Maintenance 

WARNING: 

To avoid electrical shock, disconnect the meter from any circuit, remove the 

test leads from the input terminals, and turn OFF the meter before opening the case. Do 
not operate the meter with an open case. 

Cleaning and Storage 

Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or  
solvents. If the meter is not to be used for 60 days or more, remove the battery and store it 
separately. 

Battery Replacement 

1. 

Remove the 2 Phillips head screws that secures the rear battery cover 

2. 

Open the battery compartment 

3. 

Replace the 2 AAA batteries. 

4. 

Secure the battery compartment door 

Calibration and Repair Services 

Extech offers repair and calibration services

 for the products we sell. Extech also 

provides NIST certification for most products. Call the Customer Care Department for 
information on calibration services available for this product. Extech recommends that 
annual calibrations be performed to verify meter performance and accuracy. 

Warranty 

EXTECH INSTRUMENTS CORPORATION (A FLIR COMPANY) warrants this instrument to be 
free of defects in parts and workmanship for one year from date of shipment (a six month limited 
warranty applies to sensors and cables). If it should become necessary to return the instrument for 
service during or beyond the warranty period, contact the Customer Service Department at (781) 
890-7440 ext. 210 for authorization or visit our website www.extech.com for contact information. A 
Return Authorization (RA) number must be issued before any product is returned to Extech. The 
sender is responsible for shipping charges, freight, insurance and proper packaging to prevent 
damage in transit. This warranty does not apply to defects resulting from action of the user such as 
misuse, improper wiring, operation outside of specification, improper maintenance or repair, or 
unauthorized modification. Extech specifically disclaims any implied warranties or merchantability 
or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or 
consequential damages. Extech's total liability is limited to repair or replacement of the product. 
The warranty set forth above is inclusive and no other warranty, whether written or oral, is 
expressed or implied. 

 

 
 

Содержание Extech Instruments MA410

Страница 1: ......

Страница 2: ...his CAUTION symbol indicates a potentially hazardous situation which if not avoided may result damage to the product PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY OVERVOLTAGE CATEGORY I Equipment of O...

Страница 3: ...st leads before replacing the battery or fuses Inspect the condition of the test leads and the meter itself for any damage before operating the meter Repair or replace any damage before use Use great...

Страница 4: ...1 Relative Button 12 Battery compartment rear 13 Positive input jack Display icons Description HOLD Data Hold AUTO Autoranging DC Direct Current AC Alternating Current Low battery REL Relative V Volts...

Страница 5: ...MA410 V2 2 08 08 5...

Страница 6: ...e display 6 Press the Hz button to display Frequency 7 Press the Hz button to display Duty Cycle Resistance Diode Continuity Measurements Note Remove power from the device under test before making res...

Страница 7: ...MA410 V2 2 08 08 7...

Страница 8: ...n the REL mode autoranging is disabled and measurements are limited to the range active when the REL button was pressed Press the REL button to exit the mode Note Relative does not function in Frequen...

Страница 9: ...ENTS CORPORATION A FLIR COMPANY warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment a six month limited warranty applies to sensors and cables If...

Страница 10: ...0 VDC 1V 2 0 2 digits 400 0 0 1 1 0 4 digits 4 000k 0 001k 40 00k 0 01k 400 0k 0 1k 1 5 2 digits 4 000M 0 001M 2 5 3 digits Resistance 40 00M 0 01M 3 5 5 digits 40 00nF 0 01nF 4 0 20 digits 400 0nF 0...

Страница 11: ...2 readings per second nominal Thermocouple sensor Type K thermocouple required Input Impedance 10M VDC and VAC AC bandwidth 50 to 400Hz VAC AC response Average responding Operating Temperature 41 F t...

Страница 12: ...more infor for Extech MA410 Phone 01235 838 555 Email cs airconcern co uk Web www airconcern co uk Air Concern Ltd Building 173 Curie Avenue Harvell Didcot Oxfordshire...

Отзывы: