16.03.2021 | V1.04
-14-
Installation / Operation Manual
System Control Unit
Figure 5-1: SCU Sub-D connector pin numbering
5.1
Lane A / Lane B / Lane C Connector
The Lane A Connector carries the power supply pins of the SCU (Pins 1 and 5) and Display CAN Lane A
(Pins 2 and 7). Table 5-3 specifies its pinout. Reverse polarity and voltage surge protection are
implemented on the Lane A connector, therefore power must be supplied there. Install a 3 A circuit
breaker or quick fuse in the positive supply line. For CAN wiring, use shielded twisted pair cables with
an impedance of 120
Ω. Do not connect
either of the CAN Ground Pins available on the two Harness
Interface Connectors. Since termination resistors are built into the ECU as well as the SCU, no
additional resistors are necessary.
Pin Number
Signal Name
Function
1
PWR_IN
positive SCU power supply
2
CANL_A
CAN Low, connect to HIC A, Pin 5
3
EXT_PWR_ACT
do not connect
4
EXT_DIN2
do not connect
5
AC_GND
negative SCU power supply, ground
6
EXT_DIN0
do not connect
7
CANH_A
CAN High, connect to HIC A, Pin 6
8
EXT_DIN1
do not connect
9
LS_OUT1
do not connect
Table 5-3: Lane A pinout
The Lane B Connector carries the second Display CAN Lane of the ECU on Pins 2 and 7. This setup
guarantees full redundancy of all data paths to the SCU. Table 5-4 specifies its pinout.