background image

Document

 

Identifier:

 

MR09

mul_AA

   

03/16

 

Copyright

 

©

 

2016

 

FLIR

 

Systems,

 

Inc.

  

www.flir.com

    

For

 

additional

 

languages

 

visit

 

www.flir.com/test

 

 

1

2

3

4

5

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

USER

 

GUIDE

  

MR09

 

 

BASEBOARD

 

PROBE

 

Introduction

 

Thank

 

you

 

for

 

selecting

 

the

 

FLIR

 

Moisture

 

Meter

 

Baseboard

 

Probe

 

Model

 

MR09.

 

When

 

connected

 

to

 

a

 

FLIR

 

Moisture

 

Meter,

 

the

 

MR09

 

allows

 

the

 

user

 

to

 

take

 

relative

 

moisture

 

measurements

 

behind

 

trim

 

pieces,

 

baseboards,

 

crown

 

molding,

 

and

 

masonry;

 

under

 

tile,

 

inside

 

walls/ceilings,

 

and

 

other

 

such

 

places

 

where

 

the

 

sensor

 

blades

 

can

 

be

 

inserted.

 

The

 

blades

 

are

 

designed

 

to

 

‘flex’

 

into

 

the

 

measurement

 

cavity

 

eliminating

 

the

 

need

 

to

 

remove

 

the

 

obstacle

 

that

 

would

 

otherwise

 

prevent

 

a

 

standard

 

pin

 

or

 

pinless

 

measurement.

 

This

 

probe

 

is

 

designed

 

to

 

operate

 

with

 

FLIR

 

Moisture

 

Meters.

 

Safety

 

Instructions

 

 

This

 

device

 

should

 

be

 

used

 

only

 

for

 

purposes

 

outlined

 

in

 

this

 

guide.

 

Misuse

 

may

 

cause

 

damage

 

to

 

the

 

MR09

 

and/or

 

external

 

devices,

 

and

 

can

 

cause

 

personal

 

injury.

 

 

Keep

 

the

 

MR09

 

packed

 

when

 

not

 

in

 

use.

 

Note

 

that

 

the

 

MR09

 

can

 

be

 

stored

 

in

 

the

 

MR07

 

or

 

MR08

 

carry

 

case

 

for

 

convenience.

 

 

Do

 

not

 

allow

 

children

 

to

 

handle

 

the

 

MR09.

 

Description

 

1.

 

Conversion plate 9.5mm (3/8”) mounting hole

 

2.

 

Handle

 

grip

 

3.

 

Sensor

 

blades

 

4.

 

BNC

 

cable

 

jack

 

5.

 

BNC

 

to

 

RJ45

 

connector

 

cable

 

Operating

 

Instructions

 

1.

 

Carefully

 

remove

 

the

 

MR09

 

from

 

its

 

packaging.

 

2.

 

Connect

 

the

 

probe

 

to

 

the

 

moisture

 

meter

 

using

 

the

 

supplied

 

BNC/RJ45

 

cable

 

(BNC

 

connection

 

on

 

probe

 

and

 

RJ45

 

connection

 

on

 

FLIR

 

moisture

 

meters).

 

3.

 

Operate

 

the

 

Moisture

 

Meter

 

as

 

described

 

in

 

its

 

User

 

Guide.

 

4.

 

Hold

 

the

 

MR09

 

handle

 

grip

 

firmly

 

when

 

maneauvering

 

the

 

blades

 

in

 

the

 

area

 

to

 

test.

 

Specifications

 

Blade

 

material:

 

400

series

 

stainless

 

steel;

 

thickness:

 

1mm

 

(0.04

 

in.)

 

Measurement

 

type:

 

Resistive

 

moisture

 

measurements

 

for

 

reference

 

only

 

Penetration

 

depth:

 

15cm

 

(6

 

in.)

 

maximum

 

Mounting

 

hole:

 

9.5mm

 

(3/8

 

in.)

 

threaded

 

Cable

 

length:

 

2.45cm

 

(8

 

ft.)

 

Dimensions:

 

34

 

x

 

10

 

x

 

6cm

 

(13.4

 

x

 

4.0

 

x

 

2.4

 

in.)

 

Weight:

 

494g

 

(1.2

 

lbs.)

 

Warranty

 

FLIR

 

Systems,

 

Inc.

 

warrants

 

this

 

device

 

to

 

be

 

free

 

of

 

defects

 

in

 

parts

 

and

 

workmanship

 

for

 

2

 

(

two)

 

years

 

from

 

date

 

of

 

shipment

 

providing:

 

 

Device

 

is

 

purchased

 

from

 

FLIR

 

Commercial

 

Systems

 

or

 

an

 

Authorized

 

reseller

 

 

Device

 

is

 

registered

 

online

 

at

 

www.flir.com/test/warranty

 

within

 

60

 

days

 

of

 

shipment

 

 

FLIR

 

is

 

notified

 

within

 

30

 

days

 

of

 

a

 

defect

 

being

 

found

 

 

Contact

 

FLIR

 

Return

 

Material

 

Authorization

 

before

 

returning

 

the

 

product

 

for

 

a

 

Return

 

Authorization

 

number

 

 

The

 

sender

 

is

 

responsible

 

for

 

shipping

 

charges,

 

freight,

 

insurance

 

and

 

proper

 

packaging

 

to

 

prevent

 

damage

 

in

 

transit.

  

This

 

warranty

 

does

 

not

 

apply

 

to

 

defects

 

resulting

 

from

 

action

 

of

 

the

 

user

 

such

 

as

 

misuse,

 

improper

 

wiring,

 

operation

 

outside

 

of

 

specification,

 

improper

 

maintenance

 

or

 

repair,

 

or

 

unauthorized

 

modification.

  

FLIR

 

SYSTEMS,

 

INC.

 

SPECIFICALLY

 

DISCLAIMS

 

ANY

 

IMPLIED

 

WARRANTIES

 

OR

 

MERCHANTABILITY

 

OR

 

FITNESS

 

FOR

 

A

 

SPECIFIC

 

PURPOSE

 

AND

 

WILL

 

NOT

 

BE

 

LIABLE

 

FOR

 

ANY

 

DIRECT,

 

INDIRECT,

 

INCIDENTAL

 

OR

 

CONSEQUENTIAL

 

DAMAGES.

 

FLIR’s

 

total

 

liability

 

is

 

limited

 

to

 

repair

 

or

 

replacement

 

of

 

the

 

product.

 

The

 

warranty

 

set

 

forth

 

above

 

is

 

inclusive

 

and

 

no

 

other

 

warranty,

 

whether

 

written

 

or

 

oral,

 

is

 

expressed

 

or

 

implied.

 

To

 

read

 

the

 

entire

 

2

 

(two)

 

year

 

warranty

 

agreement

 

please

 

visit

 

www.flir.com/test/warranty

 

For

 

Technical

 

Support:

 

email

 

[email protected]

 

or

 

call

 

+1

 

855

499

3662

 

(option

 

3)

 

 

Отзывы: