Area Equations
CFM (ft
3
/min) = Air Velocity (ft/min) x Area (ft
2
)
CMM (m
3
/min) = Air Velocity (m/sec) x Area (m
2
) x 60
Battery Replacement
Switch the meter OFF and remove the screw that secures the rear battery
compartment. Open the compartment and replace the 9V battery, observing
correct polarity. Re-assemble the meter before use.
LCD Backlight
Short press the backlight button
to switch the backlight ON/OFF.
Data Hold
Short press
H
to access/exit the Data Hold mode. Data Hold freezes the
displayed reading. The
HOLD
icon will appear while in the Data Hold mode.
MAX-MIN-AVG Recording
Short press
MAX|MIN|AVG
to start recording (REC) and to step through
maximum, minimum, and average readings. Long press
MAX|MIN|AVG
to exit.
3-Year Limited Warranty
This product is protected by FLIR’s 3
-Year Limited Warranty. Visit
to read the 3-Year Limited Warranty document.
Register your product at the website to receive a free 1-year warranty
extension.