FLIR CM72 Скачать руководство пользователя страница 4

FLIR

 

CM72_CM74

 

USER

 

MANUAL

                                                          

Document

 

Identifier:

 

CM72_CM74

en

US_AA

 

4

1.

 

Disclaimers

 

1.1

 

Copyright

 

©

 

2015,

 

FLIR

 

Systems,

 

Inc.,

 

All

 

rights

 

reserved

 

worldwide.

 

No

 

parts

 

of

 

the

 

software

 

including

 

source

 

code

 

may

 

be

 

reproduced,

 

transmitted,

 

transcribed

 

or

 

translated

 

into

 

any

 

language

 

or

 

computer

 

language

 

in

 

any

 

form

 

or

 

by

 

any

 

means,

 

electronic,

 

magnetic,

 

optical,

 

manual

 

or

 

otherwise,

 

without

 

the

 

prior

 

written

 

permission

 

of

 

FLIR

 

Systems.

 

The

 

documentation

 

must

 

not,

 

in

 

whole

 

or

 

part,

 

be

 

copied,

 

photocopied,

 

reproduced,

 

translated

 

or

 

transmitted

 

to

 

any

 

electronic

 

medium

 

or

 

machine

 

readable

 

form

 

without

 

prior

 

consent,

 

in

 

writing,

 

from

 

FLIR

 

Systems.

 

Names

 

and

 

marks

 

appearing

 

on

 

the

 

products

 

herein

 

are

 

either

 

registered

 

trademarks

 

or

 

trademarks

 

of

 

FLIR

 

Systems

 

and/or

 

its

 

subsidiaries.

 

All

 

other

 

trademarks,

 

trade

 

names

 

or

 

company

 

names

 

referenced

 

herein

 

are

 

used

 

for

 

identification

 

only

 

and

 

are

 

the

 

property

 

of

 

their

 

respective

 

owners.

 

1.2

 

Quality

 

Assurance

 

The

 

Quality

 

Management

 

System

 

under

 

which

 

these

 

products

 

are

 

developed

 

and

 

manufactured

 

has

 

been

 

certified

 

in

 

accordance

 

with

 

the

 

ISO

 

9001

 

standard.

 

FLIR

 

Systems

 

is

 

committed

 

to

 

a

 

policy

 

of

 

continuous

 

development;

 

therefore

 

we

 

reserve

 

the

 

right

 

to

 

make

 

changes

 

and

 

improvements

 

on

 

any

 

of

 

the

 

products

 

without

 

prior

 

notice.

 

1.3

 

Documentation

 

To

 

access

 

the

 

latest

 

manuals

 

and

 

notifications,

 

go

 

to

 

the

 

Download

 

tab

 

at:

 

http://support.flir.com.

 

It

 

only

 

takes

 

a

 

few

 

minutes

 

to

 

register

 

online.

 

In

 

the

 

download

 

area

 

you

 

will

 

also

 

find

 

the

 

latest

 

releases

 

of

 

manuals

 

for

 

our

 

other

 

products,

 

as

 

well

 

as

 

manuals

 

for

 

our

 

historical

 

and

 

obsolete

 

products.

 

1.4

 

Disposal

 

of

 

Electronic

 

Waste

 

As

 

with

 

most

 

electronic

 

products,

 

this

 

equipment

 

must

 

be

 

disposed

 

of

 

in

 

an

 

environmentally

 

friendly

 

way,

 

and

 

in

 

accordance

 

with

 

existing

 

regulations

 

for

 

electronic

 

waste.

 

Please

 

contact

 

your

 

FLIR

 

Systems

 

representative

 

for

 

more

 

details.

 

 

Содержание CM72

Страница 1: ...USER MANUAL FLIR CM72 and CM74 CLAMP METERS CM72 600A True RMS AC Clamp Meter CM74 600A True RMS AC DC Clamp Meter...

Страница 2: ...on Switch 9 4 3 Function Buttons 9 4 4 Display Icons and Indicators 10 5 OPERATION 12 5 1 Powering the Meter 12 5 1 1 Auto Power Off 12 5 2 Auto Manual Range Mode 12 5 3 HOLD Mode 12 5 4 Voltage and C...

Страница 3: ...17 5 5 Resistance Measurements 18 5 6 Continuity Test 18 5 7 Capacitance Measurements 19 5 8 Diode Test 20 6 MAINTENANCE 21 6 1 Cleaning and Storage 21 6 2 Battery Replacement 21 7 SPECIFICATIONS 22 7...

Страница 4: ...nced herein are used for identification only and are the property of their respective owners 1 2 Quality Assurance The Quality Management System under which these products are developed and manufactur...

Страница 5: ...isconnect the test leads from the circuit that you did a test on before you change the range If you do not do this damage to the instrument and injury to persons can occur Do not replace the batteries...

Страница 6: ...cause damage to the protection This symbol adjacent to another symbol or terminal indicates that the user must refer to the manual for further information This symbol adjacent to a terminal indicates...

Страница 7: ...acklit display Work light Auto Range True RMS AC 600 A capability and selection CM72 Auto Range True RMS AC DC 600 A capability and selection CM74 Auto Range True RMS AC DC 600 V capability and select...

Страница 8: ...utton only CM72 4 Function switch 5 COM negative Probe Input jack 6 Positive Probe Input jack 7 DCA Zero and Inrush button CM74 only Work light button CM72 8 MIN MAX HOLD button 9 AUTO RANGE Button 10...

Страница 9: ...Buttons Select AC or DC in the Voltage Current modes Select Diode or Capacitance Continuity or Resistance Select Hz in the AC Voltage Current FLEX modes Select Auto or Manual range mode see section 5...

Страница 10: ...to range mode Indicates that the meter is in Hold mode Indicates the battery voltage status Indicates that the auto power off function is enabled Indicates that the measured voltage is greater than 30...

Страница 11: ...rad Unit of measure for Capacitance Hertz Unit of measure for Frequency 103 kilo 10 3 milli 10 6 micro VFD mode icon CM74 only DC Zero mode icon CM74 only Inrush current mode icon CM74 only Flex Clamp...

Страница 12: ...wering off Press any button or turn the function switch to prevent the meter from powering off The auto power off time out is then reset To disable auto power off press the MODE button while turning t...

Страница 13: ...n 5 2 Auto Manual range mode 4 Insert the black probe lead into the negative COM terminal and the red probe lead into the positive V terminal 5 Connect the probe leads in parallel to the part under te...

Страница 14: ...aws refer to Figure 5 2 Figure 5 2 Correct and incorrect setup 1 Ensure that the probe leads are disconnected from the meter 2 Set the function switch to the A position 3 To manually select AC or DC p...

Страница 15: ...s the highest AC current reading in the first 100ms period after the trigger point current detection threshold is reached see Fig 5 3 below The current detection threshold is 0 5A for the 60 00A range...

Страница 16: ...HOLD button to access the MIN MAX mode 2 The first screen will be the MIN screen The down arrow will appear indicating MIN mode and the displayed reading will represent the lowest reading encountered...

Страница 17: ...rent measurements made by the FLEX Clamp Adaptor 1 Turn the function dial to the position 2 Connect the Flex Clamp as shown 3 Set the Range of the Flex Clamp Adaptor to match the range of the CM174 4...

Страница 18: ...s the circuit or component under test 5 Read the resistance value on the display Figure 5 5 Resistance and Continuity Measurements 5 6 Continuity Test Warning Do not perform continuity tests before re...

Страница 19: ...the position 2 Use the MODE button to select capacitance function capacitor symbol must be displayed 3 Insert the black probe lead into the negative COM terminal and the red probe lead into the posit...

Страница 20: ...d into the negative COM terminal and the red probe lead into the positive terminal 3 Use the MODE button to select the diode test function The diode indicator will be displayed 4 Touch the tips of the...

Страница 21: ...ted to a circuit remove the probe leads from the terminals and set the function switch to the OFF position before attempting to replace the batteries 2 Unlock and remove the battery compartment cover...

Страница 22: ...o 104 F 30 to 40 C 75 RH 104 to 122 F 40 to 50 C 45 RH Storage conditions 4 to 140 F 20 to 60 C 0 80 RH batteries not installed Dimensions D W L 1 7 3 5 9 5 in 43 mm 89 mm 241 mm Weight CM72 12 8 oz 3...

Страница 23: ...counts when the AC reading is 10 counts CM72 Overload protection 600 V rms CM74 Overload protection 1000V rms Input impedance 10 M 100 pF Lo Z Input impedance 2 5k AC conversion type AC coupled true...

Страница 24: ...me as AC Voltage DCA affected by the temperature and residual magnetism use DCA Zero function to compensate AC conversion type AC coupled true RMS responding calibrated to the RMS value of a sine wave...

Страница 25: ...and 600 A rms CM74 1000Vrms and 600 A rms Trigger Sensitivity 5Vrms for ACV 10Hz 10kHz 15Vrms for ACV 10kHz 60kHz range 4Arms for ACA 10Hz 10kHz 8Arms for ACA 1kHz 10kHz CM74 only Reading will be 0 0...

Страница 26: ...tection 600 V rms CM74 Overload protection 1000 V rms Maximum test current Approx 0 1 mA Maximum open circuit voltage for Approx 1 8 V Maximum open circuit voltage for diode Approx 1 8 V Continuity th...

Страница 27: ...dgt 45 400Hz 300 0 A 3000 A LCD displays 0 counts when the reading is 10 counts Additional accuracy for the Flex function is listed in the FLIR clamp adaptor User Manuals Models TA72_TA74 Table 7 8 Fl...

Страница 28: ...imited Lifetime Warranty are MR7x CM7x CM8x DMxx VP5x not including accessories which may have their own warranty 3 WARRANTY PERIODS For purposes of The Limited Lifetime Warranty Lifetime is defined a...

Страница 29: ...r all packaging and shipping costs FLIR will pay for returning to Purchaser any Product that FLIR repairs or replaces under warranty FLIR reserves the right to determine in its sole discretion whether...

Страница 30: ...tomer Support Technical Support Website http support flir com Technical Support Email T MSupport flir com Service and Repair Email Repair flir com Customer Support Telephone 1 855 499 3662 option 3 to...

Отзывы: