FLIR DM6x USER MANUAL Document Identifier: DM6x-en-US_AA
28
Diode Tester
RANGE
Accuracy
3.000V
0.9% + 2d
Test Current: 0.3mA typical
Open Circuit Voltage: < 3.2VDC typical
DC Current
RANGE
Accuracy
Burden Voltage
600.0
A, 6000
A
1.0% + 3d
0.1mV/
A
60.00mA, 600.0mA
0.7% + 3d
1.9mV/mA
6.000A, 10.00A
1)
0.04V/A
1)
10A continuous, >10A to 20A for 30 seconds max with 5 minutes cool down interval
AC Current
RANGE
Accuracy
Burden Voltage
50H
Z
~
400H
Z
600.0
A, 6000
A
1.5% + 3d
0.1mV/
A
60.00mA, 600.0mA
1.0% + 3d
1.9mV/mA
6.000A
1)
, 10.00A
2)
0.04V/A
1)
<5d non-zero residue may appear when backlight is on, which will not affect the
specified measuring range and accuracy
2)
10A continuous, >10A to 20A for 30 seconds max with 5 minutes cool down interval
Temperature (DM64/DM66)
RANGE
Accuracy
1) 2)
-40.0
o
C ~ 99.9
o
C
1% + 1
o
C
100
o
C ~ 400
o
C
-40.0
o
F ~ 99.9
o
F
1% + 2
o
F
100
o
F ~ 752
o
F
1)
Accuracies assume meter interior and the ambient air have reached the same
temperature for a correct junction voltage compensation. Allow enough settling time for
a significant change of ambient temperature. It can take up to an hour for changes > 5
o
C
(>9
o
F).
2)
Type-K thermocouple range & accuracy not included