Rev:
K
Revision Date:
05/23/2014
Page 12 of 21
MAN
– FD201CV-LP VER HD
Command sets for controlling the monitors with serial numbers starting w/
12XXXXXXXX (10 digits) and above:
Commands
Length
CMD
Index
Set ID
Data
Check Sum
Power On
0x08
0x12
0x9C
0x00
0x00
0x01
0x01
0x48
Power Off
0x08
0x12
0x9C
0x00
0x00
0x00
0x01
0x49
HDMI 1
0x08
0x12
0x8E
0x00
0x00
0x00
0x01
0x57
HDMI 2
0x08
0x12
0x8E
0x00
0x00
0x01
0x01
0x56
DVI
0x08
0x12
0x8E
0x00
0x00
0x02
0x01
0x55
VGA
0x08
0x12
0x8E
0x00
0x00
0x03
0x01
0x54
S-Video
0x08
0x12
0x8E
0x00
0x00
0x04
0x01
0x53
Composite
0x08
0x12
0x8E
0x00
0x00
0x05
0x01
0x52
Auto
0x08
0x12
0x7E
0x00
0x00
0x00
0x01
0x67
Full Screen
0x08
0x12
0x7E
0x00
0x00
0x01
0x01
0x66
16:9
0x08
0x12
0x7E
0x00
0x00
0x02
0x01
0x65
4:3
0x08
0x12
0x7E
0x00
0x00
0x03
0x01
0x64
1:1
0x08
0x12
0x7E
0x00
0x00
0x04
0x01
0x63
Below are the command sets to control the power, source selection, and backlight brightness. The 13
characters below are shown in hexadecimal. The communication system must be set up for 19200
Baud, no parity, 8 bits of data, and 1 stop bit.
Notes:
1.
The first nine characters will remain the same for any command.
2.
For connecting multiple monitors to one controller; the number can be set to 0x00 to control all
monitors at once, 0x01 to control monitor number 1, 0x02 monitor number 2, and so on until
0x63 for monitor number 99.
3.
The number will change depending on command.
4.
Identifier for the group of commands.
5.
All commands need to end with a Carriage Return
The RS-485 connector carries information between the Infrared received and the LCD
controller board. Any connections to the RS-485 bus must be tolerant to the existing control
signals. Devices connected to the RS-485 Bus should not send traffic that interferes with the
existing RS-485 messages.