Chapter 1: Introduction

5

1.8 - Related Documentation

The following additional documentation is available for your PTU:

PTU Configuration Guide:

 options and accessories ordering guide for your specific PTU model

PTU Product Datasheet:

 

product specifications for your specific PTU model

Pan-Tilt E Series Command Reference Manual: 

command instructions

1.9 - Additional Resources

FLIR Systems, Inc. also maintains a technical support Web site with additional resources for customers in 
the 

Support

 section at 

www.FLIR.com/MCS

. Resources include electronic copies of user manuals, 

firmware downloads, 3D CAD models, technical notes, and other information.

1.10 - Technical Support

FLIR Systems, Inc. provides a range of technical support options:

Email:

 

[email protected]

Web: 

www.FLIR.com/MCS

Phone: 

(888)747-3547

The preferred method of contacting Technical Support is via email, which helps ensure proper 
dispatching and tracking to address your questions promptly.

When contacting Technical Support, please provide the following information:

PTU model and configuration

Payload (Please include photos, if possible.)

Parameter settings

Description of issue/symptoms

Содержание PTU-5

Страница 1: ...High Performance Pan Tilt Unit User Manual MODEL PTU 5 VERSION 1 00 REVISION DATE March 31 2017...

Страница 2: ...may be reproduced stored in a retrieval system or transcribed in any form or by any means including but not limited to electronic mechanical photocopying recording or otherwise without the prior writ...

Страница 3: ...rnings and Cautions 7 3 Quick Start 9 3 1 System Overview 9 3 2 Installation Components 10 3 3 Basic Setup 10 3 4 Ethernet Connection 11 3 5 Serial Connection 13 4 Installation Setup 15 4 1 Mounting t...

Страница 4: ...29 F Electrical Specifications 1 6 1 26 Pin Base Connector 2 6 2 12 Pin Payload Connector 3 6 3 26 Pin Breakout Cable 4 6 4 PTU 5 Internal Wiring 5 G Mechanical Drawings 1 H Networking 1 8 1 Ethernet...

Страница 5: ...ormance Turn on and begin slewing to track moving targets in seconds 5 seconds startup time Reduced calibration movement PTU 5 does not need to home to 0 0 Programmable ranges of motion Output shaft e...

Страница 6: ...an 180 tilt side mount only Axis Speeds 100 second continuous Slip Ring Channels 11 including power video serial and Ethernet Connectors HD26 base M12 payload Phoenix Contact 1411979 mates to 1411987...

Страница 7: ...several formatting conventions to present information of special importance Lists of items points to consider or procedures that do not need to be performed in a specific order appear in bullet forma...

Страница 8: ...TU 5 unit AC DC power supply with cord PT PS 30V NA Payload mounting brackets top or side Mating connector for payload Phoenix Contact 1411987 Breakout cable 308 0278 XX 00 where XX is the cable lengt...

Страница 9: ...resources for customers in the Support section at www FLIR com MCS Resources include electronic copies of user manuals firmware downloads 3D CAD models technical notes and other information 1 10 Techn...

Страница 10: ...PTU 5 User Manual Copyright 2017 FLIR Commercial Systems Inc 6 This page intentionally left blank...

Страница 11: ...t the PTU and payload remain unobstructed at all times All mounting methods and materials must be capable of supporting at least four times the combined weight of the PTU mounted payloads and cabling...

Страница 12: ...8 Keep all persons and objects well away from the PTU panning and tilting radius with payload installed Do not touch or otherwise handle the PTU while in motion or if there is a possibility of motion...

Страница 13: ...serial connection The PTU also allows payload pass through wiring that internally routes payload signals payload power video etc from a single stationary connector in the PTU base to a single payload...

Страница 14: ...3 Basic Setup To perform a basic PTU setup and installation 1 Mount the PTU securely to a lab bench tripod or other stable platform Verify that there is enough clearance around the unit See Mounting...

Страница 15: ...thernet cable to the PTU and then connect the other end of the cable to the host computer either directly or through a router hub 2 Connect a power source to the PTU making sure to incorporate a readi...

Страница 16: ...iate IP address such as http 192 168 1 101 A web page appears when you are connected to the selected PTU The PTU Web interface allows you to configure the network interface configure various parameter...

Страница 17: ...onnect the RS485 connector from the breakout cable into the adapter Provide power to the converter through the included power supply Alternatively you can connect the USB to RS 485 cable PTU CONV USB...

Страница 18: ...m The following command sequence will familiarize you with basic PTU D48E operation pp2500 tp 900 PS1900 pp0 This sequence sets the pan axis to position 2500 sets the tilt axis to position 900 sets th...

Страница 19: ...dditional forces exerted on the system such as wind G forces etc A good rule of thumb is that the mount must be capable of supporting at least four times the combined weight of the PTU and payload For...

Страница 20: ...uts and wiring diagrams for the available PTU wiring configurations if needed you may use this information to make custom cables to suit your specific installation requirements Please refer to Quick S...

Страница 21: ...Regulatory Warranty Information on page E 1 All PTU wiring configurations provide a shield pin at both the base and the payload as described in Electrical Specifications on page A 1 This shield is als...

Страница 22: ...ectly to the host computer If needed you may use a coupling to extend the Ethernet connection on the breakout cable Connect power on and test the PTU using the Ethernet connection and Web interface as...

Страница 23: ...unit Please see the Pan Tilt E Series Command Reference Manual for more information about the Web interface 4 7 2 Terminal Interface To test the PTU using the serial interface 1 Configure the RS 232...

Страница 24: ...is being mounted in an outdoor location use corrosion resistant hardware such as stainless steel Apply thread locking compound to all screws such as Loctite 242 which is suitable for applications tha...

Страница 25: ...that the payload will clear the PTU housing and all surrounding objects throughout the entire range of motion Your PTU is rated for the loads specified in PTU 5 Features on page 2 however load distri...

Страница 26: ...and refer to Heavy Payload Operation on page 28 and Battery Powered Operation on page 29 This does not damage the PTU but does indicate that the payload is not mounted and or the PTU is not configure...

Страница 27: ...ediately if this occurs and refer to Heavy Payload Operation on page 28 and Battery Powered Operation on page 29 5 If the PTU passes the above pan and tilt axis load handling tests you are ready to be...

Страница 28: ...PTU 5 User Manual Copyright 2017 FLIR Commercial Systems Inc 24 This page intentionally left blank...

Страница 29: ...e limited in the following ways Factory Factory limits are smaller than hard limits to prevent physical damage to the PTU and or payload User User limits are programmable limits that are smaller than...

Страница 30: ...t drive the unit through a gear reduction system The internal controller allows stepper motor control in manual and 1 8 or automatic step modes The following table lists the pan and tilt axis resoluti...

Страница 31: ...centers of rotation as possible Doing this will reduce the torque required to move the payload and allow a higher top speed Balancing the load such as by using a counterweight or splitting the payloa...

Страница 32: ...ram it for higher power operations The speed and acceleration of a mechanical system depend on the inertial properties of the payload The ability of the PTU to successfully move the payload without lo...

Страница 33: ...must conserve as much power as possible The PTU includes commands that control pan tilt motor power consumption both while moving and when stopped For example you can use the PHO and THO commands to...

Страница 34: ...PTU 5 User Manual Copyright 2017 FLIR Commercial Systems Inc 30 This page intentionally left blank...

Страница 35: ...a mechanical overview In general TX lines carry data from the PTU 5 RX lines carry data to the PTU 5 CAUTION DO NOT EXCEED MAXIMUM RATED PASS THROUGH AMPERAGES FUSE PAYLOADS AT RATED TRIP VALUES THE P...

Страница 36: ..._GROUND 6 PAYLOAD SIGNAL 6 7 PAYLOAD SIGNAL 9 8 PAYLOAD SIGNAL 2 9 CHASSIS GROUND 10 PTU POWER SUPPLY 11 PTU_PHY_TXP 12 PTU_PHY_RXN 13 PTU_RS485_RX 14 PAYLOAD SIGNAL 7 15 PAYLOAD SIGNAL 10 16 PAYLOAD...

Страница 37: ...2 pin payload connector part number 1411979 mates to part number 1411987 pin assignments PIN ASSIGNMENT 1 PAYLOAD SIGNAL 1 2 PAYLOAD SIGNAL 2 3 NOT USED 4 PAYLOAD SIGNAL 3 5 PAYLOAD SIGNAL 4 6 PAYLOAD...

Страница 38: ...TURN PIN_19 KHAKI PIN_2 PURPLE 1 8 PTU_PHY_TXP WHITE ORANGE PTU_PHY_TXN ORANGE PTU_PHY_RXP WHITE GREEN PTU_PHY_RXN GREEN PTU_RS485_GND BLACK PTU_RS485_TX BROWN PTU_RS485_TX RED PTU_RS485_RX WHITE PTU_...

Страница 39: ...ETURN PIN_19 KHAKI PIN_2 PURPLE PTU_PHY_TXP WHITE ORANGE PTU_PHY_TXN ORANGE PTU_PHY_RXP WHITE GREEN PTU_PHY_RXN GREEN PTU_RS485_GND BLACK PTU_RS485_TX BROWN PTU_RS485_TX RED PTU_RS485_RX WHITE PTU_RS4...

Страница 40: ...PTU 5 User Manual Copyright 2017 FLIR Commercial Systems Inc A 6 This page intentionally left blank...

Страница 41: ...ms Inc B 1 B Mechanical Drawings The drawings in this Appendix describes the payload mounting patterns for the different brackets and displays the PTU dimensions 6 18 157 0 2 56 65 0 6 03 153 2 3 76 9...

Страница 42: ...PTU 5 User Manual Copyright 2017 FLIR Commercial Systems Inc B 2 6 69 169 8 3 58 90 9 19 4 7 2 92 74 2 TYP 39 10 0 1 4 20 UNC THRU 94 24 0 08 R2 0 2 37 60 2 73 18 5 TOP MOUNT BRACKET CONFIGURATION...

Страница 43: ...ht 2017 FLIR Commercial Systems Inc Appendix B Mechanical Drawings B 3 2 35 59 6 2 29 58 2 19 4 7 1 42 36 0 1 37 34 7 1 57 40 0 39 10 0 TYP 1 18 30 0 08 R2 0 1 4 20 UNC THRU SIDE MOUNT BRACKET CONFIGU...

Страница 44: ...PTU 5 User Manual Copyright 2017 FLIR Commercial Systems Inc B 4 This page intentionally left blank...

Страница 45: ...connect to multiple units at once Please see Ethernet Connection on page 11 for more information about connecting to a PTU using the Web interface C 2 Serial You may connect up to 127 PTUs to a singl...

Страница 46: ...C 1 PTU Network Configuration When making your own data cables FLIR Systems Inc recommends using a good quality twisted pair cable with about 100 impedance which provides good noise immunity for RS 48...

Страница 47: ...sic ASCII query syntax is command delimiter where command is the actual command such as PP for pan position delimiter is a character used to denote the end of a query Valid delimiter characters can be...

Страница 48: ...m tilt position LD Disable limits TX Maximum tilt position LU User limits CMD DESCRIPTION CMD DESCRIPTION PP Pan position PR Pan resolution TP Tilt position TR Tilt resolution PO Pan offset TO Tilt of...

Страница 49: ...ayload attached contact FLIR Technical Support D 2 Power The PTU 5 reset movements are different than other PTU models This is normal behavior the PTO does not return to 0 0 D 3 Networking Unable to d...

Страница 50: ...dapter If you are using a laptop make sure that it is plugged in RS 485 will not work if the PTU and host computer grounds are too far apart D 4 Technical Support FLIR Systems Inc provides a range of...

Страница 51: ...he user will be required to correct the interference at his her own expense FLIR PTUs using a cable length of 7 or less and using the PT PS INT30V power supply have been tested to comply with FCC Clas...

Страница 52: ...al information or to see a demonstration of these revolutionary thermal night vision systems contact a FLIR representative today You can also visit www FLIR com to watch prod uct videos and see how th...

Страница 53: ...han FLIR or FLIR s authorized designee and b Goods that are defective due either to normal wear and tear or Buyer s failure to properly store install operate or maintain the Goods The Remedy is FLIR s...

Страница 54: ...PTU 5 User Manual v 1 00 03 31 2017 6769 Hollister Avenue Goleta CA 93117 p 805 964 9797 f 805 690 5933 www FLIR com MCS...