![Flintec FT-10 FILL Скачать руководство пользователя страница 90](http://html1.mh-extra.com/html/flintec/ft-10-fill/ft-10-fill_technical-manual_2305534090.webp)
FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 89 of 131
13.
E
THERNET
TCP/IP
(
ONLY
FT-10
FILL
EN)
Ethernet output of FT-10 FILL EN is programmable to BSI command set, Continuous data output, Fast
continuous data output, odbus TCP/IP High-Low, Modbus TCP/IP Low-High. The first three data structures
can be found in the related sections indicated in the table below.
You can find below the difference of Low-High and High-Low data formats and some companies using these
formats.
Data Format
Description
Company samples
BSI Command set
Refer to Page 74
Continuous
Refer to Page 72
-
Fast Continuous
Refer to Page 73
-
Modbus TCP High-Low
Modbus TCP interfacing.
Refer to Page 91.
Interfacing with PLC.
Modbus TCP Low-High
Modbus TCP interfacing.
Refer to Page 91.
Interfacing with PLC.
Table 13.1
- Ethernet output interfacing
You can communicate with the controller after programming Ethernet TCP/IP and Modbus TCP related
parameters [
03-
] on Page 31.
[03-] Ethernet (Only FT-10 FILL EN)
This sub-block includes the parameters related with the Ethernet of FT-10 FILL controller.
[030 5 ] Data Format
0 : No data transfer.
1 : Continuous data output
(Page 72)
2 : Print mode
(Parameter [040] (Page 32)
3 : BSI command set
(Page
4 : Modbus TCP High-Low
( * )
(Page 91)
5 : Modbus TCP Low-High
( * )
(Page 91)
6 : Fast continuous mode
(Page 73)
( * ) Warning :
Parameter [ 000 ] and [ 010 ] should not be selected Modbus RTU.
[031 001] Device Address
The address of FT-10 FILL will be entered between 01 to 255.
[032 ] IP Address
The IP address will be entered as ” aaa.bbb.ccc.ddd ”. Default is “192.168.16.250”.
For changing the IP address, press the <
Tare
> key and enter the first 3 “a” digits of the IP address.
Press <
Enter
> key to access the following “b”, “c” and “d” address entries.
Press the <
> key to access the next parameter.
[033 ] Subnet Mask Address
The IP address will be entered as ” aaa.bbb.ccc.ddd ”. Default is “255.255.255.000”.
For changing the IP address, press the <
Tare
> key and enter the first 3 “a” digits of the IP address.
Press <
Enter
> key to access the following “b”, “c” and “d” address entries.
Press the <
> key to access the next parameter.