FLIR
LEPTON® Engineering Datasheet
The information contained herein does not contain technology as defined by the EAR, 15 CFR 772, is publicly available,
and therefore, not subject to EAR. NSR (6/14/2018).
Information on this page is subject to change without notice.
Lepton Engineering Datasheet, Document Number: 500-0659-00-09 Rev: 203
32
the camera's operating temperature range. The resulting output for three different scene temperatures is
illustrated hypothetically in
(note that the figure is for illustration purposes and not perfectly
representative).
Figure 11 - Hypothetical Illustration of Camera Output vs. Camera Temperature in Radiometry-
disabled Mode
3.5.4
Radiometric Accuracy
–
Module
Lepton camera module radiometric accuracy in high gain mode is ±5°C @ 25°C against a 35°C blackbody for a
Lepton camera module (using a simple test
board with no significant heat sources) at equilibrium and 1”
blackbody at 25cm, corrected for emissivity, and in a normal room environment. In high gain mode the intra-
scene temperature range is typically -10°C to 140°C.
Lepton camera module radiometric accuracy in low gain mode is ±10°C @ 25°C against a 35°C blackbody for a
Lepton camera module (using a simple test board with no significant heat sources) at equilibrium and 1”
blackbody at 25cm, corrected for emissivity, and in a normal room environment. In low gain mode the intra-
scene temperature range is typically -10°C to 450°C (or 400 °C for Lepton 3.5).
3.5.5
Radiometric Accuracy
–
System Considerations