PUMP PRIMING AND STARTUP

4.  Check to be sure water in the cavity of pump 

stays constant. If water level goes down, it 

could indicate a leak in the foot valve, check 

valve or suction pipe.

Water Level

Check for leaks

Suction

pipe

4

5.  Once pump is filled, wrap the pressure 

gauge or discharge tee plug and vent plug 

threads with thread tape and thread into 

pump. Tighten with wrench.

NOTE: Before turning on breaker, open several 

outlets or faucets to allow water flow during 

priming.

Vent Plug

Pressure

Gauge or

Discharge

Tee Plug

5

20

20

20

20

Breaker Box

6.  Turn on breaker to start pump.

  IMPORTANT: 

 If the pump hums instead 

of pumping or turns off repeatedly, shut pump 

off immediately. Check voltage. Make sure 

your incoming voltage matches the pump 

wiring voltage. See PUMP ELECTRICAL 

CONNECTIONS.

  IMPORTANT: 

 If pump fails to prime within 

five minutes:

Turn power off at the breaker box and check 

all pipe connections for leaks. All connections 

must be water and air tight in order for pump to 

operate.

7.  Check suction pipe for any sagging. Support 

suction pipe in a straight line to the pump.

NOTE

: Look for leaks or a milky color in the 

discharged water, which indicates an air leak. 

Re-prime if necessary, following steps 1 through 

6 above. Reset breaker at the breaker box. All 

connections must be water and air tight in order 

for pump to operate.

6

To Pressure

Tank

Foot Valve

1 in. 

Discharge Pipe

1-1/4 in. 

Suction Pipe

Well

7

Содержание FJ05S

Страница 1: ...Copyright 2018 Flint Walling All rights reserved 1 SHALLOW WELL JET PUMP MODEL FJ05S 1 2 HP FW1642 C ATTACH YOUR RECEIPT HERE Serial Number Purchase Date flintandwalling com...

Страница 2: ...s or 230 volts 60 Hz Pump is set by the factory to run on 230 volts Maximum water temperature 77 F 25 C Individual branch circuit required 15 Amp minimum Discharge connection 1 in NPT Suction connecti...

Страница 3: ...ase hot surfaces or chemicals ELECTRICAL SHOCK ALERT Wire motor to correct supply voltage See motor nameplate and wiring diagrams and check voltage of power supply ELECTRICAL SHOCK ALERT Unit must be...

Страница 4: ...uct make sure all parts are present If any part is missing or damaged do not attempt to assemble the product Compare parts to package contents list Estimated Installation Time 2 hours Tools Required f...

Страница 5: ...vertical distance from the lowest level of the water to the pump intake Pump will move water as long as it is within 25 vertical ft of the water source Horizontal Distance The horizontal distance is...

Страница 6: ...it and add another 1 4 turn to ensure proper seal 1 1 1 4 in male PVC adapter 1 1 4 in Foot valve Pipe And Fittings 3 Use galvanized steel or NSF PW Schedule 40 PVC pipe and fittings This material is...

Страница 7: ...1 1 4 in PVC pipe Pipe clamp 25 ft maximum Water level 5 ft minimum 4 IL1535 Approx 12 in Well Seal 4 Remove the pipe clamp and slide a well seal not included over the PVC pipe and onto the well casin...

Страница 8: ...opening in the front of pump 8 1 1 4 in PVC Pipe Well 8 Using 2 step PVC system attach 1 1 4 in PVC pipe and couplings as needed to connect the 1 1 4 in male PVC adapter to the 1 1 4 in PVC elbow att...

Страница 9: ...adapter not included and thread the adapter into the discharge tee PUMP TO TANK CONNECTION DISCHARGE PIPE Pressure Gauge or Pipe Plug with Bushing 2 Install a 1 in MPT x 1 4 in FPT galvanized bushing...

Страница 10: ...n not included and continue with pipe and 3 4 in x 3 4 in x 3 4 in tee not included Glue 1 in x 3 4 in Reducer Bushing 1 in Pipe Glue Tee Union 3 4 in pipe Reducer bushing 3 4 5 IL1366 Glue Elbow 2 At...

Страница 11: ...er cable from coming in contact with sharp objects All wiring should be performed by a qualified electrician in accordance with the National Electric Code and local electric codes Connect the pump to...

Страница 12: ...ng 230 V Setting 2 To connect the pressure switch remove the switch cover and insert an electrical wire strain relief not included into the opening in the side of the pressure switch IL1376 Wire from...

Страница 13: ...s the suction pipe will be filled in addition to the cavity of pump 1 Remove pipe plug or pressure gauge not included at the top of the discharge tee and the vent plug in front of the discharge tee Ve...

Страница 14: ...p IMPORTANT If the pump hums instead of pumping or turns off repeatedly shut pump off immediately Check voltage Make sure your incoming voltage matches the pump wiring voltage See PUMP ELECTRICAL CONN...

Страница 15: ...odes ordinances and good trade practices and e the unit is used for purposes other than for what it was designed and manufactured RETURN OF WARRANTED COMPONENTS Any item to be repaired or replaced und...

Страница 16: ...structions page 13 2 Leak in suction line 2 Repair or replace Pipe dope all threads 3 Discharge line is closed and priming air has nowhere to go 3 Open several outlets or faucets during priming proced...

Страница 17: ...eplacement parts call our customer service department at 1 800 742 5044 7 30 a m 5 p m EST Monday Friday PART DESCRIPTION PART NO B O rings Nozzle Venturi Kit 023735 C Diffuser 023707 D Impeller 02370...