![FLIR CM65 Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/flir/cm65/cm65_user-manual_2305986034.webp)
To access the CM65 Programming Menu, short press the OK button with the
meter ON (or select the Settings function icon as explained in Section 7,
Function Icons
). Use the up/down arrow buttons to scroll the Programming
Menu list and press OK at a parameter to open it. See the details below:
•
APO
: Auto Power OFF utility.
1. Press OK at the APO parameter to open it.
2. Use the up/down arrow buttons to change the value of the flashing digit.
3. Use the left/right arrows to select a digit for editing and use the up/down
arrows to change it. The APO setting range is OFF (no APO function)
and 1 to 99 minutes.
4. Press OK to confirm the new APO time.
5. Use the up/down arrows to select a new parameter to edit, or press the
Return button to exit to the normal operating mode.
•
FILE
: Data Log file list.
1. Press OK at the FILE parameter to open it. If Data Log records are
saved, the list will appear here.
2. Use the up/down arrows to scroll through the data log list.
3. Press OK at a list to open it.
4. When a list is open, the Function Icons for
file delete
,
file transmit
, and
file open
will appear on the bottom of the display. Note
that the file transmit icon will only appear if Bluetooth® is enabled in
this Programming Menu (BLE), the Bluetooth® button is pressed so
that the Bluetooth® icon is shown on the CM65 display, and the CM65
is paired with a mobile device. For details, see Section 6 for
Bluetooth®
and Section 7 for
Function Icons
.
5. Press the Return button to return to the main menu list. Press again to
return to the normal operating mode or use the arrows to select another
menu parameter.
•
TIME
: Set the date and time.
1. Press OK at the TIME parameter to open it.
2. Use the up/down arrows to set the year.
3. Press OK to confirm.
4. Use the up/down arrows to set the month.
5. Use the right arrow to move to the date digits, use the up/down arrows
to set the date.