Figure 42 - Illustration of Lepton Detector Time Constant
In addition to integrating signal current, the ROIC also digitizes and multiplexes the signal from each detector into
a serial stream. And the Lepton ROIC digitizes data from an on-chip temperature sensor as well as a thermistor
attached to the camera housing. An anti-reflection (AR) coated window is bonded above the sensor array via a
wafer-level packaging (WLP) process, encapsulating the array in a vacuum. The purpose of the vacuum is to
provide high thermal resistance between the microbolometer elements and the ROIC substrate, allowing for
maximum temperature change in response to incident radiation.