Document Number:
MAN - FD141CV-TS-HDSDI
Rev:
C
Revision Date:
03/29/11
Page 7 of 15
Power and Ground Wiring
This is a 28VDC monitor that requires 1.5 amps of power to operate. To operate properly
this monitor requires an input voltage of 28VDC.
The rated current of the equipment and associated voltage drop should be taken into
consideration when selecting wire gauge. The following example is based on an install with
a 28VDC power system and a total of 50 feet of wire between the circuit breaker, monitor
and ground.
Example: 22awg wire has 16.2 Ohms per 1000 feet, this equates to .81 Ohms for 50 feet.
3 Amps of current on .81 Ohms will drop 2.43 Volts.
Resistance of Wire Type M22759/16-**
(** = Gauge)
Gauge (AWG)
Ohms/1000’
24
26.20
22
16.20
20
9.88
16
4.81
12
2.02
10
1.26
8
.70
Also, use short heavy gauge wire and a clean tight connection for ground.
It is the installer's responsibility to understand the product's requirements to install the
product in compliance with industry standards and safety.