakout cable or customer-supplied cable.
4. Establish Ethernet or serial wiring to the PTU as appropriate for your needs.
-
Please see
“Ethernet Connection” on page 11
for Ethernet/Web instructions.
-
Please see
“Serial Connection” on page 13
for serial/ASCII instructions.
5. Power on and test the PTU.
6. Attach a payload to the top or side brackets.
3.4 - Ethernet Connection
The PTU contains a Web-based interface that allows you to test and program various functions. This
interface is accessible via the Ethernet connection on the breakout cable.
To connect, power on, and test the PTU using the Ethernet connection and Web interface:
1. Connect one end of an RJ-45 Ethernet cable to the PTU, and then connect the other end of the cable
to the host computer, either directly or through a router/hub.
2. Connect a power source to the PTU, making sure to incorporate a readily accessible power
disconnect (such as a power strip) to allow safe power removal from the system. See
3. Ensure that the PTU is clear to move in both axes (pan and tilt) without hitting any obstructions
before applying power.
4. Power on the PTU. When the PTU-5 is powered up, it goes through a short reset in both axes. The
amount of motion on reset will vary at different areas of the axis, but generally it will move no more
than 12 degrees in either direction.
CAUTION: THE PTU-5 DOES NOT SUPPORT SIMULTANEOUS MOUNTING OF PAYLOADS
ON BOTH THE TOP AND SIDE BRACKETS.
Note: You may use simultaneous Ethernet and serial connections.
CAUTION: REMOVING POWER BY PULLING THE PLUG CAN DAMAGE THE PTU.
WARNING: HITTING AN OBSTACLE WHILE THE PTU IS IN MOTION COULD CAUSE A
MOUNTING OR OTHER STRUCTURAL FAILURE THAT COULD RESULT IN INJURY OR
DEATH.
Содержание PTU-5
Страница 1: ...High Performance Pan Tilt Unit User Manual MODEL PTU 5 VERSION 1 00 REVISION DATE March 31 2017...
Страница 10: ...PTU 5 User Manual Copyright 2017 FLIR Commercial Systems Inc 6 This page intentionally left blank...
Страница 28: ...PTU 5 User Manual Copyright 2017 FLIR Commercial Systems Inc 24 This page intentionally left blank...
Страница 34: ...PTU 5 User Manual Copyright 2017 FLIR Commercial Systems Inc 30 This page intentionally left blank...
Страница 40: ...PTU 5 User Manual Copyright 2017 FLIR Commercial Systems Inc A 6 This page intentionally left blank...
Страница 44: ...PTU 5 User Manual Copyright 2017 FLIR Commercial Systems Inc B 4 This page intentionally left blank...