Infrared inspections of roofs with nonabsorbent insulations, common in many single-
ply systems, are more difficult to diagnose because patterns are more diffuse.
This section includes a few typical infrared images of moisture problems on low-slope
commercial roofs:
Comment
Infrared image
Moisture detection on a roof, recorded during the
evening.
Since the building material affected by moisture
has a higher thermal mass, its temperature decreas-
es slower than surrounding areas.
10554003;a1
Water-damaged roofing components and insula-
tion identified from infrared scan from the under-
side of the built-up roof on a structural concrete
tee deck.
Affected areas are cooler than the surrounding
sound areas, due to conductive and/or thermal
capacitive effect.
10554103;a1
Daytime survey of built-up low-slope commercial
roof.
Affected areas are cooler than the surrounding dry
areas, due to conductive and/or thermal capacitive
effect.
10554203;a1
56
Publ. No. T559382 Rev. a358 – ENGLISH (EN) – June 23, 2009
16 – Introduction to building thermography